background image

Rev B | Doc P/N: xxxx 

Copyright © 2018 Coral Detection Systems, all rights reserved.

CORAL MANTA

User Guide

09.07.2018 

Do 
not 
distribute

Содержание MANTA

Страница 1: ...Rev B Doc P N xxxx Copyright 2018 Coral Detection Systems all rights reserved CORAL MANTA User Guide 09 07 2018 Do not distribute ...

Страница 2: ...e E mail Facebook www coraldrowningdetection com info coraldrowningdetection com www facebook com CoralDrowningDetection 2 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 3: ...ails on the far end of the pool can be viewed clearly z z CORAL MANTA requires direct sunlight in order to charge its battery using the built in solar panels z z CORAL MANTA is another layer of safety and does not replace other pool safety means or devices required by local city state country laws z z CORAL MANTA uses computer vision technology to detect drowning Depending on various factors some ...

Страница 4: ...he pool unit and home unit z z The home unit must be plugged into a power outlet inside the house as close as possible to the pool unit Make sure the home unit can be clearly seen and heard inside the home at all times e g when there is background noise music people talking or working electrical appliances z z ADULT SUPERVISION IS REQUIRED AT ALL TIMES NOTE Do not Install the pool unit in a shady ...

Страница 5: ...requires pairing it with a the Coral Drowning Detection app using the app is mandatory only for activating the system NOTE The shape and position of the pool may effect system performances Verify that the pool shape is suitable see Selecting Mounting Position on page 21 and that the pool unit is installed in the proper place see Mounting the Docking Station on page 23 Disclaimers 5 MENU www INTROD...

Страница 6: ...m and includes z z System Layout z z Pool Unit z z Home Unit Introduction Disclaimers 6 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 7: ...d in the pool see Detection Scenarios on page 31 The pool unit transmits alerts to the home unit 1 and to the mobile device 3 as needed z z Home Unit 1 connected to a power outlet in the house communicates with the pool unit over RF direct communication and provides audio and visual indication of the alerts received from the pool unit z z Mobile Application Coral Drowning Detection mobile applicat...

Страница 8: ...ators 2 z z Solar panel 3 z z Docking station 4 z z Connectors 5 z z Battery 6 3 1 5 6 4 2 Introduction Pool Unit 8 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 9: ... sensor 4 provides indication of the water level in the pool and senses activity in the pool z z Camera illumination 5 1 4 3 2 6 5 NOTE The underwater tube is folded and unfolded using an axle 1 When folded a magnet 3 connects to a metal plate 2 to secure the folded tube Introduction Pool Unit 9 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS C...

Страница 10: ...lity degradation z z Steady red there is a significant visibility degradation Battery Level Indicator The pool unit battery level indicator 2 provides the following indications z z Steady green battery is fully charged z z Blinking green battery is partially charged z z Steady red battery charge is below critical level charge immediately z z Blinking yellow battery is charging 5 1 2 3 4 Introducti...

Страница 11: ...Steady blue the pool unit is connected to the Internet z z Blinking blue no Internet connection in the pool unit Introduction Pool Unit 11 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 12: ...smiss button 1 is used to silence the alarm 1 Introduction Pool Unit 12 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 13: ... application applicable only for users who purchased CORAL MANTA without an integrated SIM card 2 4 1 3 NOTE When no DC power is connected the protection cap 2 must cover the socket Introduction Pool Unit 13 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 14: ...dy location The solar panels must be exposed at all times Remove any foreign objects covering the solar panels Introduction Pool Unit 14 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 15: ...tery port in the pool unit The battery handle 3 is used to pull the battery out of its socket The battery level is indicated by the Battery Level Indicator on the pool unit as well as on the home unit 2 1 3 Introduction Pool Unit 15 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distr...

Страница 16: ...ng z z Docking station base 3 z z Screws 1 and nuts 5 two sets of screws and nuts to secure the docking station to the selected corner of the pool z z Docking posts 2 two posts that support the pool unit z z Metal plate 4 attached to the magnet 6 to secure the pool unit when docked 2 1 3 4 6 5 Introduction Pool Unit 16 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLES...

Страница 17: ... the following cases Short high pitch buzz presence in the pool Short loud alarm first indication of a possible drowning danger Longer loud alarm drowning danger is apparent Continuous loud alarm high drowning danger You must get to the pool immediately to pull the person out of the water z z Plug 1 connects to a power outlet inside the house 1 2 3 4 NOTE See section Indicators for a more detailed...

Страница 18: ...ifications on the mobile device The mobile application also enables the user to retrieve images of the pool dismiss alerts and receive notifications of visibility connectivity and battery statuses Introduction Mobile Application 18 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distri...

Страница 19: ...Unit z z Inserting the SIM Card Optional z z Inserting the Battery z z Charging the Battery z z Connecting the Home Unit z z Downloading Coral Drowning Detection Application First Installation Mobile Application 19 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 20: ...on 1 Battery pack 1 Home unit 1 Pool unit charger 1 Docking station mounting guide sheet 1 Accessories pack 1 Quick Start Guide 1 First Installation Opening the box 20 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 21: ... Shortest distance between the home unit and the pool unit distance should not exceed 50 yards z z Mount the pool unit to allow full exposure to sunlight during all or most of the day z z The docking station mounting screws should be anchored see Mounting the Docking Station on page 23 First Installation Selecting Mounting Position 21 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAIN...

Страница 22: ...s on the tube 1 NOTE The water level in the pool must reach between the top and the bottom marks of the pool activity sensor 1 see Underwater Tube on page 9 First Installation Selecting Mounting Position 22 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 23: ...ounting guide sheet is exactly in line with the corner of the pool 3 3 Mark the two spots 5 for drilling holes for the screw anchors 4 Remove the mounting guide 1 5 Drill 4 two 8mm 5 16 holes 4 1 5 3 2 First Installation Mounting the Docking Station 23 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 ...

Страница 24: ...on 3 using two screws 1 and washers 2 1 2 3 4 5 First Installation Mounting the Docking Station 24 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 25: ... 3 on the docking station with the receptors on the bottom of the pool unit 5 Gently press the pool unit down onto the docking station The magnet 1 in the pool unit secures the connection 3 2 1 First Installation Placing the Pool Unit 25 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not ...

Страница 26: ...egrated SIM card This procedure is needed only for customers who purchased CORAL MANTA without a SIM card First Installation Inserting the SIM Card Optional 26 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 27: ...battery into the pool unit Use the handle 1 to push the battery in Once the battery is inserted a short alarm sounds and all LED indicators blink 1 First Installation Inserting the Battery 27 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 28: ...ge the pool unit plug the pool unit charger to the DC IN port 1 on the pool unit and plug the other end to a power outlet 1 WARNING The 110V 220V AC outlet should be as far from the pool as required by your state local laws NOTE It is recommended to fully charge the battery before first use First Installation Charging the Battery 28 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTE...

Страница 29: ...beep 2 Pool unit and home unit are in handshaking process all LEDs blink green 3 Pool unit and home unit are connected analytics are up no presence in the pool pool activity indicator 1 blinks green slowly Downloading Coral Drowning Detection Application Download Coral Drowning Detection mobile application from Google Play Store or Apple App Store 2 1 First Installation Connecting the Home Unit 29...

Страница 30: ...n cellular communication When the carrier signal is not steady or weak you might not receive timely alerts and notifications Never rely solely on alerts on the mobile device Routine Operation Downloading Coral Drowning Detection Application 30 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 D...

Страница 31: ...n the pool unit 6 and on the home unit 2 z z Mobile app 3 When CORAL MANTA is operational it might identify one of the following scenarios z z Pool is Unoccupied z z Entrance to the Pool z z Normal Pool Use z z Drowning Suspicion z z Drowning Alert z z Drowning Critical Alert 1 3 5 2 6 1 Routine Operation Detection Scenarios 31 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE...

Страница 32: ...nk as long as there is someone in the pool NORMAL POOL USE z z Scenario description CORAL MANTA detects presence of at least one person in the pool No detection of drowning signs After the last person leaves the pool the status changes to Pool is Unoccupied If a person returns to the pool shortly after the pool was cleared CORAL MANTA skips the Entrance to the Pool state and does not send an alert...

Страница 33: ... Pool Use z z Indications pool activity indicator blinks red quickly buzzers sound a loud siren z z Alert Dismiss options the Dismiss button on the pool unit see Dismiss Button on page 12 and via the mobile app DROWNING CRITICAL ALERT z z Scenario description CORAL MANTA detects a person at risk of drowning for an additional 10 seconds z z Indications pool activity indicator blinks red quickly buz...

Страница 34: ...y store or the Apple App Store 2 Press Install 3 Allow the app to send notifications Otherwise alerts will not be received on the mobile device 4 Allow the app to access the camera in order to scan the QR code see QR code on page 36 Otherwise the CORAL ID will need to be entered manually 5 Follow the installation instructions Routine Operation Mobile Application Operation 34 MENU www INTRODUCTION ...

Страница 35: ...e first introductory screen after viewing the content 1 Routine Operation Mobile Application Operation 35 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 36: ... CORAL MANTA package or on the back of the home unit 1 Routine Operation Mobile Application Operation 36 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 37: ...working until all terms and disclaimers are acknowledged via the mobile app Routine Operation Mobile Application Operation 37 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 38: ...vel indicator 3 displays the pool unit battery level z z Refresh button 4 refreshes the app to display most current underwater image 4 3 1 2 Routine Operation Mobile Application Operation 38 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 39: ... Entrance to the Pool on page 32 z z Notification restrict 4 activating this option enables selecting a daily time frame during which no notifications are received 3 2 1 4 NOTE Notification restriction refers to non drowning notifications Drowning alarms can not be restricted and are received at all times Routine Operation Mobile Application Operation 39 MENU www INTRODUCTION FIRST INSTALLATION RO...

Страница 40: ... Mute button 2 to silence the buzzer sound 1 2 WARNING Do not dismiss or mute an alarm before verifying that there is no danger of drowning Never tap the False Alarm button 1 unless you are absolutely sure that there is no person in danger Routine Operation Mobile Application Operation 40 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MA...

Страница 41: ...g an alarm or an Entrance to the Pool alert the image that generated the alarm is displayed in the mobile application along with the following buttons z z Mute 3 tap to silence the alarm and not teach the system to ignore similar images in the future Use this option when there is a person in the marked square 1 but you are absolutely sure that there is no drowning risk e g someone is diving and ap...

Страница 42: ...gnore similar images in the future z z I M SURE DISMISS 2 tap if you are sure this image is a false alarm This action teaches CORAL MANTA to ignore any alarms generated from similar images in the future 2 1 Routine Operation Mobile Application Operation 42 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx...

Страница 43: ...pool CAUTION Keep the water in the pool as clear as possible according to best practice instructions Verify that the camera video footage is clear and that details on the far end of the pool can be viewed clearly Maintenance Pool Water Clarity 43 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 201...

Страница 44: ...27 3 Fully charge the battery using the pool unit charger see Charging the Battery on page 28 CAUTION Replace with a battery supplied by the manufacturer only Maintenance Battery Replacement 44 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 45: ...y that the pool unit is dry and clean 4 Cover the underwater tube end with the provided protective cover 5 Fold the underwater tube 6 Place the folded pool unit in the original package Maintenance Storing the System 45 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 46: ... card 2 into the slot 1 NOTE CORAL MANTA includes an integrated SIM card This procedure is applicable only for customers who purchased CORAL MANTA without an integrated SIM card 2 1 Maintenance SIM Replacement 46 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 47: ...ttery is partially charged Charge the battery see Charging the Battery on page 28 Battery level indicator 2 is steady red Battery charge is below critical level Charge the battery see Charging the Battery on page 28 Communication indicator 1 blinks blue quickly Communication Issue Check SIM card Internet package Verify communication to mobile device All LED indicators blink red Operation fault suc...

Страница 48: ...rs see Indicators on page 10 Pool activity indicator Communication indicator full medium low Battery level indicator full medium low Water visibility indicator yes no Alerts Siren low medium high Siren low medium high Controls Dismiss alarm IP level IP65 for out of water parts IP67 for underwater tube Operating temperature 10 40 deg 10 40 deg Specifications SIM Replacement 48 MENU www INTRODUCTION...

Страница 49: ...nitial Release 06 19 18 Rev B Teaching the System section added 07 09 18 Specifications Revision History 49 MENU www INTRODUCTION FIRST INSTALLATION ROUTINE OPERATION MAINTENANCE TROUBLESHOOTING SPECIFICATIONS CORAL MANTA User Guide Rev B Doc P N xxxx 09 07 2018 Do not distribute ...

Страница 50: ... of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language or computer language in any form or by any means electronic mechanical or otherwise without prior written permission of Coral Detection Systems 09 07 2018 Do not distribute ...

Отзывы: