background image

 

 

INSTALLATION INSTRUCTION -- ‘’CL’’ HEATING CABLE 

READ CAREFULLY BEFORE BEGINNING INSTALLATION 

      
1. 

Clean the room.

 

2. 

Make sure that the floor surface is free of any irregularities

 

3. 

 The heating cable length must not be altered, cutted or shortened

However the cold lead 

can be cut to desired length.  The identification label must be reattached for future identification.

 

4. 

All Copal’s Heating Cables are fabricated of high quality materials and have been tested prior to 

shipping.   Refer to the identification label at the end of the cold lead concerning the voltage and 

the cable type. It is recommended making a reading with an ohmmeter.  The ohmmeter reading 

should match the resistance printed on the identification label.

 

 
Installation 
The  installation  needs  two  (2)  concrete  casting.      Install  prepunched  strapping  as  per  Drawing  #1.  
Provide enough prepunched strapping to ensure that the cables remain in place during the casting.  It 
is recommended to cover the cables with 1½ ‘’ to 2’’ of concrete.  

 
The cables must never cross an expansion joint. 

 

        

                 Drawing #1      

 

    
 

6.   Connections

 

Use  cable  at  voltage  specified  on  the  Identification  label.  Copal’s  heating  cable  is  an  electrical 
appliance  and  should  be  installed  by  a  professional  electrician.    Its  installation  is  under  strict 
standards issued by electrical and building codes (national and/or local)  

 

The heating cable must be control by an electronic thermostat which sensor install in a ½’’ diameter 
flexible PVC conduct at the floor level. The Electrical Code requires a Ground Fault Circuit Interrupter 
(GFCI) be used on the branch supply circuit for shock safety and fire protection. 

                                                                      

 

                                                                                                              

 

 

Отзывы: