background image

Installation Instructions – Fail Safe Narrow (FSN)
Instructions d’installation

 

– Fail Safe Narrow (FSN)

Instrucciones de instalación

 

– Fail Safe Narrow (FSN)

WARNING

IB51915121

Fail-Safe

DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may 

arise from the improper, careless, or negligent installation, handling or use of this product.  
IMPORTANT: Read carefully before installing fixture. Retain for future reference.  
NOTICE: These instructions do not claim to cover all details or variations in the equipment, procedure, or process 

described, or to provide directions for meeting every possible contingency during installation, operation or maintenance. 

When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your 

nearest representative.
NOTICE: Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation 

section.
NOTICE: Fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
GENERAL: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention 

of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to 

assure you have received the correct merchandise.

Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product 

must be performed by a qualified electrician. This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and operation of the product and hazards 

involved. 
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any 

maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Minimum 90°C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Must be very careful if power tools are used to install the fixture. Uncontrolled torque setting may lead to 

thread/gasket damage or lens breakage.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.

Содержание Fail Safe Narrow

Страница 1: ...nd dimensions subject to change without notice GENERAL Upon receipt of fixture thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier Compare the ca...

Страница 2: ...for power supply wiring Figure 1 Figure 2 Figure 3 Figure 4 6 Grid clips are provided for additional retention to ceiling system Orient tabs on back of fixture over T GRID by bending tabs up 90 degree...

Страница 3: ...erence NFPA70 2020 NEC section 410 69 7 Bring supply wires into the junction box using a conduit fitting through the top access plate Connect the line black and neutral white to the supplied quick dis...

Страница 4: ...1 With the fixture positioned in the grid press included L Bracket to the back plate of the fixture and fasten it to the grid using included self drilling screw 2 Reference images below for the locati...

Страница 5: ...dereau de marchandises avec l tiquette du luminaire sur le boitier pour confirmer la r ception de la bonne marchandise Risque d incendie de d charge lectrique de coupure ou d autres risques L installa...

Страница 6: ...10 V gris Dans ce cas l installateur tiquettera le fil gris comme un fil de gradation de 0 10 V et le connectera au fil de commande de la gradation de 0 10 V rose de notre produit R f rence dispositi...

Страница 7: ...mens et le TC souhait s ont t s lectionn s fixez solidement le couvercle de l interrupteur fourni l aide des vis fournies Figure 8 11 Pour nettoyer le luminaire utilisez une petite quantit d eau et un...

Страница 8: ...del recibo de env o con la etiqueta de la luminaria que se encuentra sobre la carcasa para asegurarse de que recibi la mercanc a correcta Riesgo de incendio descarga el ctrica cortes u otros riesgos...

Страница 9: ...ganchos de la grilla Figura 4 ota N Esta luminaria es compatible con una regulaci n de 0 10 V Al instalar cables de regulaci n siga las instrucciones de su regulador para el cableado a los terminales...

Страница 10: ...configuraci n 10 Una vez que se han seleccionado el nivel de l menes deseado y el CCT fije la cubierta del interruptor provista de forma segura usando los tornillos suministrados Figura 8 11 Para limp...

Страница 11: ...t the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help nonc de la FCC Remarque Cet quipeme...

Отзывы: