background image

Split Air Conditioner

AIR-MASTER Series

OWNER’S MANUAL

Designed by Cooper&Hunter International Corporation, Oregon, USA

www.cooperandhunter.com

F

or proper operation

,

 please read and 

k

eep this manual carefully.

MODELS

:

 

 

                                                                  

 

CH-S07RX4

CH-S09RX4

CH-S12RX4

CH-S18RX4

CH-S24RX4

Содержание AIR-MASTER Series

Страница 1: ...ER Series OWNER S MANUAL Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com For proper operation please read and keep this manual carefully MODELS CH S07RX4 CH S09RX4 CH S12RX4 CH S18RX4 CH S24RX4 ...

Страница 2: ... where the product was purchased They can take this product for envi ronmental safe recycling R410A R32 125 50 50 1975 Content Operation Notices Precautions 1 Parts Name 6 Screen Operation Guide Buttons on remote controller 7 7 Introduction for buttons on remote controller 8 Function introduction for combination buttons 12 Operation guide 12 Replacement of batteries in remote controller 12 Emergen...

Страница 3: ... appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric...

Страница 4: ...damage 2 Precautions Warning conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause obje...

Страница 5: ...cables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity plea...

Страница 6: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions Warning wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refri...

Страница 7: ...l injury or damage If you need to relocate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range Indoor side DB WB Outdoor side DB WB Maximum cooling 32 23 43 26 Maximum heating 27 24 18 The operating te...

Страница 8: ... Outdoor Unit air inlet panel aux button horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display remote controller Notice Actual product may be different from above graphics please refer to actual products air inlet air outlet Connection wire ...

Страница 9: ...perature turbo mode set time T I M E R O N T I M E R OFF child lock light up down swing Temp display type set temp outdoor ambient temp indoor ambient temp 1 3 4 6 8 10 12 2 5 7 9 11 1 ON OFF button 2 MODE button 3 button 4 FAN button 5 button 6 CLOCK button 7 TIMER ON TIMER OFF button 8 X F Note X FAN is the same with BLOW AN button 9 TEMP button 10 TURBO button 11 LIGHT button 12 SLEEP button ...

Страница 10: ...e Cool indicator on indoor unit is ON Press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting dry mode the air conditioner operates at low speed under dry mode Dry indicator on indoor unit is ON Under dry mode fan speed can t be adjusted Press button to adjust fan blowing angle When selecting fan mode the air conditione...

Страница 11: ... as auto AUTO low medium high 4 Auto Note g n i d r o c c a y l l a c i t a m o t u a d e e p s n a f r e p o r p t c e l e s l l i w r e n o i t i d n o c r i a d e e p s O T U A r e d n U to ex factory setting Fan speed under dry mode is low speed Pressing this button can select up down swing angle Fan blow angle can be selected circularly as below button 5 horizontal louvers stops at current po...

Страница 12: ...TIMER ON button to cancel it TIMER OFF button TIMER OFF button can set the time for timer off After pressing this button icon disappears and the word OFF on remote controller blinks Press or button to adjust TIMER OFF setting After each pressing or button TIMER OFF setting will increase or decrease 1min Hold or button 2s later the time will change OFF will stop blinking icon resumes displaying Can...

Страница 13: ...mbient temperature Note Outdoor temperature display is not available for some models At that time indoor unit receives signal while it displays indoor set temperature It s defaulted to display set temperature when turning on the unit There is no display in the remote controller Only for the models whose indoor unit has dual 8 display When selecting displaying of indoor or outdoor ambient temperatu...

Страница 14: ...ow medium and high speed 5 Press button to select fan blowing angle Replacement of batteries in remote controller 1 Press the back side of remote controller marked with of battery box along the arrow direction 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery reinstall remove Cover of battery ...

Страница 15: ... on it will operate under auto mode aux button panel Clean and Maintenance Note Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recomme...

Страница 16: ...en the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly Note The filter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to ...

Страница 17: ...rroded If yes please contact dealer 5 Check whether drainage pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air con...

Страница 18: ...room Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it ag...

Страница 19: ...or temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatur...

Страница 20: ... unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of...

Страница 21: ...e Above indicator diagram is only for reference Please refer to actual product for the actual indicator and position When below phenomenon occurs please turn off air conditioner and discon for service Power cord is overheating or damaged There s abnormal sound during operation Air switch trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner oper...

Страница 22: ...least 30cm At least 300cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction At least 30cm At least 15cm At least 15cm Space to the wall Space to the wall Space to the wall At least 200cm At least 50cm ...

Страница 23: ...h high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances 7 The appliance shall not be install ed in the laundry will not affect neighborhood 2 The location should be well ventilated and dry in which the outdoor unit Tools for installation 1 Level...

Страница 24: ...t will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations 1 The air conditioner is the first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The y...

Страница 25: ...ly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of Φ55 on the selected outlet pipe positi...

Страница 26: ...nch 2 When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit union nut pipe joint pipe Indoor 5 10 outdoor Φ55 Note Pay attention to dust prevention and ta...

Страница 27: ...w on the wiring cover and then take wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Installation of indoor unit torque wrench open end wrench indoor pipe pipe union nut Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 40 55 60 65 70 75 15 20 indoor unit 2 Bind the joint ...

Страница 28: ...For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip power connection wire cable cross hole 2 Make...

Страница 29: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with seal...

Страница 30: ...at least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step two install drain joint Only for cooling and heating unit 1 Connect the outdoor drain joint...

Страница 31: ... union nut with torque wrench by referring to the sheet below handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 40 55 60 65 70 75 15 20 N 1 2 4 5 blue black violet orange ye low green Indoor unit connection 07 09 12K Heat pump type 1 Remove the wire clip connect the po wer connection wire and signal ...

Страница 32: ...e slightly dow nwards The drain hose can t be curved raised and fluctuant etc The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain hose the drain hose can t raise upwards The drain hose can t be fluctuant The drain hose can t be fluctuant The water outlet can t be fluctuant The water outlet can t be placed in water Note 2 Fix t...

Страница 33: ...If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent Use vacuum pump liquid valve gas valve refrigerant charging vent nut of refrigerant charging vent vacuum pump piezometer valve cap Lo Hi inner hexagon spanner open close 1 With...

Страница 34: ... unit grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connect...

Страница 35: ...d length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu ...

Страница 36: ...eter of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ9 52 or Φ12 Φ12 Φ16 Φ19 Φ22 2 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe ...

Страница 37: ... suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand th...

Страница 38: ...Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com E mail info cooperandhunter com 66129915261 ...

Отзывы: