Accelnet & Stepnet Plus Panels User Guide
16-01339 Rev 07
4.15 S
TATUS
I
NDICATORS
D
RIVE
S
TATUS
I
NDICATOR
BEL, BPL, TEL
BE2, BP2, TE2, TP2
BML
AMP LED
A bi-color LED gives the state of the BEL drive. Colors do not alternate, and can be solid ON or blinking. When
multiple conditions occur, only the top-most condition will be displayed.
When that condition has been cleared the next one below will shown.
Red/Blinking
=
Latching fault. Operation will not resume until drive is Reset.
Red/Solid
=
Transient fault condition. Drive will resume operation when
the condition causing the fault is removed.
Green/Double-Blinking
=
STO circuit active, drive outputs are Safe-Torque-Off
Green/Slow-Blinking
=
Drive OK but NOT-enabled. Will run when enabled.
Green/Fast-Blinking
=
Positive or Negative limit switch active.
Drive will only move in direction not inhibited by limit switch.
Green/Solid
=
Drive OK and enabled.
Will run in response to reference inputs or EtherCAT commands.
Off
=
No HV or HVAUX power to drive
Latching Faults
Defaults
Optional (programmable)
• Short circuit (Internal or external)
• Over-voltage
• Drive over-temperature
• Under-voltage
• Motor over-temperature
• Motor Phasing Error
• Feedback Error
• Command Input Fault
• Following Error
• Motor Wiring Disconnected
• Over-current (Latched, I
2
T)