background image

P83611 J 

Sheet 1 of 4

 

 

273 Branchport Avenue 
Long Branch, NJ  07740  

 

 

 

 

 

 

 

 

 

   

Thank you for using our products.

 

(800)  631-2148 
www.coopernotification.com   

 

 

 

 

 

 

 

 INSTALLATION INSTRUCTIONS 

AMT MULTITONE APPLIANCES 

AMT-12/24-NYC 

 

Use this product according to this instruction manual.  Please keep this instruction manual for future reference. 

 

GENERAL: 

AMT Multitone Appliances are UL Listed for Fire Protective Service, General Signaling Service and UL Standard 464 for Audible Signal Appliances.  They are 
listed for both indoor and outdoor use with the backboxes specified in these instructions.  (See Mounting Options A,B,C,D,E,F,G).  Cooper Notification's AMT 
Appliances  are  unique  multitone  alarm  appliances  with  separate  input  terminals  for  each  sound.   They are the ideal choice for Halon Protection Systems and 
emergency  signaling  systems where  distinctive  multiple alarm conditions are required.  Eight groups of three self-prioritized sound outputs are provided with 
separate electrically isolated input terminals for each sound (see Table 2 and 4 for sound selections).  Sound output can be field set to provide either HIGH (HI) 
dBA or STANDARD (STD) dBA sound output level.  AMT Multitone Appliances can be field set for either 12VDC or 24VDC operation  and are designed for 
use  with  either  filtered  or  unfiltered  (full-wave-rectified)  input  voltage.   All inputs are polarized for compatibility with standard reverse supervision of circuit 
wiring by Fire Alarm Control Panel (FACP). 

NOTE:

  All 

CAUTIONS

 and 

WARNINGS

 are identified by the symbol 

.  All warnings are printed in bold capital letters. 

 

WARNING:    PLEASE  READ  THESE  INSTRUCTIONS  CAREFULLY  BEFORE  USING  THIS  PRODUCT.    FAILURE  TO  COMPLY  WITH 

ANY  OF  THE  FOLLOWING  INSTRUCTIONS,  CAUTIONS  AND  WARNINGS  COULD  RESULT  IN  IMPROPER  APPLICATION, 
INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY 
DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 

 

WARNING:  THE AMT MULTITONE APPLIANCES MUST BE FIELD SET TO THE DESIRED INPUT VOLTAGE, dBA SOUND OUTPUT 

LEVEL  AND  ALARM  TONE  BEFORE  THEY  ARE  INSTALLED.    THIS  IS  DONE  BY  PROPERLY  INSERTING  A  JUMPER  PLUG  AND 
ADJUSTING  A  FOUR  POSITION  SWITCH IN  ACCORDANCE WITH THESE INSTRUCTIONS.  INCORRECT SETTINGS WILL RESULT IN 
IMPROPER  PERFORMANCE  AND  MAY  DAMAGE  THE  PRODUCT,  WHICH  COULD  RESULT  IN  PROPERTY  DAMAGE  AND  SERIOUS 
INJURY OR DEATH TO YOU AND/OR OTHERS. 
 
SPECIFICATIONS:   

Table 1:  dBA Ratings for AMT Multitone Appliance 

Tone 

Rated Reverberant dBA At 10 Feet Per UL 464 

At Minimum 

Input Voltage 

At Nominal 

Input Voltage 

HI 

STD 

HI 

STD 

Bell 

82 

75 

85 

79 

Code 3 Tone 

85 

79 

88 

82 

Vibrating Chimes 

79 

73 

82 

75 

 

Table 2:  Current Ratings for AMT Multitone Audible Appliances 

 

Tone 

 

Tone 

Description 

Maximum RMS Current 

(AMPS) 

24VDC 

24VRMS 

12VDC 

12VRMS 

HI 

STD 

HI 

STD 

HI 

STD 

HI 

STD 

Bell 

1560 Hz Modulated (0.07 Sec. ON/Repeat) 

0.057 

0.026 

0.040 

0.028 

0.117 

0.031 

0.150 

0.057 

Code 3 Tone 

500 Hz (ANSI S3.41 Temporal Pattern) 

0.060 

0.030 

0.051 

0.031 

0.168 

0.052 

0.216 

0.100 

Vibrating Chime 

700Hz (1.0 Sec. Decay/Repeat) 

0.041 

0.020 

0.044 

0.029 

0.090 

0.028 

0.108 

0.042 

 

WARNING:    CHECK  THE  MINIMUM  AND  MAXIMUM  OUTPUT  OF  THE  POWER  SUPPLY  AND  STANDBY  BATTERY  AND 

SUBSTRACT  THE  VOLTAGE  DROP  FROM  THE  CIRCUIT  WIRING  RESISTANCE  TO  DETERMINE  THE  APPLIED  VOLTAGE  TO  THE 
SIGNALING APPLIANCE. 

 

WARNING:    FOR  UL  APPLIANCES  THESE  APPLIANCES  WERE  TESTED  TO THE  OPERATING VOLTAGE  LIMITS  OF  16-33  VOLTS 

FOR  24V  APPLICATIONS  AND  8.0-17.5  VOLTS  FOR  12V  APPLICATIONS  USING  FILTERED  (DC)  OR  UNFILTERED  FULL-WAVE-
RECTIFIED (FWR).  DO NOT APPLY 80% AND 110% OF THESE VOLTAGE VALUES FOR SYSTEM OEPRATION. 

 

WARNING:    MAKE  SURE  THAT  THE  TOTAL  RMS  CURRENT  REQUIRED  BY  ALL  APPLIANCES  THAT  ARE  CONNECTED  TO  THE 

SYSTEM’S PRIMARY AND SECONDARY POWER SOURCES, NAC CIRCUITS, OR COOPER NOTIFICATIONS POWER SUPPLIES DO NOT 
EXCEED  THE  POWER  SOURCES’  RATED  CAPACITY  OR  THE  CURRENT  RATINGS  OF  ANY  FUSES  ON  THE  CIRCUITS  TO  WHICH 
THESE  APPLIANCES  ARE  WIRED.    OVERLOADING  POWER  SOURCES  OR  EXCEEDING FUSE  RATINGS  COULD  RESULT  IN  LOSS  OF 
POWER  AND  FAILURE  TO  ALERT  OCCUPANTS  DURING  AN  EMERGENCY,  WHICH  COULD  RESULT  IN  PROPERTY  DAMAGE  AND 
SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 

 

Copyright 2015 Cooper Wheelock Inc., dba Cooper Notification.  All rights reserved. 

Отзывы: