background image

Water Pump not Included.

Water Pump not Included.

SPECIFICATIONS

PARTS DIAGRAM

HOSE LOCK NUT

O-RING GASKET

QUARTZ HOUSING

UVC LAMP

PLUG

FLAT O-RING

MAIN

BODY

O-RING

TANK

BRACKET

TURBO-TWIST 

BRACKET

HOSE BARB

ADAPTER

HOSE LOCK NUT

SUCTION

CUP

THREADED-CAP

INSTRUCTIONS

Always disconnect the unit from the power supply before 

installing the Turbo-Twist.

The Turbo-Twist provides superior aquarium health and

appearance by eliminating most harmful microorganisms.

Set-up and positioning

Adjusting the hose barb 
inlet and outlet.

The hose barbs can be 
positioned in four different locations 
to facilitate connections to other
applications.

QUARTZ SLEEVE

(PICTURE 1)

QUARTZ HOUSING

QUARTZ

HOUSING

MAIN

BODY

MAIN BODY

(PICTURE 2)

(PICTURE 3)

(PICTURE 4)

(PICTURE 5)

Lift the red safelock and unlock the
quartz housing.  (Picture 1)

Carefully twist the quartz housing
and the main body opposite of each 
other.  (Picture 2)

Combine the main body with the quartz 
housing and rotate according to the 
arrowhead "close".  (Picture 4)

Press in the red safelock and the UV
Sterilizer is now ready to install.  
(Picture 5)

The quartz housing can now be 
rotated 360

o

.  (Picture 3)

Adjust the orientation of the hose 
barb and set the main body into the 
quartz housing.

HOSE
BARB
OUTLET

HOSE
BARB INLET

Article

Turbo-Twist 3x UV Sterilizer

UV Lamp

9 watt

Rated Voltage

AC120V

Rated Cycle

60Hz

Rated Power

10.2 watt

Wavelength of UV Radiation

253.7mm

Life of UV Lamp

Approx. 8000 hours

Aquarium Volume

Treats up to 125 gallon saltwater or freshwater aquariums

Flow Rate

100-200 gallons per hour

Size of O-ring

Inner 12/outer 16mm, inner 16/outer 22mm

Cord Length

Approx. 9 ft.

Irradiation of UV Radiation

9,580   W/cm

2

 (value @ 20mm distance from the UV lamp)

O-RING

HOSE BARB

ADAPTER

LAMP ON INDICATOR

Содержание Turbo-Twist 3x

Страница 1: ...and unlock the quartz housing Picture 1 Carefully twist the quartz housing and the main body opposite of each other Picture 2 Combine the main body with the quartz housing and rotate according to the arrowhead close Picture 4 Press in the red safelock and the UV Sterilizer is now ready to install Picture 5 The quartz housing can now be rotated 360o Picture 3 Adjust the orientation of the hose barb...

Страница 2: ...outside of the aquarium Adjust the tank bracket to secure the Turbo Twist UV Sterilizer Place the O ring on hose barb inlet outlet O RING GASKET HOSE LOCK NUT O RING AQUARIUM HOSE BARB ADAPTER SMALL HOSE LOCK NUT FLEXIBLE TUBING Make sure that the flat O ring gasket is properly positioned inside the threaded cap already installed in unit Screw the threaded cap tightly back into place Note The plug...

Страница 3: ... indicated by the light blue glow emitted through the lamp on indicator The light from the lamp on indicator will not affect the skin or the eye WATER FLOW WATER FLOW MAINTENANCE To ensure superior kill rates of the sterilizer the quartz sleeve should be cleaned periodically PICTURE 1 SAFELOCK Once clean reinstall the quartz sleeve into the main body and push the red safelock into the lock positio...

Страница 4: ...ructions in their entirety before attempting to use this unit Never look directly at the unshielded lamp as the ultraviolet radiation emitted from the lamp can be harmful Do not pull cord to disconnect power Cut off the power and stop using if the unit was submersed or dampened by water Cut off the power immediately if water enters into the Quartz Housing Cut off the power if there is a burning or...

Страница 5: ...55 gph Parasites 121 gph Algae 253 gph Bacteria 44 66 88 110 132 154 176 198 220 242 264 286 SUGGESTED TUBING CONNECTIONS ...

Отзывы: