Figure 8: TigoBridge A1 and Cradle 

Figure 9: TigoBridge A1 Mounted on the Cradle 

 

Cradle Mounting Guidelines: 

1.  Secure the cradle on the flange (or machine or any other surface) using M3 screws or cable ties. 

2.  Mount the TigoBridge A1 onto the cradle by pushing it in. 

3.   Pull the TigoBridge A1 from the cradle to unmounting it. 

6. 

Configuration & Setup 

Commissioning Prerequisites:  

 

TigoEngine software installed and running on PC.  

 

TigoMaster/TigoGateway successfully connected to PC.  

Installation:  

1.  Plug a 24VDC power supply to TigoBridge A1 M12 power connector via M12 cable. 

2.  The Power LED lights up green. If it does not, check the power connection. 

3.  Once the power supply is connected, a reset cycle occurs. The reset cycle duration is a few 

seconds and displays a red green blue color sequence.  

4.  Once the reset cycle is complete, the status LED alternates between magenta and yellow.  

5.  Plug the TigoBridge A1 to an IO-Link device (sensor/actuator).  

Note

, if TigoBridge A1 cannot connect directly to the device, you may use an M12 cable. Once 

successfully connected the Status LED alternates between Magenta and Green.  

6.  Open the TigoEngine and scan the network for the IO-Link Wireless TigoBridge A1.   

 

Содержание TigoBridge A1

Страница 1: ...Copyright 2021 CoreTigo Ltd TigoBridge A1 User Manual CoreTigo TigoBridge A1 USER MANUAL...

Страница 2: ...TigoBridge A1 User Manual Copyright 2021 CoreTigo Ltd Page 2 of 23...

Страница 3: ...ion 8 4 2 Overview 8 4 2 1 Functional Diagram 9 4 3 LEDS 9 4 3 1 Power LED 9 4 3 2 Status LED 10 4 4 Pair by Button 10 4 5 Electrical Wiring 10 4 6 Electrical Connection 11 5 Mounting 11 5 1 TigoBridg...

Страница 4: ...c Diagram 11 Figure 7 Cradle Dimensions 11 Figure 8 TigoBridge A1 and Cradle 12 Figure 9 TigoBridge A1 Mounted on the Cradle 12 Figure 10 TigoEngine Scanning Mode 13 Figure 11 TigoEngine Pairing Proce...

Страница 5: ...igo Ltd Page 4 of 23 Acronyms and Abbreviations Acronyms and abbreviations used in this document are listed in this table Symbol Meaning FW Firmware HW Hardware IF Interface IOLW IO Link Wireless LED...

Страница 6: ...ure 1 TigoBridge A1 References TigoEngine User Manual TigoMaster 2TH User Manual 1 1 Structure The sections of this user manual build on one another 1 2 Typographical Conventions Enumerations are show...

Страница 7: ...ode NEC NFPA 70 Clause 725 121 and Canadian Electrical Code CEC Part I C22 1 2 3 Intended Use The TigoBridge A1 is an IO Link Wireless Class A Bridge with an IP67 enclosure The TigoBridge A1 is intend...

Страница 8: ...TigoBridge A1 is implemented based on the IO Link Wireless standard for W Bridge devices TigoBridge A1 is part of an IO Link Wireless environment It communicates with an IO Link Wireless master There...

Страница 9: ...ing an M12 cable TigoBridge A1 can be connected to an IO Link Wireless Master by TigoEngine Integrated web server tool or PLC Each IO Link Wireless master can operate up to 16 TigoBridges A1 4 2 Overv...

Страница 10: ...igure 4 TigoBridge A1 Functional Diagram A Device Connector B Pairing Button C Power Supply Connector D Power LED Green E Status LED RGB 4 3 LEDS Figure 5 TigoBridge A1 LEDs A Status LED RGB B Power L...

Страница 11: ...y button is used to replace existing TigoBridge A1 with a new one The TigoBridge A1 must be powered off to assure that the TigoMaster disconnects before installing a new TigoBridge A1 Pairing Button c...

Страница 12: ...5 Mounting TigoBridge A1 should be mounted safely and securely next to the device to which it is connected TigoBridge A1 can be mounted with or without the cradle accessory 5 1 TigoBridge Cradle The...

Страница 13: ...onnected to PC Installation 1 Plug a 24VDC power supply to TigoBridge A1 M12 power connector via M12 cable 2 The Power LED lights up green If it does not check the power connection 3 Once the power su...

Страница 14: ...ted TigoBridge A1 Select an empty port on the Master side and click Pair Figure 11 TigoEngine Pairing Process 8 When the pairing process is complete the TigoEngine Port Mode should indicate OPERATE Th...

Страница 15: ...tton on the TigoEngine interface and repeat the instructions to unpair it Once unpaired the TigoBridge A1 status LED alternates between magenta and green Figure 14 Unpair Button 7 Firmware Update Firm...

Страница 16: ...perational Alternating Blue and Green Alternating Magenta and Green Non Operational Alternating Blue and Yellow Alternating Magenta and Yellow Alternating Blue and Green fully Operational both IO Link...

Страница 17: ...t the interference at his own expense 9 3 Modification Statements FCC Warning Modification statement CoreTigo LTD has not approved any changes or modifications to this device by the user Any changes o...

Страница 18: ...y RF Exposure rules This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Le pr sent appareil est conforme l exposition aux radiations FCC ISED d fi...

Страница 19: ...ces LEDs IO Link RGB three color LED Power Green color LED Button Pairing external push button Connectors Input connector Plug M12 A coded power Connector o Pin number 1 Input L Power supply o Pin num...

Страница 20: ...0068 2 27 Bumps IEC 60068 2 27 TigoBridge A1 should be supplied from a limited Class 2 power supply or via overcurrent protective device fuse breacker etc rated 4A max Over current protection on L For...

Страница 21: ...Copyright 2021 CoreTigo Ltd Page 20 of 23 Immunity EN 61000 6 2 o EN31000 4 2 Electrostatic discharge o EN61000 4 4 Fast transients burst o EN61000 4 5 Surge immunity o EN61000 4 6 Conducted immunity...

Страница 22: ...TigoBridge A1 User Manual Copyright 2021 CoreTigo Ltd Page 21 of 23 11 Customer Support For any issue question or to report a bug contact support coretigo com...

Страница 23: ...A Part Number Part number CT221 0057 03 Generation 2 Product Identifier 2 Product Type 1 Protocol 0057 Characters Identifier of Features Version 03 CT GXY ZZZZiii vv G X Y ZZZZ iii vv Generation Prod...