4.11: Control I/O
4.11.1: Non-Isolated Control - XEL/XPL/XML (J8)
Mating Connectors
Description
Manufacturer PN
Wire Size
26 Position, 0.1 x 0.09 High Density D-Sub Female, Solder Style
Connector
Norcomp 180-026-
203L001
24 - 30 AWG
Back shell
Norcomp 979-015-
020R121
Solder style connector included in Connector Kits XEL-CK, XML-CK, and XPL-CK.
Pin connections for the bulkhead connector on the drive are shown here:
Pin Description
Pin Signal
Function
1
Frame Ground
Cable shield connection.
2
Ref + (AIN1 +)
Analog command positive input
—single analog.
3
Ref
– (AIN1 -)
Analog command negative input--single analog.
4
IN1
Enable
5
IN2
Programmable input.
6
IN3
Mode-Dependent Dedicated Inputs (p. 111)
.
7
IN4
8
IN5
9
AOUT
Programmable, 12-bit, ±5 Vdc.
10
IN6
Mode-Dependent Dedicated Inputs (p. 111)
.
11
AIN2 +
Analog input 2 positive input.
12
AIN2 -
Analog input 2 negative input.
13
Multi-mode port /S2
Mode-Dependent Dedicated Inputs (p. 111)
.
14
Multi-mode port S2
15
Signal Ground
Signal ground reference for inputs and outputs.
16
OUT1
Programmable outputs.
17
OUT2
18
OUT3 (HS)
19
Signal Ground
Signal ground for +5Vdc, inputs and outputs.
Continued…
9
1
18
26
19
10
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...