Cornelius 318569000 Скачать руководство пользователя страница 1

E

IMI Cornelius Inc; 1999–2003

February 9, 1999

569000261

Revised: October 9, 2003

IMI CORNELIUS INC  

g

  One Cornelius Place   

g

  Anoka, MN 55303-6234

Telephone (800) 238-3600                                      Facsimile (800) 535-4231

INSTALLATION INSTRUCTIONS

 DISPENSING VALVES KEYED LOCK-OUT SWITCH KIT (P/N 569000262)

ON

 VANTAGE POST-MIX DISPENSERS

Read and understand these instructions thoroughly before installing this Dispensing Valves Keyed Lock-out
Switch Kit (P/N 569000262) on the Post-Mix Dispensers. The purpose of the Keyed Lock-Out Switch  is to shut
off electrical power to the dispensing valves to prevent dispensing of product. Retain these instructions as part
of your equipment manual.

LOOSE-SHIPPED PARTS

Note: Only qualified personnel should install this Kit.

Unpack and inspect kit. Make sure items are present and in good condition.

Table 1. Loose-Shipped Parts

Item

No.

Part No.

Name

Qty

1

560003869

Wiring Harness

1

2

560003870

Template, Hole Drilling

1

3

318948000

Lock Key

1

4

318949000

Hex Nut

1

5

318569000

Key-Lock Switch

1

6

569000261

Installation Instructions

1

KIT INSTALLATION

WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure
Dispenser is disconneced from power source before attempting to install this kit.

1. Disconnect electrical power from the Dispenser

2. Remove hood from the Dispenser, then lift hood straight up off the Dispenser for access to the transformer

on the refrigeration deck.

3. Refer to Figure 1 for location of hole to be drilled in the Dispenser hood for installation of the KEY-LOCK

SWITCH (item 5).

4. Place TEMPLATE, HOLE DRILLING (item 2) in position on Dispenser hood as shown in Figure 1.

5. Drill hole in Dispenser hood as indicated on the hole drilling template, then remove template from the hood.