Energize6 Service Manual
Publication Number: 621058457SER
- 8 -
© 2012, IMI Cornelius Inc.
Figure 7.
Table 3.
LED
Warning
Required Action
Green
ON
Voltage OK
None
OFF
No Power
Check/Reset Power
Blinks
HIGH or LOW Voltage
Check/Reset Power
Yellow
ON
CO
2
Pressure Low
Check/Replace CO
2
Supply
Red
ON
or
Blinks Slow
Time Out Carbonator
Water Supply Pressure Low
Reset Power, If it Remains On, Call
Service
Check/Replace Water Filter
Blinks Fast
Over Temp/Motion Controller
Check/Reset Power
Red/Green
Red/Green
Blinks
Main Controller
Call Service
Compressor
Recirculation
Carbonator Tanks
(Not Used)
Recirculation
Carbonator Tanks
Master Controller
Slave Controller