Ice/Beverage Dispenser Installation Manual
© 2004-2010, IMI Cornelius Inc.
- 12 -
Publication Number: 620917902INS
Contact your local syrup or beverage equipment distributor for additional information and troubleshooting
of beverage system.
FLAVOR SYRUPS DO NOT DISPENSE
A. No 24 volt power to PC board.
B. No CO2 pressure.
C. Empty syrup tank.
D. Kinked tubing.
E. Clogged inner nozzle.
F. Defective PC board.
G. Defective harness from keypad.
H. Defective Flow control.
I. Defective solenoid harness.
J. Defective keypad.
FLAVOR DISPENSES FOR MORE THAN 1 SECA. Dip switch settings on control board incorrect.
B. PC board defective.
C. Defective flow control.
FLAVOR DISPENSES MORE THAN .5 OZ
A. Dip switch settings on control board incorrect.
B. Flow control incorrectly set.
C. PC board defective.
D. Defective flow control.