Cooper Lighting AMETRIX C-Scroll P4R Скачать руководство пользователя страница 1

Exploded view and part call-out

Canopy

Set screw

1/4-20 x 4 1/2"

 Hex cap bolts

(4x)

(by others)

J-box

#8-32 x3/8"

(2x)

(4x)

1/4" Fastener

Cover plate

Wiring the fixture

1.

  Remove all 1/4-20 x4 1/2" hex bolts from bottom of pendant. 

2.

  Remove both #8-32 x 3/8" set screws and allow canopy to 

     slide down pendant.

3.

  Run wires from J-box into pendant, ensure there is enough 

     wire to reach cover plate.

4.

  Using appropriate fasteners, secure fixture to ceiling.  

Use 

     additional bracing around J-box to support fixture.
5

.  Replace canopy and secure using both set screws.   

Yoke arm 

indicator

Aiming the fixture

Fixture head 

indicator

1.

  To aim fixtures, loosen both #10-32 end screws on 

one

 

     fixture.  When both indicators are lined up, the slope of the 

     lens face is 40-degrees.  Each subsequent notch is an 

     addi/- 10-degrees.

2.

  When fixture head is rotated to the desired angle, retighten 

     end screws to secure the position.  

3.

  Repeat for remaining fixture heads.

Set screw

Mounting pendant to J-box

(4x)

(by others)

1/4" fasteners

(by others)

J-box

(2x)

(4x)

Hex cap bolts

1/4-20 x4 1/2"

#8-32 x3/8"

Canopy

Cover plate

Use additional bracing 
around J-box to support 
fixture.

4.

Cover plate

  Push connections into pendant and secure cover plate.

     properly matched.

1/4-20 x4 1/2"

Fixture wire 

Hex cap bolts
(4x)

1.

  With pendant secure, slide fixture assembly onto pendant 

     and secure with four 1/4-20 x4 1/2" hex bolts.

2.

  Remove cover plate and insert wires from fixture heads into 

     pendant and pull through opening.

3.

  Attach appropriate wires and ensure all connections are 

Attention:

Quad fixture assemblies require additional bracing/structure

around J-box to support fixture.

2

that all sources of power are turned off.  All 

Sheet 1 of 2

performed by a certified electrician.  

ADY071466   REV B(ECN80481)

 

Warning

:  Before starting any work ensure 

work must meet local/national codes and be 

Do not

mount fixtures vertically. 

Installation Instructions

Vault

C-Scroll

Roundel

These installation instructions are valid with the above Ametrix styles.

1