IDC 255 Progate Drive Thru Installation Manual
Publication Number: 621057419INS
- 8 -
© 2006, IMI Cornelius Inc.
W
ATER
I
NSTALLATION
To access cold plate water inlets
1.
Remove screws holding attaching lower splash panel to frame and slide panel away from machine.
2.
Use Oetker clamps to secure lines to barbed fittings.
FIGURE 5
FIGURE 6
3.
Use 3/8” tubing capable of handling a
minimum of 120 psi. Approved for food
applications.
4.
Guide water lines from back of machine to
left front and attach to cold plate lines W1
(carbonator water line) and W2 (plain
water or mains water line).
NOTE: W4 is the re-circulation line which is
connected to a remote tower (A&W remote
tower).
5.
Turn on pressure and check for leaks.
FIGURE 7
FIGURE 8 [Note: Shown without TotalFlex 1 (TF 1)]
W1
W2
W4
DETAIL A SCALE 1.500
SEE DETAIL A