Cooper Lighting Power Failure Emergecny Light ENC Скачать руководство пользователя страница 1

INVUE

TM

1120

COOPER LIGHTING

D I M E N S I O N S

W

ALL MOUNT

• One piece die-cast

aluminum construction.
Accommodates either 
up or down mounting
configurations with no
modifications

• One piece die-cast

aluminum faceplate
utilizes a continuous
silicone gasket to seal
securely to housing

• Side hinged faceplate

swings open via release
of one (1) flush mount
die-cast aluminum latch
on housing side panel

• Choice of ten (10) high

efficiency optical systems 

• Ballast and related

electrical componentry
are heat sunk to the
housing

• Optional die-cast

aluminum adapter box to
allow for surface conduit
wiring, quartz lamp
options, and emergency
battery pack capability

• Approximate net weight:

13 lbs. (6 kgs.)

D E S C R I P T I O N

ENTRI Series’ family of modular
faceplate designs provide a
tasteful architectural statement
equally suitable for indoor and
outdoor environments. Available
luminous faceplate window adds
a signature look, while affording
custom color capability.

ENC

ENTRI  ROUND
CLEAN

2 6 - 2 5 0 W

M e t a l   H a l i d e

W h i t e S O N   H i g h   P r e s s u r e

S o d i u m

C o m p a c t   F l u o r e s c e n t

Q u a r t z   H a l o g e n

A R C H I T E C T U R A L   W A L L

L U M I N A I R E

15 25/32" [400 mm]

7 3/4"

[196 mm]

8 1/8" [206 mm]

IP66 Rated

U.L. 1598

Full Cutoff

FCO

CSA Listed

 40°C Ambient

 ISO 9001

Certifications

NOTE: 250W Quartz requires thru-way mounting box. 150W requires 
          magnetic ballast.

In downlight only configurations with no
faceplate window.

Optional Luminous Faceplate Insert

14

LG

=Luminous Glass Insert

LGO

=Luminous Glass Insert 

with Warm Orange Gel

LGR

=Luminous Glass Insert 

with Red Gel 

LGB

=Luminous Glass Insert 

with Bright Blue Gel

LGG

=Luminous Glass Insert 

with Deep Green Gel

Options

14

F

=Single Fuse (120, 277 or 347V) 

Specify Voltage

FF

=Double Fuse (208, 240 or 480V) 

Specify Voltage

DSAB

=Dual Fluorescent Switching 

Control Adapter Box 

15

QAB

=Quartz Restrike Adapter Box

EMAB

=Quartz Restrike with Delay Adapter Box

(Also Strikes at Cold Start)

EM/SCAB

=Quartz Emergency Separate Circuit

Adapter Box

CF/EMAB

=Emergency Battery Backup Adapter Box

(Specify 120 or 277V)

16

PC

=Button Type Photocontrol 

(specify voltage)

WG

=Wire Guard

17

FRM

=Frosted Main Flat Glass

FRS

=Frosted Secondary Flat Glass

18

L

=Lamp Included 

(Standard for all Halogen lamps) 

Accessories

19

VA2001-XX

=Thru-way Box

VA2002-XX

=Wire Guard Kit

NOTES

:

1

All MH lamps are T6 envelope with G12 lamp base. All HPS lamps are T6 envelope with GX12 lamp base. 

2

All 26/32/42/57W CF lamps feature a 4-pin lamp

base. Available in CFM and CFG distributions only. 

3

Dual compact fluorescent lamps. 

4

Nominal M.O.L lamp length of 57W CFL not to exceed 7". 

5

All Halogen

lamps are T4 envelope with mini-can base, 120V lamp. 

6

WhiteSON HPS lamp available in 100W only. Requires electronic ballast. 120/277V only. Includes use of

VA2001 accessory Thru-way Box. 

7

Compact Fluorescent ballasts contain internal fusing. No supplemental fusing is necessary. CF ballasts are 120 through 277V.

Specify with UNV voltage designation. 

8

Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and

ordering information. 

9

Dual-tap is 120/277V wired 277V. 

10

Multi-tap is 120/208/240/277V wired 277V. 

11

Triple-tap is 120/277/347V wired 347V. 

12

120 through

277V only. Electronic ballasts contain internal fusing, no supplemental fusing is necessary. Electronic ballast available with all CF lamps, and 39/70/100W MH

lamps. Available with 150W MH lamp. Includes VA2001 accessory Thru-way Box. Not available with QAB or EMAB options. 

13

Custom and RAL color matching

available upon request. Consult your INVUE Lighting Systems Representative for further information. 

14

Add as suffix in the order shown. 

15

Dual switching

requires dual 26, 32 or 42W Compact Fluorescent lamps. Allows independent switching control of each lamp through use of two (2) electronic ballasts. Allows

50% power reduction when dual ballasts are independently wired and controlled. 

16

CF lamps only. Battery backup operates 90 minutes at minimum 32°F (0°C),

42W maximum. 

17

For use in down lighting applications only. 

18

Frosted secondary lens provided standard on 3SG, FTG, and CFG distributions. 

19

Order

separately, replace XX with color suffix. 

20

Specifications and dimensions subject to change without notice.

O R D E R I N G   I N F O R M AT I O N

S A M P L E   N U M B E R :  

E N C - 1 5 0 - M H - 1 2 0 - E B - 3 S - B K - L G - L

Product Family 
ENC

=ENTRI

Round
Clean

Lamp
Wattage
HID

1

39

=39W

70

=70W

100

=100W

150

=150W

Compact
Fluorescent

2

26

=26W

32

=32W

42

=42W

52

=52W

3

57

=57W

4

64

=64W

3

84

=84W

3

Halogen

5

100

=100W

150

=150W

250

=250W

Lamp Type
MH

=Metal Halide

WS

=White SON

High
Pressure
Sodium

6

CF

=Compact

Fluorescent

7

HL

=Quartz

Halogen

Optical System
Downlight or 
Uplight (HID or
Halogen)
3S

=Type III

FT

=Forward

Throw

FX

=Wall Grazing 

Optic

TS

=Tight Spot

Downlight and Uplight (HID and Halogen)
3SG

=Type III, 90% Main/10% Secondary 

Glow

3SP

=Type III with Pencil Secondary

FTG

=Forward Throw, 90% Main/

10% Secondary Glow

FTP

=Forward Throw with Pencil Secondary

FXF

=Wall Grazing Optic, 50% up/50% Down

TSF

=Tight Spot, 50% up/50% Down

Compact Fluorescent
CFG

=90% Main + 10% Secondary Glow

CFM

=100% Main, Up or Downlighting

Colors

(add as 

suffix/must specify)

13

BK

=Black

AP

=Grey

BZ

=Bronze

WH

=White

DP

=Dark Platinum

GM

=Graphite Metallic

Options &
Accessories

(See Below)

Voltage

8

120

=120V

208

=208V

240

=240V

277

=277V

347

=347V

480

=480V

DT

=Dual-Tap

Wired 277V 

9

MT

=Multi-Tap 

Wired 277V

10

TT

=Triple-Tap 

Wired 347V

11

UNV

=120-277V

Universal
Electronic
Ballast

Ballast
MB

=Magnetic 

EB

=Electronic

Ballast

12

X

=None 

(for Halogen
Lamp)

 ENC

Metal Halide

 

39, 70, 100, 150W

White Son HPS

 100W

Compact Fluorescent

 

26, 32, 42, 57W

Dual Compact Fluorescent

 

(2) 26, (2) 32, (2) 42W

Quartz Halogen

 100, 

150, 

250W

WATTAGE TABLE

Отзывы: