Use and Maintenance Manual – 08/2018 Rel. 4
Page 28
Apply the weights displayed by the machine at the indicated positions and then run a second test spin. Normally, the weights should
be applied at the 12 o’clock with the exception of special programs for ALS1 and ALS2 aluminum.
Table T16.1: Program types available
Program Type Wheel
material
Weight position along the rim
selection
Automatic
acquisition
Notes
STD
Steel
Default
2 sensors
Default at power on
ALS1
Aluminum
Default inner weight, outer
weight provided by user
1 sensor
ALS2
Aluminum
Provided by user
1 sensor
16.1 Program Type Selection (Program Type)
The programs can be selected in NORMAL mode as described below:
Ph.
1
When starting (by default) the
“STANDARD” program is set on.
Based on the active Program Type, the Program Type status and the position of the imbalance weights are displayed on the icon
band.
Note: the selection of the Program Type STD removes the visualization of Static Imbalance.
Acquisition through a sensor only uses the Distance/Diameter sensor.
The position of the balancing weights along the section of the rim in the various Program Types is shown in figure F16.1.
Figure F16.1: Position of the weights in the various Program Types along the section of the rim
The angular position of the balancing weights in the various Program Types is shown in table T16.2.
Содержание TOUCH MEC 100
Страница 1: ...WHEEL BALANCERS TOUCH MEC 1000 USE AND MAINTENANCE MANUAL UK 08 2018 Rel 4...
Страница 2: ......
Страница 56: ...Use and Maintenance Manual 08 2018 Rel 4 Page 51...