Model

List #

Part Number

CLEI Code

FLC-706

1

150-1306-01

VACHEGJCAA

P

AIR

G

AIN 

T

ECHNOLOGIES

, I

NC

.

E

NGINEERING 

S

ERVICES 

T

ECHNICAL 

P

RACTICE

S

ECTION 

363-706-100-01

Revision History of this practice.

Revision 01—June 9, 1997

A) Initial Release.

Содержание 150-1306-01

Страница 1: ...RMINAL CHANNEL UNIT Model List Part Number CLEI Code FLC 706 1 150 1306 01 VACHEGJCAA PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE SECTION 363 706 100 01 Revision History of this...

Страница 2: ...leshooting 7 D TECHNICAL SUPPORT 7 9 Technical Support 7 E CERTIFICATION AND WARRANTY 8 10 Certification 8 11 Warranty 8 F ABBREVIATIONS 9 12 Abbreviations 9 USING THIS TECHNICAL PRACTICE Three types...

Страница 3: ...a PG Flex Central Office Terminal COT The FLC 706 accommodates four ISDN channels and provides ISDN Line Unit Network Termination LUNT at the COT The FLC 706 installs into a single slot of a PG Flex...

Страница 4: ...t Front Panel Table 1 FLC 706 Front Panel LEDs LED LED State Indicates ACTIVE 1 through 4 Solid green Fast flashing green Slow flashing green Channel is in sync Channel is attempting to sync Channel i...

Страница 5: ...ns Height 06 75 in 17 15 cm Depth 10 50 in 26 67 cm Width 01 00 in 02 54 cm Weight 00 80 lb 00 40 kg B FUNCTIONAL DESCRIPTION 4 Applications 4 1 ISDN is a networking standard that provides end to end...

Страница 6: ...lly Interim path performance monitoring collects the end to end error rate for the entire transport path 5 2 For system isolation and system tests the FLC 706 provides a hybrid transformer that isolat...

Страница 7: ...quence see Table 2 7 3 Provision the FLC 706 Provision the FLC 706 using a List 3 or higher CO Line Unit practice Access the ISDN Channel Setup menu and select the appropriate options 7 4 Connect cabl...

Страница 8: ...ou called is displayed when answered the number from which you called is displayed as the originating number 2 Hold up the B1 voice circuit then switch to the B2 data circuit 3 Originate an outgoing B...

Страница 9: ...Check loop or for network termination NT1 removal by customer Customer Reports No Dial Tone Off hook not extended to CO Check status LEDs Clear any indicated trouble Use PG Flex Line Unit maintenance...

Страница 10: ...pment in a residential area is likely to cause electrical interference in which case the user will be required to correct the interference at his own expense 11 Warranty 11 1 PairGain Technologies war...

Страница 11: ...COT Central Office Terminal DSL Digital Subscriber Line eoc Embedded Operations Channel ISDN Integrated Services Digital Network LUNT Line Unit Network Termination MLT Mechanized Loop Testing mp eoc M...