These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.

INSTALLATION INSTRUCTIONS

IMPORTANT:

Read carefully before installing fixture. Retain for future reference.

VAPOR-TIGHT
WALL MOUNT

5/01

IMI-447

LUMARK             

1121 HIGHWAY 74 SOUTH PEACHTREE CITY,  GEORGIA  30269

5/01

IMI-447

ADH010709

FIXTURE

BLACK

LINE (HOT)

WHITE

NEUTRAL

GROUND

GREEN/GROUND

For Models:
ICVW1 Series
(200 Watt / 120 Volt) 1/2 NPS
ICVW2 Series
(300 Watt / 120 Volt) 3/4 NPS

Instructions:

Disconnect all electrical power from the source as per the 
NEC.

Turn off and lock circuit breakers and remove fuses
protecting the circuit.

Complete connections as per the diagram and the NEC 
using approved methods and devices. Proper grounding 
must include ground screw and ground wire.

A surface mounted fixture requires the use of caulking 
compounds to provide a moisture tight seal. Use RTV 
silicone sealant.

Relamp with proper wattage lamp only -- allow fixture to 
cool for relamping.

Lamps: (Sizes vary by manufacturer, so caution must 
be taken with Max Lamp Sizes stated.)
ICVW1: 200W MAX; A21 MAX; 120V MIN
ICVW2: 300W MAX; PS25 MAX; 120V MIN

Min Supply Conductor Requirements.

ICVW1: 75ºC
ICVW2: 90ºC

Applications:

• Suitable for operation in Ambients not exceeding 40ºC.
• Suitable for Wet Locations.

Warning:

FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN 
SERIOUS INJURY OR DEATH

• This fixture is not suitable for Hazardous

or Classified Locations. Disconnect all
electrical power before installation or 
servicing.

• Not for use above cooking equipment.

• This product must be installed in 

accordance with the applicable installation 
code by a person familiar with the
construction and operation of the product 
and the hazards involved. Consult a
qualified electrician to ensure correct 
branch circuit conductor.

Not Required in
Some Applications

Mounts to Standard
J-Boxes when
Desired.

Ground Screw
Connection when
Standard J-Box
Desired

Ground Screw