User and Maintenance Manual
“E” Failsafe caliper brake
Model E4N-ID
Date: 2013/07/01
Revision: 1
www.coremo.it
Page
10
of
14
Personnel assigned to these operations must take special care, working cautiously
when bleeding the circuit, wearing suitable PPE such as gloves, goggles and safety
footwear and taking any other precautions necessary before proceeding.
11.
BEDDING-IN:
The initial braking torque may be from 30% to 50% less than the rated value until
the brake lining adjusts to the disc.
8.
Operation
8.1.
Power supply of the safety component
For the correct operation of the brake the control pressure must not exceed 100 bar while the
minimum opening pressure must not be less than 60 bar. Use mineral oil SAE/SO 46.
The technical department of COREMO OCMEA can provide information, suggestions and
assistance for correct application and use of the brake.
8.2.
Improper use
The products considered here must be used exclusively as described in Chapter 5 of this
manual. Any other use is to be considered improper. The manufacturer declines all
responsibility for damage caused by erroneous or unreasonable use of the product.
Use of the product for purposes other than those stated in this manual may
compromise any aspect of safety.
9.
Maintenance and cleaning
TUTTI I TIPI DI INTERVENTO SUL FRENO DEVONO ESSERE EFFETTUATI A MACCHINA
FERMA.
Staff assigned to this work must wear suitable PPE such as gloves and safety footwear and take
any further precautions necessary to ensure adequate protection and prevent injury. Failure to
follow the instructions given for maintenance and cleaning of the product may compromise
personal safety and cause damage to equipment and machinery.