4 S
PECIFICATIONS
4.1 DC
I
NPUT
P
OWER
+HV is required for operation of the drives. AuxHV is optional and powers the communications, feedback, and
I/O functions but not the PWM outputs. AuxHV is recommended for drives operating on a control network
because it enables the network master to maintain communication with the drives when the +HV has been
removed, most commonly for safety or EMO (Emergency Off) conditions.
S
INGLE
-A
XIS
S
ERVO
M
ODELS
:
BEL,
BPL,
BML
Model
BEL-090-06
BPL-090-06
BML-090-06
BEL-090-14
BPL-090-14
BML-090-14
BEL-090-30
BPL-090-30
BML-090-30
Unit
DC +HV Voltage***
+14 to +90 (
transformer-isolated from AC mains
)
Vdc
Peak +HV Current
6
14
30
Adc
Peak Current Time
1
Sec
ContHV Current
3
7
15
Adc
AuxHV Supply Voltage***
+14 to +90 (
transformer-isolated from AC mains
)
Vdc
AuxHV Supply Current
500 mA maximum
Adc**
*The HV current is dependent on the input voltage and motor load and operating conditions.
The MHV currents shown above occur when the drive is operating from the maximum input
voltage and is producing the rated continuous output current at the maximum output voltage.
** AuxHV supply current depends on the number of encoders connected to the drive. The maximum
current draw given assumes that the e5V output is loaded to 500mA.
*** Supply Short Circuit Current Rating (SCCR) must be 5k Arms maximum
D
UAL
-A
XIS
S
ERVO
M
ODELS
:
BE2,
BP2
Model
BE2-090-06
BP2-090-06
BE2-090-14
BP2-090-14
BE2-090-20
BP2-090-20
Unit
DC +HV Voltage***
+14 to +90 (
transformer-isolated from AC mains
)
Vdc
Peak +HV Current
12
28
40
Adc
Peak Current Time
1
Sec
ContHV Current
6
14
20
Adc
AuxHV Supply Voltage***
+14 to +90 (
transformer-isolated from AC mains
)
Vdc
AuxHV Supply Current
500 mA maximum
Adc**
*The HV current is dependent on the input voltage and motor load and operating conditions.
The MHV currents shown above occur when the drive is operating from the maximum input
voltage and is producing the rated continuous output current at the maximum output voltage.
** AuxHV supply current depends on the number of encoders connected to the drive. The maximum
current draw given assumes that the two e5V outputs are each loaded to 500mA.
*** Supply Short Circuit Current Rating (SCCR) must be 5k Arms maximum