SAVE THESE INSTRUCTIONS.

MOUNTING AND WIRING YOUR FIXTURE

 

WARNING: Risk of electric shock. Disconnect 

 

power at fuse or circuit breaker before installing 

 

or servicing.

NOTE:

 This fixture is intended to be conduit connected to a properly installed and properly 

grounded metal weatherproof junction box (not included). All conduit connectors, conduit, 

and junction boxes (sold separately) should be cULus Listed suitable for wet locations. 

1.  Turn off the power at the main fuse/breaker box. 

2.  Using the pattern on the box, mark and drill holes 

for mounting. 

Note:

 Mount this fixture in an upright 

and level position. 

3.  Install the two bottom mounting screws (C) first, 

leaving enough room between the mounting 

screws and the mounting surface to accommo-

date mounting the fixture. 

4.  Screw the top mounting screw (C) into the 

predrilled hole and back the screw out. This will 

leave the hole threaded and make installation of 

the fixture easier. 

5.  Remove the cover plate by loosening the two 

mounting screws (F) inside the cover plate. 

6.  Remove access cover (B) from fixture (A). Install 

the first conduit connector and conduit (sold 

separately) into the access cover (B) (Fig. 1). 

7.  Feed supply wires into conduit. Attach ground 

wire that is attached to fixture housing (A) to the 

junction box earth ground wire. 

8.  Connect the black fixture wire to the black supply 

wire (hot) with UL-approved wire connector (E). 

Connect the white fixture wire to the white supply 

wire (neutral) with UL-approved wire connector (E). 

9.  Attach access cover (B) to the light fixture (A) 

using the 2 access cover mounting screws (F) 

provided (Fig. 1). 

Note: 

Make sure all wiring is 

placed into the arm prior to tightening the access 

cover screws to avoid pinching the wires. 

10.Place the fixture (A) on the two lower mounting 

screws (C) and install the upper mounting screw 

(C). Tighten all mounting screws to secure the 

fixture (A). 

11.Reinstall the cover plate, making sure to tighten 

the two screws to secure the lens to the fixture (A).

12.Connect second conduit and conduit connector 

to the junction box (sold separately). 

 

Note:

 This fixture can be mounted on 1-5/8 in. 

outside diameter extension arms (not provided). 

When installing fixture onto an extension arm, 

remove the access cover (B) and use the included 

pole mounting clamp (D) and access cover 

mounting screws (F) (Fig. 2). 

13.Turn power back ON.

OPTIONAL: INSTALLING THE DROP REFRACTOR

1.

 Install the Drop Refractor (G) using the 2 drop 

refractor mounting screws (H) in the parts bag. 

Be careful to not overtighten the screws or use 

power tools to tighten the screws. 

NOTE: 

If the fixture is Energy Star Certified, installing 

the drop refractor will violate the fixture’s 

 

Compliance.

TROUBLESHOOTING

  Problem

  

Cause / Solution

Light Does Not 

Come On or light 

comes on for only 

a few seconds

Light cycles 

 

ON and OFF 

 

continuously

Light does not 

 

shut off during 

daytime

No power to the fixture.

  •  Check if circuit breaker tripped.

  •  Confirm wall switch is ON.

 

Fixture is sensing daylight.

  •  Cover Photocontrol sensor. Unit will switch ON after a short delay.

TURN OFF POWER BEFORE CONTINUING

Wiring to the unit is loose.

  •  Confirm wiring is properly secured.

    * If light still does not come on after checking wiring 

      connections, contact Customer Service.

Photocontrol sensor is sensing reflected light.

  •  Cover Photocontrol sensor with a piece of black electrical 

    tape. The fixture should turn on after a slight delay. This

 

    means that extraneous or reflected light from the fixtures

 

    causing the sensor to turn the unit off. Reflected light could 

    be coming from mounting the fixture too close to walls or

 

    other objects that will throw the light into the sensor.  

    Relocate light fixture away from the object that was 

 

    reflecting light so it no longer cycles on and off. 

Photocontrol sensor is in a shaded area.

  •  Shine a flashlight into the Photocontrol sensor. If the light

 

    turns off, the fixture is mounted in an area that does not

 

    allow enough light to enter the Photocontrol sensor 

5-YEAR LIMITED WARRANTY

THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 

WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

Cooper Lighting Solutions warrants to customers that, for a period of five years from the date 

of purchase, Cooper Lighting Solutions products will be free from defects in materials and 

workmanship. The obligation of Cooper Lighting Solutions under this warranty is expressly 

limited to the provision of replacement products. This  

warranty is extended only to the original purchaser of the product. A purchaser’s receipt or 

other proof of date of original purchase acceptable to Cooper Lighting Solutions. This is re-

quired before warranty performance shall be rendered. This warranty does not apply to Coo-

per Lighting Solutions products that have been altered or repaired that have been subjected 

to neglect, abuse, misuse or accident (including shipping damages). This warranty does not 

apply to products not manufactured by Cooper Lighting Solutions which have been supplied, 

installed, and/or used in conjunction with Cooper Lighting Solutions products. Damage to the 

product caused by replacement bulbs or corrosion or discoloration of brass components are 

not covered by this warranty. 

LIMITATION OF LIABILITY:

IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT, 

INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, 

WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR 

FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY 

CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANU-

FACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER 

LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, 

EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTION PRODUCTS GIVING RISE 

TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES. 

To obtain warranty service, please contact Cooper Lighting Solutions, at 1-800-334-6871, 

press option 2 for Customer Service, or via e-mail [email protected] 

and include the following information:

• Name, address and telephone number

• Date and place of purchase

• Catalog and quantity purchase

• Detailed description of problem

All returned products must be accompanied by a Return Goods Authorization Number issued 

by the Company and must be returned freight prepaid. Any product received without a Return 

Goods Authorization Number from the Company will be refused. Cooper Lighting Solutions is 

not responsible for merchandise damaged in transit. Repaired or replaced products shall be 

subject to the terms of this warranty and are inspected when packed. Evident or concealed 

damage that is made in transit should be reported at once to the carrier making the delivery 

and a claim filed with them.  

Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited. 

 

For assistance, call 1-800-334-6871 or e-mail us at [email protected]

Printed in China

2

CONDUIT CONNECTOR

CONDUIT

E. WIRE CONNECTORS

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

E

F

E

F

D

ALS Integrated Photocell

Instruction Sheets Figures

-

1.065 LB

29.468 IN3

1

L MOD: E0439882

7/10/2020

ALS Integrated Photocell Instruction Sheets Fi

gures

TOLERANCE

GENERAL

S

DIMENSIONS THAT AFFECT

SAFE HANDLING OR

OPERATION

818.746 IN2

DEV/ZINT NO:

1 OF

ANGLES

± 1.0 °

ALL

PRODUCT MUST CONFORM TO ROHS

COOPER LIGHTING SOLUTIONS - CONFIDENTIAL AND PROPRIETARY

NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION

THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS

CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON, AND IS MERELY ON LOAN

AND SUBJECT TO RECALL BY COOPER LIGHTING SOLUTIONS AT ANY TIME. BY TAKING POSSESSION

OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT

BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF COOPER LIGHTING SOLUTIONS,AND THAT

NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE

PRIOR WRITTEN CONSENT OF COOPER LIGHTING SOLUTIONS. IN THE CASE OF CONFLICTING

CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.

Cooper Lighti

ng  SolutionsTemplate Rev -

IP LEVEL:

REVISIONS

REV.

DESCRIPTION

DATE

CHANGE_NUMBER

BY

APPROVED

FIGURE 1

B. ACCESS COVER

A. LIGHT FIXTURE

G. DROP REFRACTOR

C. MOUNTING SCREWS

D. POLE MOUNTING CLAMP

F. POLE MOUNTING CLAMP/ACCESS COVER MOUNTING SCREWS

2.125

[54]

1.375

35

2.750

[70]

USE FOR PACKAGING ARTWORK

H. DROP REFRACTOR MOUNTING SCREWS

FIGURE 2

THIRD ANGLE PROJECTION

MATERIAL:

METRIC (MM)

ENGLISH (IN)

.X

.XX

.XXX
.X

.XX

.XXX

DIMENSIONS ARE IN INCHES

DIMENSIONS IN [ ] ARE IN MM

ELECTRONIC CAD DRAWING.  DO

NOT REVISE MANUALLY.

SURFACE AREA:

DO NOT SCALE DRAWING

DRWN:

DATE

APPROVALS

± 0.040

± 0.020

± 0.010
± 1

± 0.5

± 0.25

x.x

x.x

DENOTES CRITICAL

DIMENSIONS AND

GAUGE CHECK POINTS

DENOTES FIRST PIECE

AND IN-PROCESS

INSPECTION

DENOTES FIRST

PIECE

INSPECTION ONLY

F

P

PART NUMBER

TITLE:

SIZE:

DWG NO:

REV:

SHEET

VOL:

WT:

SCALE:

FINISH:

APPR:

CHKD:

C

1

CONDUIT CONNECTOR

CONDUIT

E. WIRE CONNECTORS

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

E

F

E

F

D

ALS Integrated Photocell

Instruction Sheets Figures

-

1.065 LB

29.468 IN3

1

L MOD: E0439882

7/10/2020

ALS Integrated Photocell Instruction Sheets Fi

gures

TOLERANCE

GENERAL

S

DIMENSIONS THAT AFFECT

SAFE HANDLING OR

OPERATION

818.746 IN2

DEV/ZINT NO:

1 OF

ANGLES

± 1.0 °

ALL

PRODUCT MUST CONFORM TO ROHS

COOPER LIGHTING SOLUTIONS - CONFIDENTIAL AND PROPRIETARY

NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION

THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS

CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON, AND IS MERELY ON LOAN

AND SUBJECT TO RECALL BY COOPER LIGHTING SOLUTIONS AT ANY TIME. BY TAKING POSSESSION

OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT

BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF COOPER LIGHTING SOLUTIONS,AND THAT

NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE

PRIOR WRITTEN CONSENT OF COOPER LIGHTING SOLUTIONS. IN THE CASE OF CONFLICTING

CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.

Cooper Lighti

ng  SolutionsTemplate Rev -

IP LEVEL:

REVISIONS

REV.

DESCRIPTION

DATE

CHANGE_NUMBER

BY

APPROVED

FIGURE 1

B. ACCESS COVER

A. LIGHT FIXTURE

G. DROP REFRACTOR

C. MOUNTING SCREWS

D. POLE MOUNTING CLAMP

F. POLE MOUNTING CLAMP/ACCESS COVER MOUNTING SCREWS

2.125

[54]

1.375

35

2.750

[70]

USE FOR PACKAGING ARTWORK

H. DROP REFRACTOR MOUNTING SCREWS

FIGURE 2

THIRD ANGLE PROJECTION

MATERIAL:

METRIC (MM)

ENGLISH (IN)

.X

.XX

.XXX
.X

.XX

.XXX

DIMENSIONS ARE IN INCHES

DIMENSIONS IN [ ] ARE IN MM

ELECTRONIC CAD DRAWING.  DO

NOT REVISE MANUALLY.

SURFACE AREA:

DO NOT SCALE DRAWING

DRWN:

DATE

APPROVALS

± 0.040

± 0.020

± 0.010
± 1

± 0.5

± 0.25

x.x

x.x

DENOTES CRITICAL

DIMENSIONS AND

GAUGE CHECK POINTS

DENOTES FIRST PIECE

AND IN-PROCESS

INSPECTION

DENOTES FIRST

PIECE

INSPECTION ONLY

F

P

PART NUMBER

TITLE:

SIZE:

DWG NO:

REV:

SHEET

VOL:

WT:

SCALE:

FINISH:

APPR:

CHKD:

C

CONDUITCONNECTOR

CONDUIT

Содержание HALO ALS4A40GY

Страница 1: ...ATE APPROVALS 0 040 0 020 0 010 1 0 5 0 25 x x x x DENOTES CRITICAL DIMENSIONS AND GAUGE CHECK POINTS DENOTES FIRST PIECE AND IN PROCESS INSPECTION DENOTES FIRST PIECE INSPECTION ON F P PART NUMBER TITLE SIZE DWG NO SHEET VOL WT SCALE FINISH APPR CHKD C E WIRE CONNECTORS H DROP REFRACTOR MOUNTING SCREWS D C B A 1 2 3 E F D ALP Instruction Sheets Figures 2 113 LB 58 477 IN3 1 L MOD E0439882 7 10 20...

Страница 2: ...IRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT STRICT LIABILITY OR IN TORT INCLUDING NEGLIGENCE NOR FOR LOST PROFITS NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANU FACTURE SALE DELIVERY USE MAINTENANCE REPAIR OR MODIFICATION OF COOPER LIGHTING SOLUTIONS PRODUCTS O...

Страница 3: ...accordez le luminaire à une source d alimentation de 120V 60 Hz Tout autre rac cord annulera la garantie L appareil d éclairage doit être installé par des personnes ayant l expérience du câblage domestique ou par un électricien qualifié Le système électrique et la mé thode de raccordement électrique de l appareil d éclairage doivent être conformes au Code national de l électricité et aux codes loc...

Страница 4: ...N ÀL ENTRETIEN ÀLARÉPARATION OU ÀLAMODIFICATIONDEPRODUITSCOPPERLIGHTINGSOLUTIONS OUÀLAFOURNITUREDETOUTE PIÈCEDERECHANGECONNEXE LECOÛT DES DOMMAGES NE PEUT DÉPASSER LE COÛT D ACHAT DU PRODUIT COOPER LIGHTING SOLUTIONS FAISANT L OBJET DE LA RÉCLAMA TION AU TITRE DE LA PRÉSENTE GARANTIE AUCUN FRAIS DE MAIN D OEUVRE NE SERA REMBOURSÉ POUR ENLEVER OU INSTALLER UN LUMINAIRE Pour faire une réclamation au...

Страница 5: ...onecte el cable negro de la luminaria al cable de alimentación negro vivo con un conector de cables aprobado por UL E Conecte el cable blanco de la luminaria al cable de alimentación blanco neutro con un conector de cables apro bado por UL E 9 Fije la cubierta de acceso B a la luminaria A uti lizando los dos tornillos de montaje de la cubierta de acceso F provistos Fig 1 Nota Asegúrese de colocar ...

Страница 6: ...CONTRACTUAL INCLUYENDO LANEGLIGENCIA TAMPOCO DE LA PÉRDIDA DE GANANCIAS COOPER LIGHTING SOLUTIONS TAMPOCO SERÁ RESPONSABLE DES O DAÑOS QUESURJANOESTÉNCONECTADOSCONESTOSTÉRMINOSOCONLAFABRICACIÓN VENTA ENTREGA USO MANTENIMIENTOM REPARACIÓN O MODIFICACIÓN DE LOS PRODUCTOS DE COOPER LIGHTING SOLUTIONS O DEL SUMINISTRO DE CUALQUIER PIEZA DE REPUESTO QUEEXCEDAELPRECIODECOMPRA DE LOS PRODUCTOS DE COOPER ...

Отзывы: