Width
2
=2' Width
P
ARALUX II, III, IV
, V SURF
ACE
413
COOPER LIGHTING
• Equipped with energy sav-
ing ballasts/complies with
federal energy efficiency
standards
• Computer designed, preci-
sion cell louver technology
• Low iridescent louver ma-
terial minimizes irides-
cence (MI)
• System complies with RP-1
and meets today’s lighting
and energy management
standards (2P5MX)
• Die formed housing
• Full seam welded corners
• Self locking spring loaded
cam latches/positive hinges
• UL/CUL Listed. Suitable for
damp locations.
PMX
SERIES
2 ' x 2 ' , 2 ' x 4 ' ,
2 , 3 o r 4 L a m p
P a r a b o l i c L o u v e r
PA R A L U X V, I V, I I I , I I
S U R FA C E M O D U L A R
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : 2 E P 3 M X - 2 3 2 S 2 8 I - 1 2 0 V- E B 8 1 - U
D E S C R I P T I O N
The Paralux V series features a “pro-
prietary “Total Light Control System”
that has been designed to eliminate
glare reflections in VDT screens. The
Paralux V series luminaire incorporates
a precision cut-off parabolic louver in a
surface mount modular fixture. The lu-
minaire is the ideal solution for com-
puter environments and open office
areas. The high comfort Paralux IV and
high performance Paralux III series in-
corporate a 4" or 3" precision cell lou-
ver into a nominal 6-11/16" deep
modular fixture housing. The Paralux
IV and Paralux III series are excellent
choices for commercial office spaces,
schools, hospitals or retail merchandis-
ing areas.
Voltage
(1)
120V
=120 Volt
277V
=277 Volt
347V
=347 Volt
UNV
=Universal Voltage 120-277 Volt
(2)
EP
=Paralux
Louver (III)
P
=Paralux Lou-
ver (II, IV, V)
Louver Depth
(Leave Blank for Paralux IV)
2
=Paralux II
3
=Paralux III
Blank
=Paralux IV
5
=Paralux V
MX=
Surface
Mount/Floating Louver
Number of
Lamps
2, 3, or 4
lamps
(Not included)
Wattage (Length)
U3
=40W T12 (24")
U6
=40W T12 (24")
U6T8
=31W T8 (24")
U15/8
=31W Octron
T8 (24")
BX40
=40W Biaxial T5
(24")
20
=20W T12 (24")
17
=17W T8 (24")
40
=40W T12 (48")
32
=32W Octron T8
(48")
Louver Color
S
=Silver
W
=White
Cell Configuration
See Recessed Parabolic pages for
applicable louver configurations.
Louver Finish
H
=Semi-Specular/Haze (Gold only)
I
=Semi-Specular/Haze (Low Iridescent)
Standard
MI
=Specular/Mirrored (Low Iridescent)
P
=Painted
NOMINAL SIZE
A
B
2' x 2'
24" (610mm)
6-11/16" (170mm)
2' x 4'
24" (610mm)
6-11/16" (170mm)
D I M E N S I O N S
Options
GL
=Single Element Fuse
GM
=Double Element Fuse
Emergency
- for EM installed, see EM options table
Ballast Type
(1)
Blank
=Standard Magnetic Ballast (Biax & 20W)
EB5
= T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
LE3
=T12 Magnetic Energy Saving
EB2
=T12 Electronic Rapid Start.
ER8
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB8
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS
= T8 Electronic Instant Start. High
Ballast Factor >1.13.
Total Harmonic Distortion < 20%
TEB5
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
DLS
=Digital Lighting System Dimming
(For complete details on generic or to specify manufac-
turer’s ballast see pg. 469)
No. of Ballast
1, 2 or 3
No. of
Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1, 2 or 3
No. of Ballast
1 or 2
Options
(See Options Section)
Packaging
U
=Unit Pack
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Rep-
resentative for availability and ordering information.
COOPER LIGHTING - METALUX
®