Fail-Safe's hospital patient room of the future - the MPR removes lighting 
elements from walls incorporating them into a multi-compartment ceiling 
fixture. Sections provide independent task illumination: patient reading light 
using (1) 40W biaxial lamp puts the light at the head of the bed for patient 
use; ambient room light using (2) 40W biaxial lamps provides soft illumi-
nation via perforated wings while shielding direct source glare; examination 
light uses (3) 40W biaxial lamps and focuses high intensity illumination to 
torso for maximum patient appraisal with minimal wattage consumption. 
The system is designed for 1, 2, or 3 feeds potentially reducing the overall 
installed cost. Also available for 50W biaxial lamps.

Mounting

Recessed Grid or Flange, Ceiling 
Mount (supported from above)

Lamps

(By Others)

Ballast

Standard, Class P, CBM/ETL 
Ballast, (3) circuit wiring.

Housing

Die-formed, 20 ga. cold rolled 
steel.

Features

- 20 gauge CRS housing is formed 
  fabricated for maximum strength 
  and stability.
- Each compartment is designed to 
  provide a specific illumination 
  function while allowing for 
  commonality of branch circuit 
  feeding.
- High efficiency biaxial lamps 
  provide excellent color 
  rendering ability and high 
  lumen output for nominal 
  wattage draw.

Finish

Low gloss, electrostatically 
applied, baked white powder 
polyester-finish.

Shielding

(READING LIGHT) Die formed lamp 
shield. 
(AMBIENT LIGHT) Formed 
perforated metal.
(EXAM LIGHT) Pattern 12 Acrylic 
Ribbed lens.

Labels

U.L. Listed, C.S.A. Certified.

MPR

MPR2

AMBIENT/DIRECT

Multi-Compartment

Patient Room

Recessed Luminaire

2' x 4' Fluorescent Grid

2' x 4' Fluorescent Flange

E N E R G Y   D A TA

Input Watts:
Electronic Ballasts and 

Standard Lamps

(6) 40W Biaxial Fluorescents: 204W

(6) 50W Biaxial Fluorescents: 264W

S A M P L E   N U M B E R :   M P R 2 - G - 6 4 0 B X - 1 2 0 - E B X 3

Product Family

MPR2

= 2 Compartment

Medical Patient

Room Recessed

Luminaire Exam

& Ambient

Section

MPR

= Standard 3

Compartment

Medical Patient

Room Recessed

Luminaire

Reading, Exam

& Ambient

Section

Voltage

120

=120V

277

=277V

347

=347V

UNV

=120V through 277V

Options

EBP

=Emergency

Battery Pack

FNL

=Fluorescent

Night Light

(Lamp by others) 

GLR

=Fuse and Holder

RIF

=Radio

Interference

Filter

LVRELAY

=Low

Voltage Relay

Ballast
EBX3

=(3) Ballasts for use with biaxial lamps

EBX4

=(4) Ballasts for use with biaxial lamps 

1

Lamp Type

Biaxial Fluorescents 

640BX

=(6) 40W Lamps

650BX

=(6) 50W Lamps

Ceiling
Type

G

=Grid

F

=Flange

Ambient Options

If no option is chosen, then 

Standard 2 Basket Ambient

will be provided.

SCPB

=Single Perf Basket Centered

SSCB

=Single Sealed Lamp

Accessories

(order

separately)

MPR-GGO-1

=Full

Clear Poly Lens

Door. No Acrylic

Over Exam Hinged Door

2

MPR-GGD-2

=Two

Compartment MPR

(Lens Poly and Acrylic)  

MPR-GGD-3

=Three

Compartment MPR

Hinged Door (Lens

Poly and Acrylic) 

2

2

6” [153mm]

6” [153mm] MAX FROM WALL

24” [610mm]

48” [1219mm]

24” [610mm] wide

18” [457mm]

6 1/4”

[159mm]

AMBIENT LIGHT

READING

LIGHT

EXAM

LIGHT

3   C O M PA R T M E N T   M O U N T I N G

2   C O M PA R T M E N T   M O U N T I N G

3   C O M PA R T M E N T   D I M E N S I O N S

2   C O M PA R T M E N T   D I M E N S I O N S

24"

(4) 5/16" Mounting Holes

ø .875 

Knockout

6”

max.

6 1/4"

20 3/8"

44 1/8"

24" x 48" C to C

Runs Ambient Section

Exam Light

Runs Exam Section

FAIL-SAFE

®