Cooper Lighting FAIL-SAFE MPWC Скачать руководство пользователя страница 1

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

04/15/2007 12:56:42 PM

Consult your representative for additional options and finishes.

Specifications and Dimensions subject to change without notice.

ADC041675

LAMP CONFIGURATIONS

MOUNTING DIMENSIONS

DESCRIPTION

Fail-Safe's MPWC series combines a multi-function, wall mounted fixture 
with contemporary styling. Through innovative features, the MPWC 
accommodates multiple applications throughout the healthcare 
environment. One fixture supplies the patient room with task lighting, 
offering practical solutions to the patient and medical staff for everyday 
tasks. The MPWC is separated into two compartments: up light for general 
ambient room lighting and down light for reading/direct task lighting to 
accommodate the needs of the patient or healthcare professional. The 
fixture is UL listed.

Application

The MPWC is designed for use in 
healthcare environments, 
specifically for use in patient 
rooms over beds to facilitate all of 
the tasks required by the patient 
and medical staff. The MPWC's 
aesthetics make it ideal for other 
applications such as over vanities, 
rest rooms, and hallways.

A ... Lens

Up light: .125" thick, prismatic K12 
pattern, acrylic lens is standard 
(prisms on the inside for ease of 
cleaning). Down light: .125" thick, 
prismatic K12 pattern, acrylic lens 
is standard (prisms inside).

B ... Fasteners

Nickel-plated thumbscrews are 
standard (requires no tools to 
remove lens assembly).

C ... Construction

Outer housing is 18 gauge, 
die-formed, cold rolled steel with 
seam-welded ends. Back pan 
housing is 20 gauge, die formed 
cold rolled steel. Power tray and 
reflector are 20 gauge cold rolled 
steel.

D ... Lamps

T8 Linear Fluorescent
T5 HO Linear Fluorescent

E ... Ballast  Options

T8 Electronic Instant Start
T5 Electronic Programmed Start 
T8 Magnetic-HPF

F ... Finish

High gloss white polyester powder 
coat finish is standard on exterior 
housing. A multistage cleaning and 
painting process is utilized. Interior 
reflector is high reflectance white, 
minimum reflectance 92%. Custom 
colors are available.

Labels

UL/cUL Listed for Damp Locations

MPWC

34W - 216W

Fluorescent

CONTEMPORARY

HEALTHCARE

WALL MOUNTED

LUMINAIRE

C     

D

E

B

A

6”

[153mm]

6 1/2”

[165mm]

1 7/8”

[47MM]

1 7/8”

[47MM]

1 7/8”

[47MM]

1 7/8”

[47MM]

24 3/8”[620mm]

36 3/8”[925mm]

22”[559mm]

34”[864]

20”[508mm]

8”[203mm]

6 1/16”

[154mm]

6 1/16”

[154mm]

6 1/16”

[154mm]

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

3/16 X 11/16”

[4.8 X 17.5mm]

Keyhole Mtg. Holes

2 1/4”

[57mm] Dia.

Access Hole

2 1/4”

[57mm] Dia.

Access Hole

2 1/4”

[57mm] Dia.

Access Hole

48 3/8”[1229mm]

46”[1168mm]

32”[813mm]

16”[406mm]

E N E R G Y   DATA  

Input Watts:

T5HO Fluorescent Lamps

Electronic Ballasts*

(2) 24W T5 HO Lamps: 54W

(3) 24W T5 HO Lamps: 79W

(4) 24W T5 HO Lamps: 104W

(2) 39W T5 HO Lamps: 80W

(3) 39W T5 HO Lamps: 127W

(4) 39W T5 HO Lamps: 174W

(2) 54W T5 HO Lamps: 124W

(3) 54W T5 HO Lamps: 182W

(4) 54W T5 HO Lamps: 240W

*Energy Data calculated using 

2 ballasts per each lamp

configuration. (Programmed start,

normal light output, average ballast

factor 0.95 to 1.1)

T8 Fluorescent Lamps

Electronic Ballasts*

(2) 17W T8 Lamps: 40W

(3) 17W T8 Lamps: 54W

(4) 17W T8 Lamps: 68W

(2) 25W T8 Lamps: 54W

(3) 25W T8 Lamps: 74W

(4) 25W T8 Lamps: 94W

(2) 32W T8 Lamps: 64W

(3) 32W T8 Lamps: 90W

(4) 32W T8 Lamps: 116W

*Energy Data calculated using 

2 ballasts per each lamp

configuration. (Instant start, normal

light output, average ballast factor

0.9 to 1.0)

FAIL-SAFE

®

Содержание FAIL-SAFE MPWC

Страница 1: ...old rolled steel Power tray and reflector are 20 gauge cold rolled steel D Lamps T8 Linear Fluorescent T5 HO Linear Fluorescent E Ballast Options T8 Electronic Instant Start T5 Electronic Programmed Start T8 Magnetic HPF F Finish High gloss white polyester powder coat finish is standard on exterior housing A multistage cleaning and painting process is utilized Interior reflector is high reflectanc...

Страница 2: ... emergency generator systems Test switch and indicator light will be installed on top of unit in middle of the power tray Not available with all options consult customer service FNL Fluorescent night light 2 pin G23 Base 7 or 9w twin tube lamp installed in center of upper compartment of fixture uses a magnetic ballast FNL is wired on a separate circuit Lamps by others GCO Grounded convenience outl...

Страница 3: ...ighway 74 South Peachtree City GA 30269 TEL 770 486 4800 FAX 770 486 4801 04 15 2007 12 56 42 PM Specifications and Dimensions subject to change without notice ADC041675 ORDERING INFORMATION LNL LED Night Light 50 000 hrs provided by Cooper ...

Страница 4: ...6 34 35 31 30 27 26 24 22 41 37 33 30 35 31 29 30 26 27 23 23 21 19 38 32 28 25 31 27 24 27 22 24 20 21 18 16 35 29 25 22 27 24 21 24 19 21 17 19 15 14 32 26 22 19 25 21 18 22 17 19 15 17 14 12 30 24 20 17 22 19 16 20 15 18 13 16 12 11 28 21 18 15 20 17 14 18 13 16 12 14 11 10 26 20 16 13 19 15 13 17 12 15 11 13 10 09 24 18 14 12 17 14 12 15 11 14 10 12 9 08 rc Ceiling reflectance rw Wall reflecta...