NOZZLE DIFFUSER REMOVAL
NOTE:Diffuser cleaning or sanitizing is recommended twice weekly.
Table 9.
Step
Action
Figure
1
Turn nozzle clockwise (left), Than pull down,
the diffuser will stay in position (it is keyed only,
fits one way).
Figure 21.
2
Pull diffuser down. Clean with warm soapy
water then sanitize and reinstall.
NOTE:Do not soak for more than 2 minute.
Seal may warp
Figure 22.
3
Remove Seal from Diffuser by inserting thumb
into center and pulling against the 2 surfaces
to pull the seal away from the diffuser.
Figure 23.
4
Line up the locating notches on inner 10circle
of both the Seal and Diffuser. Push the Sili-
cone Seal into the Diffuser until it sits flat.