Cooper & Hunter CH-S09FTXHV-B Скачать руководство пользователя страница 1

МОДЕЛИ:

 

 

CH-S09FTXHV-B

CH-S12FTXHV-B

CH-S18FTXHV-B

Split Air Conditioner

Vip Inverter Series

OWNER’S MANUAL

EN

Designed by Cooper&Hunter International Corporation, Oregon, USA

www.cooperandhunter.com

F

or proper operation

,

 please read and 

k

eep this manual carefully.

Содержание CH-S09FTXHV-B

Страница 1: ...B CH S18FTXHV B Split Air Conditioner Vip Inverter Series OWNER S MANUAL EN Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com For proper operation please read and...

Страница 2: ...trol The remote controller shall be matched with the air conditioner before operation otherwise the remote control will be invalid Before operation please read the instructions in this page carefully...

Страница 3: ...tion 33 Installation Installation of indoor unit 34 Vacuum pumping 39 Leakage detection 39 Check after installation 40 Test and operation Test operation 40 Attachment 41 Pipe expanding method Configur...

Страница 4: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 5: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 6: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Страница 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Страница 8: ...cate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner...

Страница 9: ...e Indoor Unit air inlet panel filter power wire horizontal louver remote controller air outlet tem display power display NOTICE Actual product may be different from above graphics please refer to actu...

Страница 10: ...idity button Health button Air button 10 T ON T OFF button 8 Mode button 5 Fan button battery power Send signal 8 heating function I feel function Set fan speed Temp display type Set temp Outdoor ambi...

Страница 11: ...will change accordingly Temperature can t be adjusted under auto mode Introduction for buttons on remote controller Note After putting through the power the air conditioner will give out a sound Oper...

Страница 12: ...as below I FEEL button 6 Press this button to start I FEEL function and will be displayed on the remote controller After this function is set the remote controller will send the detected ambient tempe...

Страница 13: ...eating mode the air conditioner operates under heat mode Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle Cooling only unit won t...

Страница 14: ...esumes displaying Cancel T OFF Under the condition that T OFF is started up press T OFF button to cancel it Note Under on and off status you can set T OFF or T ON simultaneously Before setting T ON or...

Страница 15: ...OOL or DRY mode the icon is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit After energization X FAN OFF is...

Страница 16: ...on the features of siesta press AIR button to confirm the setting Note In the above setting or inquiry procedure if there is no button pressing within 10s remote controller will automatically exit th...

Страница 17: ...turning off the unit by pressing ON OFF button About AUTO RUN When AUTO RUN mode is selected the setting temperature will not be displayed on the LCD the unit will be in accordance with the room temp...

Страница 18: ...of battery box signal sender battery Cover of battery box remove reinstall NOTICE During operation point the remote control signal sender at the receiving window on indoor unit The distance between s...

Страница 19: ...on your smart phone tablet PC Method 2 Scan the QR code and download the application directly If your device is not compatible please download the application in other ways Method 3 Users of iOS syst...

Страница 20: ...Enter the WiFi setting of your phone and search for the wireless network named G xxxxxxxx Take G A0B40030 as an example Connect the network 4 Input the original password 12345 or 12345678 to connect...

Страница 21: ...to return and there will be a prompt box and then clock OK to finish the modification Meanwhile the software will turn back to interface of Air Conditioner and the AC list will be gone 18 6 Left slide...

Страница 22: ...ote controller and disconnect the power of AC Then re connect the power 1 minute later press WiFi and Mode buttons simultaneously If the AC gives out a beep sound it means the WiFi module is successfu...

Страница 23: ...he detailed operation 3 Fan Speed It used for setting fan speed Under cooling or heating mode if the noise customized function is turned on adjust the fan speed and then the noise customized function...

Страница 24: ...of remote controller for the function instruction Among that Purify Humidify Air exchange functions can be set through equipping with special air purifier humidifier E heater is not available for thi...

Страница 25: ...ed off through up down swing The up down swing in the Regional Swing is only valid under cooling and heating modes The left right swing area has relationship with the position of air conditioner set b...

Страница 26: ...mperature automatically Meanwhile the air conditioner will adjust frequency fan speed and set tempera ture automatically according to the load status for saving energy Noise The noise customized funct...

Страница 27: ...d maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do no...

Страница 28: ...the panel into a certain angle less than 60 do not open the panel too forcibly along the arrow direction from the two sides of panel the water below 45 to clean it and then put it in a shady and cool...

Страница 29: ...method 26 1 Check whether air inlets and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 4 Check whether mounting bracket for outdoor unit is damaged or corro...

Страница 30: ...Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceivin...

Страница 31: ...emperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper...

Страница 32: ...t again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or tu...

Страница 33: ...estarting the unit If not please It can be eliminated after restarting the unit If not please When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheat...

Страница 34: ...31 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall...

Страница 35: ...stallation location 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Univ...

Страница 36: ...placed by the manufacturer its 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance w...

Страница 37: ...should be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of 55 on the selected outlet pipe position In order to drain smoo...

Страница 38: ...ing out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear lef...

Страница 39: ...60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe N...

Страница 40: ...than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal with wire clip After finishing wiring of 18K unit clamp the grounding wire yellow green wire into the wire cro...

Страница 41: ...ately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indo...

Страница 42: ...nt charging vent 2 Connect the charging hose of piezometer to the refri gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump 3 Open the piezometer com pletely...

Страница 43: ...t grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It m...

Страница 44: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...

Страница 45: ...Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 12...

Страница 46: ...uitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port...

Страница 47: ...66160000152 Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com E mail info cooperandhunter com...

Страница 48: ...VIP INVERTER CH S09FTXHV B CH S12FTXHV B CH S18FTXHV B Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com RU...

Страница 49: ...Smart standby Smart standby 3 Smart Humidify Health 2...

Страница 50: ...1...

Страница 51: ...5 2...

Страница 52: ...3...

Страница 53: ...3 4 1 5 2 6 7 4...

Страница 54: ...3 17 4 6 14 12 11 8 7 10 9 2 1 5 CLOC X FAN HUMIDITY HEALTH SLEEP LIGH 1 7 8 I FEEL 4 3 2 5 6 11 13 12 16 10 14 15 AUTO COOL DRY FAN HEA 17 18 19 16 15 13 AIR 18 WI FI 19 COOL HEAT 5...

Страница 55: ...LIGHT SWING TEMP SLEEP SLEEP LIGHT T ON T OFF SAVE SE 8 C I feel Operation mode INTELLIGENT HOUR ON OFF WIFI Auto X FAN Turbo 6...

Страница 56: ...I FEEL 8 HEATING X FAN FAN SPEED X FAN FAN AUTO LOW MED HIGH I FEEL TEMP CLOCK HEAT 8 8 Humidity Health 7...

Страница 57: ...ON OFF MODE 1 4 3 2 AUTO COOL DRY FAN HEAT 2 AUTO 2 AUTO AUTO COOL DRY FAN HEAT AUTO I FEEL 8 I FEEL FAN 7 5 6 COOL HEAT low low medium medium medium high high super auto AUTO quiet Auto 8...

Страница 58: ...T ON T OFF 11 12 TIMER ON ON 1 TIMER ON TIMER ON TIMER OFF TIMER ON CLOCK 13 CLOCK 5 1 0 5 10 0 5 CLOCK 14 9 10 SWING OFF 15 Humidity Health AIR cancel INTELLIGENT cancel 9...

Страница 59: ...eep 1 1 2 Sleep 2 a 16 23 C 1 3 7 1 b 24 27 C 1 2 7 1 c 28 29 C 1 7 1 d 30 C 7 1 Sleep 3 Sleep 3 1 TURBO 1 hour 1 2 3 TURBO 4 2 hour 2 5 3 8 6 10 7 ON OFF MODE SLEEP Sleep 4 18 LIGHT 17 LIGHT X FAN CO...

Страница 60: ...MODE MODE 4 3 1 2 3 1 5 4 8 1 30 22 11...

Страница 61: ...Android iOS 4 1 G Life 2 QR 2 iOS G Life Apple s App Store Iphone 6 Android apk Apple s App Store 1 Android http cooperandhunter org download G Life_android_2 0 6_20141229 apk 12...

Страница 62: ...2 WiFi WiFi WiFi 3 WiFi G xxxxxxxx G A0B40030 4 12345 12345678 5 13...

Страница 63: ...8 WiFi 6 7 14 6 admin...

Страница 64: ...9 15 Wi Fi 1 Wi Fi 1 2 3 1 Wi Fi Wi Fi 2...

Страница 65: ...16 1 Mode 3 Fan Speed 2 Temperature...

Страница 66: ...17 1 Preset 2 Functions Turbo 3 Swing...

Страница 67: ...18 4 Advanced Regional Swing Regional Swing Air flow position Regional Swing Sleep curves...

Страница 68: ...19 Power saving Noise...

Страница 69: ...AUTO 25 AUTO AUTO 20 O T U A AUTO AUTO AUTO AUTO 20...

Страница 70: ...1 3 45 1 2 45 3 2 3 21...

Страница 71: ...22...

Страница 72: ...3 23...

Страница 73: ...30 8 24...

Страница 74: ...2 3 12 3 12 5 F1 F2 H1 25...

Страница 75: ...0 2 1 2 3 1 2 26...

Страница 76: ...18 54 30 24 2 80 27 32 23 54 26 27 24 18 DB WB C DB WB C...

Страница 77: ...1 2 3 4 5 6 7 8 28...

Страница 78: ...1 2 3 4 5 250 6 1 7 8 9 1 2 3 4 5 6 7 5 10 8 9 1 2 3 4 5 6 7 8 29...

Страница 79: ...16 A 25A 18 10 A 1 2 1 2 3 4 5 12 09 30...

Страница 80: ...15 15 15 300 250 50 30 200 30 50 31...

Страница 81: ...24 000 55 0 845 275 542 131 256 8 124 50 55 0 50 100 150 150 150 694 525 510 197 135 256 164 298 45 124 160 945 563 88 55 16 82 55 55 150 150 150 685 189 575 1018 315 157 158 65 45 36 65 90 65 150 150...

Страница 82: ...1 2 3 4 5 6 BL BB BR YE 33 N 2 3L BL BB N 2 3L BL BB BR YE BR YE N L...

Страница 83: ...6 9 52 12 15 20 30 40 45 55 16 60 65 19 70 75 1 2 1 2 1 2 34...

Страница 84: ...1 2 3 4 5 24 N 1 2 4 5 3 07 09 12 N 2 4 5 BL BB 18 N 1 2 4 5 VI OR BL BB VI OR BR BL BB VI OR BL BB BR VI OR 1 2 3 4 5 6 15 1 0 105 76cmHg 7 8 9 0 76cmHg Lo Hi 1 2 25 3 35...

Страница 85: ...1 1 2 3 4 2 1 ON OFF 2 COOL HEAT FAN 36...

Страница 86: ...a 1 2 3 c 37...

Страница 87: ...66160000152 Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com E mail info cooperandhunter com...

Отзывы: