Accelnet & Stepnet Plus Panels User Guide
16-01339 Rev 07
MACRO:
BML
M
ATING
C
ONNECTOR
Dual SC sockets accept standard optical fiber. The IN port connects to a master, or to the OUT port of a device
that is ‘upstream’, between the Accelnet and the master. The OUT port connects to ‘downstream’ nodes. If
Accelnet is the last node on a network, only the IN port is used. No terminator is required on the OUT port..
5.11 C
ONTROL
I/O
BEL,
BPL,
BML,TEL
S
IGNAL
C
ONNECTOR
Description
Manufacturer PN
Connector, High-density Dsub DB-44M, 44 position, male,
solder-cup, with #4-40 locking screws
Norcomp: 180-044-103L001
Backshell, Dsub, RoHS, metallize
Norcomp: 979-025-020R121
J1
P
IN
D
ESCRIPTIONS
Pin
Signal
Pin
Signal
Pin
Signal
1
Frame Ground
16
Signal Gnd
31
Signal Gnd
2
Ain(-)
17
+5Vdc Out1
32
+5Vdc Out1
3
Ain(+)
18
MultiEnc /S
33
MultiEnc S
4
N/C
19
MultiEnc /X
34
MultiEnc X
5
N/C
20
MultiEnc /B
35
MultiEnc B
6
Signal Gnd
21
MultiEnc /A
36
MultiEnc A
7
[IN1]
22
Signal Gnd
37
Signal Gnd
8
[IN2]
23
N/C
38
N/C
9
[IN3] Diff1(+)
24
N/C
39
N/C
10
[IN4] Diff1(-)
25
[OUT3-]
40
[OUT3+]
11
[IN5] Diff2(+)
26
[OUT2-]
41
[OUT2+]
12
[IN6] Diff2(-)
27
[OUT1-]
42
[OUT1+]
13
[IN7]
28
[INCOM]
43
N/C
14
[IN8]
29
N/C
44
Signal Gnd
15
[IN9]
30
[IN10]