CorDES Proprietary Information
12
Front Panel
1GbE PHY
PORT
Default
*IP.Port#
Rear Panel
Connector
ECU[0]
Connection
ECU[2]
Connection
PT[0]
64000
PT[0]
J3
PT[0]
64001
PT[1]
J5
PT[1]
64002
PT[2]
J3
PT[1]
64003
PT[3]
J5
CT[0]
64004
CT[0]
J4
CT[0]
64005
CT[1]
J6
CT[1]
64006
CT[2]
J4
CT[1]
64007
CT[3]
J6
Table 4-2 CDNA-041G Default mapping of Front Panel PHY to Rear Panel Connectors
•
NOTE: *Default IP.Port# can be changed by HMI or CLI.
The Front Panel has 4x PHY ports, each with a unique programmable IP address. Each PHY
has two IP Port #’s associated with it (programmable) to allow mapping of two logical data
channels to each physical port as shown in the above table.
4.3
Power On
To power on the CDNA-041G
1. Verify all connections are secure.
2. Press the power panel on the front of the chassis and verify the installed hardware
powers up.
4.4
Configuring the ECU Data Interfaces
The CDNA unit interfaces to the ECU data interfaces using the LVDS interfaces in the File
Transfer mode setting. The ECU interface should be configured as shown in the table below
prior to passing traffic through the units.
Parameter
Setting
Personality
Gryphon
Plain Text Interface
Use CTIF
Cipher Text Interface
LVDS
CT Data Format
NRZ-L
Clock Source
Terminal Timing
PT Data
Binary