Cooper Lighting Paralux III EP3GAX Series Скачать руководство пользователя страница 1

P

ARALUX III

393

COOPER LIGHTING

• Equipped with energy

saving ballasts/complies
with federal energy
efficiency standards

• Computer designed,

precision cell louver
technology

• Balanced low brightness

illumination reduces glare,
increased VCP’s

• Precision tolerance

construction/fixture
housing to louver

• Four auxiliary fixture end

suspension points 
provided

• Interlocking tabs and

screws secure end plates

DLS

Dimming Ballasts are

available

• End plate grid-lock feature 

(1)

• Efficient air handling options

• Floating louver/black reveal

• For information on flanged

fixture, including ceiling
opening size, see Technical
Section.

• UL/CUL Listed. Suitable for

damp locations.

EP3GAX

SERIES

1 '   x   4 '   P a r a b o l i c  

1   o r   2   L a m p s

S y m m e t r i c   W a l l   W a s h

A s y m m e t r i c   W a l l   W a s h

L i b r a r y   S t a c k

O v e r   A n d   U n d e r

P a r a b o l i c   L o u v e r

PA R A L U X   I I I   R E C E S S E D

S T AT I C   O R   A I R   S U P P LY

T R O F F E R

D E S C R I P T I O N

The Precision Parabolic 3" high performance
louver incorporates a precision designed
optical assembly that offers the specifier a
controlled, high performance light source with
application versatility.

The Symmetric High

throw wall wash

luminaire produces uniform vertical wall
illumination on both sides of luminaire from
the ceiling line to the floor. The double wall
wash distribution eliminates the “Cave Effect”.
The symmetric high throw is the ideal
luminaire for wall washing applications.

The Asymmetric High

throw luminaire

produces uniform vertical wall illumination on
one side of the luminaire from the ceiling line
to the floor. The wall wash distribution
eliminates the “Cave Effect”.  The asymmetric
high throw is the ideal luminaire for wall
washing applications.

The Library/Vertical Stack

luminaire produces

uniform illumination levels on the entire face
of the stack, top to bottom. The vertical
illumination optical assembly precisely directs
light between library stacks. The library stack
is the ideal luminaire for libraries and other
narrow aisle stack applications.

The Library Stack, Over and Under,

two lamp

configuration produces uniform illumination
levels on the entire face of the stack, top to
bottom. The vertical illumination optical
assembly precisely directs  light between
library stacks. The library stack is the ideal
luminaire for libraries and other narrow aisle
stack applications.

HR

Heat

Removal

(1)

Number
of Lamps
1

=1 Lamp

2

=2 Lamp

Wattage (Length)
32

=32W T8 (48")

EP

=Paralux Louver

Voltage

(4)

120V

=120 Volt

277V

=277 Volt

347V

=347 Volt

UNV

=Universal

Voltage 120-277 

(5)

Louver Color 
S

=Silver

3

=3" Louver Depth

Trim Type
G

=Grid/Lay-in – Standard

G

or

T

=Concealed T

G

or

T

=Slot Grid

(2)

F

=Flange Trim

MZ

=Modular Trim

Convertible Fixture 

(3)

Standard G

(Grid) Type-Fixtures can be field
converted to T-option or vice-versa.
Fixture also adaptable with flanged or
modular trims.

AX

=Air Supply Floating Louver

X

=Blank Side/Floating Louver -

Non-Air Supply (Omit A)

AVX

=Air Supply Floating Louver

with Directional Air Vane (Add V)

Cell Configuration
18

=1 Row of 8, 8 Cell

Louver Finish
MI

=Specular/Mirrored (Low Iridescent)

Distribution
SYM

=Symmetric High Throw Wall Wash

ASY

=Asymmetric High Throw Wall Wash

VS

=Vertical Stack/Narrow Distribution

Over and
Under

Vertically
Oriented
Lamps

O R D E R I N G   I N F O R M AT I O N

S A M P L E   N U M B E R :   E P 3 G A X - 1 3 2 - S 1 8 M I S Y M - 1 2 0 V - E B 8 1 - U

Options
GL

=Single Element Fuse

GM

=Double Element Fuse

WTR

=White Reveal

Lamps

- for lamps installed, see lamp options table

Flex

- for flex installed, see flex ordering table

Emergency

- for EM installed, see EM options table

Housing Louver 

Cell

Number

Size

Configuration*

of Cells

1' x 4'

18

8

*Example: 18= 1 rows of 8 (8 cells)

P R O D U C T   I N F O R M AT I O N   F O R   PA R A L U X   I I I

Ballast Type

(4)

EB8

= T8 Electronic Instant Start. 

Total Harmonic  Distortion < 10%

EB8 /PLUS

= T8 Electronic Instant Start. 

High Ballast Factor >1.13. Total 
Harmonic  Distortion < 20%

ER8

= T8 Electronic Program Rapid Start. 

Total Harmonic Distortion < 10%

DLS

=Digital Lighting System Dimming

(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)

No. of Ballast
1, 2 or 3

No. of 
Ballast
1, 2 or 3

No. of Ballast
1, 2 or 3

Options

(See Options
Section)

Packaging
U

=Unit Pack

PAL

=Job Pack,

out of carton

PALC

=Job Pack,

in carton

NOTES:

(1)

Integral end plate grid lock feature not available in heat removal. 

(2)

An EQ Grid Clip is recommended for all 9/16" ceiling systems. 

(3)

Convertibility applies to

housing only, appropriate shielding media assemblies must be utilized. 

(4)

Products also available in non-US voltages and frequencies for international markets. 

(5)

Not available when specifying emergencies, voltage must be specific.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.

LOUVER

A

B

Symmetric,

11-3/4" (298mm)

6-5/8" (168mm)

Asymmetric, Library

11-3/4" (298mm)

6-5/8" (168mm)

Over and Under

11-3/4" (298mm)

8-1/4" (210mm)

Symmetric Wall Wash (SYM)

Asymmetric Wall Wash (ASY)

Library Stack (VS)

Over And Under (VS)

D I M E N S I O N S