background image

 

 

13 

9.11

 

NO CAP CHECK 

The  duplicator  has  a  built  in  capacity  check  function  which  will  check  the 

capacity  of  the  Master  drive  and  the  Target  drive(s)  during  Full  or  Brief  copy 

processes and determine whether the drives’  capacities are the same. 

Tap 

the  ‘ENT’  button to change this option’s setting. 

 

[  ] 

–  No  Capacity  Check  is  disabled  (default).  When  a  Full  or  Brief  copy 

process  is  executed  the  system  will  check  the  capacity  between  the  Master 

and Target hard drive(s) to determine whether the capacity is the same. If the 
capacity is different the copy process will be cancelled. 

 

٭

– No Capacity Check is enabled. When a Full or Brief copy process is 

executed  the  system  will  not  check  the  capacity  between  the  Master  and 
Target hard drive(s) and start the copy 

 

 

9.12

 

HPA CEHCK 

The Host Protected Area (HPA), sometimes referred to as the Hidden Protected 
Area, is a partition on the hard drive that is not normally visible to an operating 

system. 

Tap 

the  ‘ENT’  button to change this option’s setting. 

 

[  ] 

–  HPA  Check  is  disabled  (default).  The  system  will  not  check  for  HPA 

partitions. 

 

٭

 

– HPA Check is enabled. When HPA CHECK is enabled the duplicator 

will  support  Host  Protection  Areas.  When  you  duplicate  a  Master  Flash  that 

contains HPA, the system will detect the HPA partition, unlock it, copy the area 
and then re-lock the area once duplication is complete. 

Note: When you view Device Info (see section ) if the drive info displays 
an  ‘H’  in  the  upper  right  corner  then  the  device  contains  a  hidden  Host 

Protected Area. 

9.13

 

DCO CHECK 

The Device Configuration Overlay (DCO), sometimes referred to as the Hidden 

TARGET TOO SMALL ! 

ESC→NO, ENT→YES 

 

Содержание MFD-12

Страница 1: ...0 MFD12 FLASH COPIER User Manual V1 10 1107 2014 10 20 COPYSTAR BACKUP STORAGE CORPORATION jasmine ...

Страница 2: ... COPY 8 8 4 VERIFY 8 8 5 ERASE 9 8 6 DIAG 9 8 7 SETUP 9 9 SETUP MANUAL 10 9 1 SET TO DEFAULT 10 9 2 UPDATE FIRMWARE 10 9 3 FORMAT UPDATE DISK 10 9 4 SET COPY 10 9 5 SET COMPARE 11 9 6 SET QUICK ERASE 11 9 7 BRIEF IMMEDIATE 11 9 8 OPTIMIZE LOG TAB 12 9 9 SET DOD ERASE 12 9 9 1 000 ERS DOD CYCLES 12 9 10 SKIP READ ERROR 12 9 11 NO CAP CHECK 13 9 12 HPA CEHCK 13 9 13 DCO CHECK 13 9 14 CHECK SUM CHECK...

Страница 3: ... 23 SET WRITE PAT 16 9 24 DEVICE INFO 16 9 25 SYSTEM INFO 17 9 26 TOTAL COPY COUNT 17 9 27 BURN IN 17 9 28 DIAGNOSTIC SETUP 17 9 28 1 SET DIAG SMART 17 9 28 2 SET WRITE TEST 17 9 27 3 SET READ TEST 18 9 27 4 SET RANDOM READ 18 9 27 5 SET RANDOM WRT 18 9 27 6 SET DIAG PAT 18 9 29 LANGUAGE 18 9 29 1 ENGLISH 18 9 28 2 TRADITIONAL 19 ...

Страница 4: ...D 12 is one of the fastest cloning Flash systems available 2 FEATURES Up to 9GB min transfer rates MFD 12 Supports various Flash Memory including SATA DOM SATA Slim 7 pin or 22 pin CFAST IDE DOM IDE Slim M SATA M 2 NGFF Simultaneously clone up to 11 Flash drives Supports all standard Industry Flash drives Master Target drives can be different sizes brands and models Various Copy Compare Modes of O...

Страница 5: ...upports completed erase functions Support LBA 64 bit addressing and support more than 6TB capacity at least Log and Graphic UI Monitoring it supports to print store detail operation event log and also offers a friendly graphic user interface to monitor all copy channels status and results Standalone easy operation 3 SPECIFICATION Model MFD12 Copy Channel 11 Power 200W Weight 5kgs Dimension 45 8X26...

Страница 6: ... If any of the following items are missing please contact the COPYSTAR and replacement parts will be shipping to you ASAP MFD12 Flash Duplicator X1 AC Power Cord X1 User Manual X1 5 APPEARANCE 5 1 MFD12 FRONT VIEW ...

Страница 7: ...5 5 2 MFD12 BACK VIEW ...

Страница 8: ...6 6 PANEL 6 1 DUPLICATING DISK COPY T 11 135M 6 49 7492M TARGETS QUANTITY PROGRESS WORKING SPEED DATA SIZE COPY FUNCTION ...

Страница 9: ... COPY SET COMPARE SET QUICK ERASE BRIEF IMMEDIATE OPTIMIZE LOG TAB SET DOD ERASE NO CAP CHECK HPA CHECK DCO CHECK CHECK SUM CHECK SET SMART CHECK SMART WARNING BTN SOUND SHOW EXE TIME SHOW BINAEY BASE TRANS SIZE MAX UDMA MODE SETUP SET WRITE PAT DEVICE INFO SYSTEM INFO TOTAL COPY COUNT BURN IN SKIP READ ERROR CMD TIME OUT DIAGNOSTIC SETUP LANGUAGE ...

Страница 10: ...s FAT FAT32 NTFS If the Source is not formatted as a supported file system then the duplicator will automatically switch to FULL mode When duplicating in Resize mode Target drives should all be the same capacity 8 3 DISK COPY DISK Copy mode copied drives sector by sector from the Source to the Targets and support all major OS formats and unknown file system This DISK Copy mode will take more time ...

Страница 11: ... by writing zeros into each sector of the hard drive sector by sector 8 6 DIAG The Diagnostic feature allows you to run tests to verify the health of your target flash drives 8 7 SETUP To enter the SETUP menu from the Main menu press Up Down key to select SETUP and press ENT key ...

Страница 12: ...you want to format as a FAT32 drive to the duplicator s source port 2 In the SETUP menu navigate to FORMAT UPDATE DISK and then tap the ENT button To format the flash drive 3 You will receive a message asking you to confirm formatting the flash drive tap the ENT button or proceed or tap the ESC button to cancel Once the format has completed you will receive a message confirming that the format was...

Страница 13: ...m a Compare operation Compare enabled FULL BRIEF or RESIZE modes will perform a Compare operation Note To perform a Copy Compare operation set both the SET COPY and SET COMPARE options 9 6SET QUICK ERASE Simply erase all the data on the hard drive 9 7BRIEF IMMEDIATE BRIEF IMMEDIATE is used to change the analytical method in Brief mode The analyze source and copy work with the same time in Brief mo...

Страница 14: ...eration manual 9 10 SKIP READ ERROR The SKIP READ ERROR option allows you to enable or disable error skipping during FULL BRIEF and RESIZE modes Tap the ENT button to change this option Disabled default When an error is detected while reading from the Source the duplicator will cancel the current process Enabled When an error is detected while reading from the Source the duplicator will skip the b...

Страница 15: ...ter and Target hard drive s and start the copy 9 12 HPA CEHCK The Host Protected Area HPA sometimes referred to as the Hidden Protected Area is a partition on the hard drive that is not normally visible to an operating system Tap the ENT button to change this option s setting HPA Check is disabled default The system will not check for HPA partitions HPA Check is enabled When HPA CHECK is enabled t...

Страница 16: ...aster and Target s after copy process completed CHECK SUM CHECK is able to work with the FULL or BRIEF copy at the same time It will not take extra time to do it If you want to check the CRC of the Source Target s Hold ENT KEY one more second and navigate UP DOWN to check each hard drive 9 15 SET SMART CHECK S M A R T Self Monitoring Analysis and Reporting Technology is a monitoring system in hard...

Страница 17: ... Level 1 S M A R T data indicates a possible imminent writing error only the system will reject this drive and then copy another Level 2 Whatever S M A R T data indicates any error the system will reject this drives 9 17 BTN SOUND Disable Enable key bee sound 9 18 SHOW EXE TIME The SHOW EXE TIME option allows you to enable or disable whether the total execution time for an operation is displayed o...

Страница 18: ...mum transfer speed allowed Tap the ENT button to change this option The MAX UDMA M ODE can be set as 0 6 The MAX UDMA MODE is set to 6 by default 9 23 SET WRITE PAT SET WRITE PAT is used to define the data pattern that you want to write to all sectors of your Target drives during an Erase operation The Write Pattern can be set to E5 F6 00 FF C9 5A A5 AA RM Random Pattern The default value is 0x00 ...

Страница 19: ...system to perform a Copy Compare Verify Erase or Load function continuously to stress test for endurance reliability and stability 9 28 DIAGNOSTIC SETUP 9 28 1 SET DIAG SMART The S M A R T Self Monitoring Analysis and Reporting Technology is a monitoring for ATA hard drives to detect and report on various indicators of reliability Enable S M A R T feature Disable S M A R T feature 9 28 2 SET WRITE...

Страница 20: ...dom read data from sectors on the target flash drives for a period time 9 27 6 SET DIAG PAT SET DIAG PAT is used to define the data that you want to written to all sectors of your Target flash drives during an Write Test operation Tap the ENT button to change this option s setting Tap the ENT button to confirm your selection again Tap the ESC for escape 9 29 LANGUAGE 9 29 1 ENGLISH Push Up or Down...

Страница 21: ...19 9 28 2 TRADITIONAL Push Up or Down button to change English or Chinese and push ENT for confirmation Push ESC to escape ...

Отзывы: