FlavorFusion® Training Manual
Publication Number: TP01070
- 18 -
© 2004-2007, IMI Cornelius Inc.
Power cord is
connected but
carbonator pump
does not run.
Carbonator pump motor is disabled.
Check the enable/disable switch on the
carbonator pump terminal box and
enable it, if necessary.
Probes were dry, unit was powered up,
water was not turned on, and
carbonator did not fill.
This results in a 5 minute timeout.
Unplugging the unit and plugging it in
will reset the unit and start the
carbonator pump.
Water service was interrupted for more
than 5 minutes.
Unplugging the unit and plugging it in
will reset the unit and start the
carbonator pump.
Carbonator pump is
short cycling with
every drink drawn
Lower liquid level probe reads “dry”
while upper probe reads “wet”
Check color of leads going to probes.
Black should go to bottom probe and
white to top probe. Reverse if incorrect.
Carbonator tank
overfills, overflows
through relief valve,
and pump shuts off
after 5 minutes.
A. Poor electrical connections between
carbonator tank and main control board
A. Check connections at carbonator
tank and at connector J4 on the main
control board.
B. Broken wires between carbonator
tank and main control board
B. Replace wire harness
C. Defective liquid level probes
C. Replace both liquid level probes
Содержание Flavorfusion TP01070
Страница 4: ...FlavorFusion FlavorOverload Training Manual Publication Number TP01070 ii 2004 2007 IMI Cornelius Inc...
Страница 14: ...FlavorFusion Training Manual Publication Number TP01070 10 2004 2007 IMI Cornelius Inc SYSTEM PLUMBING DIAGRAM...
Страница 24: ...IMI Cornelius Inc www cornelius com...