CR R134a Range

 

 

 

Manual operation undercounter cooler 

CR R134a 

Page 8 

 

Cornelius Deutschland GmbH 
Document no: TD1004600EN 
Version A, 24.09.2019, Index 0 

Caution! 

 
Component damage due to freezing liquids 
 

Ambient temperatures that are below freezing will lead to the freezing of any water or cleaning agent 
residue remaining inside the unit. This will lead to damage to internal components. 

 

Before shipment, storage or relocation of the unit, the unit is to be cleaned and the cleaning solution is 
to be fully drained from the unit. 

 
 

2.2 

Disposal 

 
Disposal of the units must be carried out in compliance with the applicable local and/or national and 
international regulations. Units must not be disposed of with household waste. 
If the unit contains fuels or lubricants in liquid, paste-like or gaseous form, such as oil, grease, cooling agents 
etc., such fuels or lubricants are to be collected using appropriate measures and disposed of in compliance with 
the applicable local and/or national and international regulations. Such fuels or lubricants must always be 
prevented from seeping into the ground, the sewage system and any bodies of water, and must always be 
prevented from entering the atmosphere. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CR 11

Страница 1: ...CR R134a Range Manual Operation...

Страница 2: ...n status Index 0 Protection notices in accordance with DIN ISO 16016 2002 5 The reproduction distribution and utilization of this document as well as the communication of its contents is prohibited un...

Страница 3: ...quirements 9 3 1 Installation Sites 9 3 2 Electrical Connections 9 4 Installation 9 4 1 Connection of Soda water Still water Premix beverages and Postmix syrups 9 4 2 Connection of Beer 9 4 3 Connecti...

Страница 4: ...s components may cause personal injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability Improper use of the unit is prohibited The following in particular is regarde...

Страница 5: ...owledge of relevant standards laws regulations accident prevention regulations generally accepted safety related regulations and operating conditions to be able to perform the required activities as w...

Страница 6: ...formation on occupational safety for the safe operation of dispensing systems as applicable in the respective country of installation Notice o Make sure that the cable markers are not removed from the...

Страница 7: ...sture entering a unit as well as certain weather conditions e g condensate forming at the unit sunlight will cause damage to the unit and its components Protect the unit and its components by storing...

Страница 8: ...e fully drained from the unit 2 2 Disposal Disposal of the units must be carried out in compliance with the applicable local and or national and international regulations Units must not be disposed of...

Страница 9: ...The unit must be installed by a trained service technician Please take care that the socket for the unit is always accessible If the power supply cable to the unit is damaged it has to be replaced by...

Страница 10: ...he agitator motor Reference Use for this a suitable funnel and filler tube To prevent algae from forming in the water add the disinfectant Molco PN 14 9670 150 The 150 ml container of disinfectant is...

Страница 11: ...nly by operator Check whether carbon dioxide is open Check the beverage lines for leaks Only a visual inspection is possible If liquid escapes call a service technician Check the CO2 lines for leaks b...

Страница 12: ...e of beverage X X X Before and after a pause of more than 1 week X X X X Weekly X Every 2 weeks X Every 3 months X X Every 12 months X 6 2 Cleaning and Disinfection Procedure before use In order to ac...

Страница 13: ...ched with CO2 Connect container with fresh basic material Beverage foams at all taps CO2 pressure too high Set pressure All syrups Connect container enriched with CO2 with fresh basic materials All be...

Страница 14: ...604 W 800 W 1512 W 1512 W 2400 W 2400 W 2400 W Air flow 160 m3 h 300 m3 h 570 m3 h 570 m3 h 1700 m3 h 1700 m3 h 1700 m3 h Compressor output 245 W 395 W 684 W 684 W 1437 W 1437 W 1437 W Weight of ice b...

Страница 15: ...R134a Range Manual operation undercounter cooler CR R134a Page 15 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 9 Flow Chart 9 1 Premix and Beer units 9 2 Postmix un...

Страница 16: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 16 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 10 Circuit Diagram...

Страница 17: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 17 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 11 Declaration of Conformity Konformit tserkl rung...