SPECIFICATION FEATURES

07/20/2007 9:40:15 AM

Consult your representative for additional options and finishes.

Specifications and Dimensions subject to change without notice.

ADN070872

ORDERING INFORMATION

DESCRIPTION

The Nimbus II Wall series offers simple design and flexibility without 
sacrificing performance. Multiple lamp configurations in T8 and T5 high 
output fluorescent provide maximum flexibility for the architectural 
environment. Nimbus II creates a comfortable and uniformly balanced 
environment. All of these elements combined make the Neoray Nimbus II an 
excellent selection for private offices, open office areas, VDT workspaces, 
classrooms and corridors.

A ... Construction

Housing is one-piece, die-formed, 
cold rolled steel, forming a 7" x 
2-1/2" architectural profile. 
Perforated sections are 33% open 
with .1563" staggered hole pattern 
and opal diffuser. Standard 4'-0" 
and 8'-0" luminaire lengths 
combine for continuous runs.

B ... End Caps

Standard end caps are precision 
die-cast aluminum mechanically 
attached without exposed 
fasteners.

C ... Reflectors

Reflector is die-formed, semi-
specular anodized aluminum.

D ... Electrical

Luminaires are prewired with quick 
wire connectors and use UL list 
Class P, 265ma T8 electronic 
ballasts. Power factor of 95% with 
less than 20% THD. Fixtures and 
electrical components certified to 
UL and CUL standards.

E ... Finish

Luminaire housings are standard 
white using electrostatically 
applied acrylic powder coat paint.

Mounting

Fixture mounts directly to existing 
structure over a 2" x 4" standard 
electrical box mounted horizontally 
in the wall. Refer to installation 
section for details.

Nimbus II

701-IW

2T8

WALL-MOUNT

SEMI-INDIRECT

Light Distribution

Indirect - 95.7%

Direct - 4.3%

7" [177mm]

2-1/2"

[63mm]

A

C

E

D

END CAP 

B

5" [127mm]

2-1/2"

[64mm]

7-1/8" [181mm]

S TA N D A R D   L U M I N A I R E   L E N G T H S

M O D U L A R   R O W   C O N F I G U R AT I O N

• Standard length sections join easily to create rows. 

• Sections align with T-grid. 

• All sections prewired for through-wiring with quick connectors.

S A M P L E   N U M B E R :   7 0 1 I W - S P - 2 T 8 - 1 C - 1 - S U - WA - 2 4

1

Due to various constraints, some options may not be combined with others.

Please consult your Cooper Lighting Representative for availability. 

Series

701IW

=Nimbus II

Wall Mount

701IW

Optics Up

S

=Specular

S

Number of Lamps

(not included)

1

=1 Lamp

2

Lamp Type

(Length)

T8

=32W

(4' Unit)

T8

Number of

Circuits

1

1

=1 Circuit

1

Voltage

1

1

=120V

2

=277V

3

=347V

SU-WA

= Surface/Wall 

Mount

SU-WA

Run Length

Individual or

continuous runs will

be configured with

4' and 8' sections only
(see sample catalog #)

Wiring

1

C

=Standard Circuit

D

=Dimming

E

=Emergency/Night Light

B

=Battery Pack

Optics Down

P

=Perforated

P

U

= Universal

2

=2 Lamps

NEO-RAY