Cooper Lighting PD6-V142 Скачать руководство пользователя страница 1

D E S C R I P T I O N

S P E C I F I C A T I O N   F E A T U R E S  

6

OPEN DOWNLIGHT

OPEN WALL WASH

C A T A L O G

#

:

T Y P E :

PD6-V142

4 2 W   T T T  

C o m p a c t   F l u o r e s c e n t

6 "

O P E N   D O W N L I G H T

6 "

O P E N   W A L L   W A S H  

COOPER LIGHTING

ADV995023

26 3/8"

[671mm]

10 5/8"

[268mm]

12 7/8"

[327mm]

Top View

6 1/4"

[158mm]

5 3/4"

[146mm]

7"

[176mm]

8 7/8"

[225mm]

C

E

D

G

F

A

B

V142E

=(1) 42, 32 or 26W Triple tube

lamp, multi voltage ballast.

6VC

=6" Vertical Clear

6VWC

=6" Vertical Open Wall Wash, Clear

6VBB

=6" Vertical Black Baffle

6VWB

=6" Vertical White Baffle

O R D E R I N G   I N F O R M A T I O N

S A M P L E   N U M B E R :   P D 6 - V 1 4 2 E - 6 V C

O r d e r   f r a m e ,   s o c k e t   a d a p t e r   a n d   r e f l e c t o r   s e p a r a t e l y   f o r   a   c o m p l e t e   u n i t .

PD6

PD6

R e f l e c t o r

V 14 2 E

S o c k e t   A d a p t e r

F r a m e

The Performance Downlight
System (PDS) combines visually
comfortable optics, energy
efficiency and modularity with
availability. Three key elements—
reflector, socket adapter and
frame—combine to form a feature-
packed luminaire. 

PDS reflectors boast equal 55°
cutoff to lamp and lamp image.
Low-iridescent clear reflector with
white-painted self flange is
standard. 

PDS socket adapters provide
modular flexibility and assure
proper lamp orientation and lamp
quantity to be used with each
reflector. Lamp positions lock into
place ensuring photometric
performance. Electronic ballasts are
standard. 

PDS frames are dedicated to each
aperture size and are used for
compact fluorescent, metal halide
and incandescent sources. No Fuss
Bar Hangers™ speed installation of
frames, minimizing labor costs on
the job site.

A

...

Reflector

One-piece optical reflector
minimizes internal losses and light
leaks. 5/8" overlapping flange
provides gap-free aperture.
Standard finish is low-iridescent
clear with white painted self-flange.
Torsion spring mounting pulls
flange tight to ceiling. 
Wall wash reflector utilizes
injection-molded GRUVI,
mechanically fastened to the
reflector.

B

...

Baffles 

One-piece black or white baffle.
Upper specular reflector maximizes
light output. Self-flange of each is
painted white. 

C

...

Socket Cap

One-piece metal cap. Positive
connection between cap and
reflector is provided by a twist-and-
lock mechanism. Multiple slots
allow for precise lamp positions.

D

...

Socket and Socket Adapter 

4-pin G24q base with stainless
steel spring for positive retention
of 42, 32, and 26W triples. Guide
post inserts rejects two-pin bases
to ensure proper lamping. Multi-
voltage ballast accommodates
120V thru 277V.

E

...

Frame 

Galvanized steel frame with 
1/2" plaster lip is standard.
Accommodates ceilings up 
to 2" (50mm) thick.

F

...

No Fuss Bar Hanger

Bar hanger locks to T-bar with a
screwdriver or pliers. Centering
mechanism allows consistent
centering of fixtures. 2 1/2"
vertical adjustment. Can be 
used with 1/2" EMT

G

...

Junction Box

Galvanized with (6) 1/2" and 
(2) 3/4" KOs. 

Insulation Detector

Thermal protection deactivates unit
if improper lamp type or wattage is
used, or if insulation is placed too
close to the fixture.

Labels

CUL Iisted,  damp location, IBEW
union made. 

E n e r g y   D a t a

V 1 4 2 E

Lamp

System

Open

Voltage wattage : wattage

circuit 

Input 120V, 42W :  47.0W, 0.39A 

120V, 32W :  34.5W, 0.30A
120V, 26W :  26.0W, 0.22A
277V, 42W :  47.0W, 0.13A
277V, 32W :  34.5W, 0.13A
277V, 26W :  26.0W, 0.09A

Power Factor: >.98
THD: <10%: 
Sound Rating: A
Min Starting Temp.: -0°C (20°F)

10/11/2007