Страница 1: ...1 IceProbe Thermoelectric Aquarium Chiller Model IPAC 50W Instructions Warranty For U S A Only ...

Страница 2: ...rfaces 6 Do not use device for other than intended use 7 Provide four to six inches of air space around the fan and heat sink for air circulation 8 Do not plug the IceProbe directly into a 120VAC power source i e standard wall outlet This device is intended to operate at 12VDC and draws approximately 5 amps 9 Only power the IceProbe with the power supply included with the device 10 Do not attempt ...

Страница 3: ...ead this entire manual carefully Assess the area where you intend to bulkhead the IceProbe before drilling any holes It is important to ensure there is adequate clearance for the probe and ample space for air circulation around the fins and fan In larger aquariums 20 to 55 gallons two or more Aquarium Chillers may be needed to achieve the desired temperature differential If you intend to install m...

Страница 4: ... through the hole with the clear silicon washer on the outside dry side of the reservoir wall 4 Tighten the nylon nut on the threaded probe While a watertight seal can often be achieved by hand tightening the nut we recommend using an adjustable wrench However be careful not to over tighten the nut by applying excessive force The IceProbe can be oriented in any way Provided that the probe is fully...

Страница 5: ...lightly cooler than the liquid around it To achieve the maximum temperature pull down the unit must run continuously for several days Optional Temperature Controller The chiller cools continuously when powered In most aquarium implementations the CoolWorks Proportional Temperature Controller is added to regulate the IceProbe s cooling power Temperature Controller IceProbe CoolWorks offers two Prop...

Страница 6: ... when used in conjunction with CoolWorks temperature controllers Compressed air a small vacuum cleaner attachment or a small soft brush can be used to remove dust and lint from the fan and thereby extending its useful life If the fan motor is not running at all or very slowly contact CoolWorks Customer Service Probe Coating The solid aluminum probe which contacts the water is coated with a very du...

Страница 7: ...l fuse has opened ON ON Thermoelectric cooling module failure Please contact a qualified electrician if the cause of the problem is related to your electrical outlet Replacement power supplies can be purchased from CoolWorks Resellers or CoolWorks Customer Service and can be easily installed Fan motor safety thermal fuse and thermoelectric cooling module repairs must be performed by the CoolWorks ...

Страница 8: ... incurred through negligence in use faulty packing or mishandling in transit by any common carrier Your remedy does not include loss of aquatic life cost of inconvenience or damage due to product failure In no event shall CoolWorks Inc be liable for incidental or consequential damages This warranty gives you specific legal rights you may also have other rights which vary from state to state Servic...

Отзывы: