Operating Manual

A30 BUS

A/C Service-Unit for refrigerant R134a

Doc.No.: 22102-V20177rev03.b

Содержание A30 BUS

Страница 1: ...Original Operating Manual Operating Manual A30 BUS A C Service Unit for refrigerant R134a Doc No 22102 V20177rev03 b...

Страница 2: ...and safety instructions All company names and product names are trademarks of their respective owners All rights reserved If you have any questions please contact the respective service partner of you...

Страница 3: ...the components 10 3 2 Machine description 10 3 3 Machine handling 12 3 4 On Off and stopping 12 4 Preparation for the use and settings 12 4 1 Switch on the machine 12 Switch on the machine for the fir...

Страница 4: ...eport 32 6 7 Scale reset 32 6 7 1 Refrigerant Weight scale 32 6 7 2 Waste oil Weight scale 33 7 Technical features 34 8 Disposal 35 8 1 Storage for long periods 35 8 2 Disposal of used fluids 35 8 3 D...

Страница 5: ...t prior notification The purpose of this operating manual is To supply the user with all the information needed to use the unit starting from purchase on through to the disposal of this same machine T...

Страница 6: ...fication and information about refrigerant The refrigerant is classified in Table E 1 Refrigerants designation of Annex E Normative of the European standard EN 378 1 2008 A1 2010 E EN 378 1 2011 The r...

Страница 7: ...ine relative to this operating manual Refrigerant Fluid reported on the identification label A C system Air conditioning system in the vehicle External container New Refrigerant used to fill the inter...

Страница 8: ...ch on the machine unless the machine is going to be used immediately Cut off the electrical power supply prior to long intervals in which the machine will not be used Attention Ensure that all valves...

Страница 9: ...ation DO NOT MODIFY THE SAFETY DEVICES 2 5 Not condensable gas discharge A not condensable gas discharge valve is installed to allow these gasses to be released The not condensable gas discharge valve...

Страница 10: ...and ensure that the following parts are present EC PED documentation 3 2 Machine description Control panel 1 Display 2 START button LED 3 STOP button LED 4 Information button i 5 Cancel button X 6 CO...

Страница 11: ...h 10 Internal vessel pressure gauge 11 Storage box for accesso ries 12 Container for absorbed oil 500 ml 13 Container for UV leakage additive 250 ml 14 Container for new oil 500 ml 15 LP quick couplin...

Страница 12: ...4 1 Switch on the machine Press the Power Switch I to turn on the Machine The ventilation security system starts Switch on the machine for the first time Select the display language Turn COOLIUS SELEC...

Страница 13: ...dure and start up the machine in DEMO MODE NOTE STOP key is available only if there is at least one day left for DEMO MODE otherwise the activation is compulsory and only the START key is available Un...

Страница 14: ...n tenance work Paper width W 58 mm Diameter D 40 mm Paper feed 1 Before a process Turn COOLIUS SELECT to select the character then confirm by ENTER Max 20 characters plate chassis etc At the end of a...

Страница 15: ...mbol shows the current position of the cursor The number of symbols shows the number of available menu points of this level Overview of the menu contents 1 OTHER SELECTIONS SERVICE A C PRESSURE TEST A...

Страница 16: ...confirm The next menu item is displayed Leak test The default value is applied in A C DATABASE and FULL SERVICE Turn COOLIUS SELECT to set Press ENTER to confirm The next menu item is displayed Fresh...

Страница 17: ...lius ac com or by phone call to the hotline 497940981888188 1 Printer built in 0 Printer off line or not installed Turn COOLIUS SELECT to select 1 or 0 Press ENTER to confirm then press STOP key to ex...

Страница 18: ...g The display shows the following line Press STOP when the 5 lines are set 4 5 Maintenance messages At the start up is possible to see the following messages Notice MAINTENANCE WILL EXPIRE SOON or MAI...

Страница 19: ...RT to by pass the process and go to charge process Insufficient refrigerant Charge the vessel The refrigerant quantity is below the minimum quantity required Perform Vessel charge WARNING Empty waste...

Страница 20: ...than the minimum value for the process Replace the external bottle then press START key to confirm Press STOP key to complete the process Process completed 6 Close the tank valve and disconnect the r...

Страница 21: ...ELECT to select OTHER SELECTIONS 2 Press ENTER to confirm 3 Turn COOLIUS SELECT to select NEW OIL BOTTLE CHANGE 4 Press ENTER to select 5 Replace the oil bottle with the new oil bottle 250 ml oil bott...

Страница 22: ...e not closed Message 9 Press START key to confirm The machine starts The process cleans the complete unit included the service hoses At the end 10 Press STOP key at the end The machine is ready Join H...

Страница 23: ...printer p 14 8 Press START key to confirm The equipment performs all the processes Recovery residual refrigerant check used oil drain process Vacuum Leak test New oil charge UV Dye charge Refrigerant...

Страница 24: ...The memory contains the data of the main cars on the market 1 Press ENTER to select 2 Press ENTER to confirm 3 Turn COOLIUS SELECT to select the brand 4 Press ENTER to confirm 5 Turn COOLIUS SELECT to...

Страница 25: ...by mode 2 Press ENTER to confirm 3 Turn COOLIUS SELECT to select the program or more programs The following selections are available RECOVERY VACUUM A C SYSTEM CHARGE RECOVERY VACUUM VACUUM A C SYSTE...

Страница 26: ...NTER to confirm 3 Turn COOLIUS SELECT to set the refrigerant amount Minimum 50 g 4 Press ENTER to confirm B In case of vacuum not selected C In case of A C system charge 5 Turn COOLIUS SELECT to set u...

Страница 27: ...IUS SELECT enter the UNLOCK CODE 3 Once done confirm by START In order to clean the vehicle A C system the equipment performs a washing process in single or Multi pass multiple flushes For more detail...

Страница 28: ...ance can be made exclusively by SERVICE CENTER authorized by the manufacturer 1 Press ENTER to go to selection menu if in Stand by mode 2 Turn COOLIUS SELECT to select OTHER SELECTIONS and confirm by...

Страница 29: ...efore reset Note Only genuine spare parts or their equivalent The use of replacement parts which are not of equivalent quality may damage the machine Go to website www coolius ac com or call the hotli...

Страница 30: ...the purpose to reduce the internal pressure before dismount the filter start a recovery process Attention Risk of injury from electric shock Before working on the machine always disconnect the plug f...

Страница 31: ...wer supply Note Disposal in according to local directives 1 Open the front cover 3 screws 2 Unscrew the oil discharge screw and wait for the oil to drain Refit discharge screw 3 Unscrew the muffler 4...

Страница 32: ...ate the scale deviation perform the following instructions 1 Turn COOLIUS SELECT to select OTHER SELECTIONS confirm by ENTER 2 Turn COOLIUS SELECT to select SCALE RESET 3 Press ENTER to confirm 4 Turn...

Страница 33: ...tructions 6 7 2 Waste oil Weight scale 1 Disconnect the waste oil bottle from its coupler 2 Press START key to confirm bottle disconnected Warning Confirm by START only if the waste oil bottle is disc...

Страница 34: ...1000 ml Refrigerant Weight scale 200 kg Scale accuracy 2 g Vacuum pump 170 lt min Final pressure McLeod abs 0 05 mb Electronic vacuum meter YES Oil charge Automatic Bottle capacity Oil charge 500 ml...

Страница 35: ...or to disposal The lubricants extracted from A C system must be delivered to used oil collection centre 8 3 Disposial of packaging material The cardboard packaging material should be disposed of with...

Страница 36: ...addition you will find further help and instructions for your COOLIUS device on this website Manufactured by WOW ITALY Viale della Stazione 7 39100 Bolzano Italy Tel 39 0546 060461 AUTOCOM Diagnostic...