Cooledge FABRICOLOR Скачать руководство пользователя страница 1

EXT-0091-R00-02262020 (LTR) 1/22

Cooledge 

FABRIColor 

is a simple, out-of-the-box 

way to incorporate the unique look and feel of a 
stretch fabric ceiling into your space. Create a canopy 
of light in T-bar grid ceilings by adding skylights to 
provide immersive illumination that delivers the 
visual, biological, and emotional benefits of large 
luminous surfaces.

Grid (T-Bar) luminaires deliver immersive illumination for:
• 

Offices

• 

Healthcare facilities

• 

Meeting rooms

• 

Educational buildings

Features Cooledge’s unique “Infinity Edge” design 

for uniform illumination from edge to edge.

1. COMPONENTS

Suspension Cable

Cable Gripper
Hanger Bracket

Control Module

Power and Control Tray

Power Supply

Trim Clip

Trim

Corner

Trim

O  +1 604 273 2665  

F   +1 604 273 2660  

T   +1 844 455 4448  

W  cooledgelighting.com

Cooledge Lighting Inc. 

110-13551 Commerce Parkway  

Richmond, BC  V6V 2L1 Canada

Cooledge Lighting reserves the right to change 

materials or modify the design of its product 

without notification as part of the company’s 

continuing product improvement program.

COOLEDGE LUMINOUS CEILINGS

FABRICOLOR - GRID (T-BAR)

INSTALLATION GUIDE

5 Year Limited Warranty: 

Parts and workmanship 

5

5 Y

EA

R S

YSTEM WAR

RA

N

TY

YE

AR

 SY

STEM WARR

AN

TY

Содержание FABRICOLOR

Страница 1: ... Infinity Edge design for uniform illumination from edge to edge 1 COMPONENTS Suspension Cable Cable Gripper Hanger Bracket Control Module Power and Control Tray Power Supply Trim Clip Trim Corner Trim O 1 604 273 2665 F 1 604 273 2660 T 1 844 455 4448 W cooledgelighting com Cooledge Lighting Inc 110 13551 Commerce Parkway Richmond BC V6V 2L1 Canada Cooledge Lighting reserves the right to change m...

Страница 2: ...ing Cooledge FABRIColor Do not remove the plastic protective film until the point noted in this install guide CAUTION Use appropriate Personal Protective Equipment PPE to ensure safety at work Measuring Tape Level 2 Phillips Screwdriver 3mm Flat Head Screwdriver 2x wrenches only required for threaded rod mounting Saw Horses 4mm and 5mm Hex Key Gloves Cable Cutters ...

Страница 3: ...am tees If this is required to make the correct opening size for the luminaire consult a ceiling contractor 3 INSTALLATION PROCEDURE NOTE Lift luminaire using handles provided NOTE Power Supply and Control Module may vary NOTE Trays may be mounted remotely In this case the DC power connections should be made to the Luminaire section 3 4 with a suitable length of cable Refer to Section 8 APPENDIX D...

Страница 4: ...o power supply ToControls Starte DoNot Connect DO NOT CONNECT DO NOT CONNECT DO NOT CONNECT DO NOT CONNECT NOTE The power and control tray type will vary depending on region and luminaire size 3 4 CONNECT POWER AND CONTROL TRAY TO LUMINAIRE NOTE Lift luminaire using handles provided 3 5 ESTABLISH THE REQUIRED POSITIONS FOR SUSPENSION CABLES Either measure between the suspension points or refer to ...

Страница 5: ...EXT 0091 R00 02262020 LTR 5 22 3 6 ATTACH CABLES TO CEILING ANCHOR POINTS AT REQUIRED POSITIONS 3 7 ATTACH CABLES TO HANGER BRACKETS WITH GRIPPERS ...

Страница 6: ...nnections should be made by a qualified electrician in accordance with all national and local electrical and construction codes Refer to Section 8 APPENDIX DMX CONTROL for setting up the control module Leave space for electrician to make connection to power supply Connect AC to Power Supply NOTE Power Supply and Control Module may vary ...

Страница 7: ...RIM WITH PROVIDED CLIPS 3 10 REMOVE THE PROTECTIVE PLASTIC WRAPPING AND LIFTING HANDLES Remove the lifting handles using a 4mm Hex Key Ensure you wear gloves from this point forward to prevent marks on the fabric 3 12 ATTACH CORNER COVER TO TRIM ...

Страница 8: ...rippers through adjacent ceiling grid opening and lift the luminaire until the trim is flush with the underside of the ceiling grid WARNING Overtightening the cables may lift the ceiling grid and cause damage to the luminaire CEILING TILE CEILING GRID TRIM PIECE FLUSH WITH UNDERSIDE OF GRID ...

Страница 9: ...g Brush gently with a clean micro fiber cloth or magic eraser if available in your region Vacuum with a clean brush tip vacuum nozzle Blow with compressed air ensure there is no oil or grease Use an adhesive lint roller recommended to test a small area in case the specific type of roller leaves a residue For minor stains spots or streaks Cooledge recommends gently wiping the fabric with isopropyl ...

Страница 10: ...ENDIX POSITIONS OF SUSPENSION POINTS y y x x C L C L C L C L TABLE 1 NOMINAL SIZE SUSPENSION POINTS DIM X DIM Y 4 X 4 4 20 5 8 22 1 8 4 X 6 4 21 5 8 22 1 8 4 X 8 4 26 5 8 22 1 8 1200mm X 1200mm 4 525mm 550mm 1200mm X 1800mm 4 550mm 550mm 1200mm X 2400mm 4 655mm 550mm ...

Страница 11: ...ls Status LED Power Input Mode and Addressing DIP Switch DMX Inputs DMX To access the DIP switches for selecting the operational mode unfasten the cover screw and rotate cover out of the way Positions 1 3 are used to identify the controller mode Settings for each mode are explained in each section Switches 1 3 Control Module MODE Black Red N C Green N C Blue N C White 8 APPENDIX DMX CONTROL ...

Страница 12: ...cted The address is selected by the sum of the values of each ON switch Addresses 1 through 511 are possible In standard mode there are Red Green Blue and White channels Each can handle up to a 90W load Switch 4 5 6 7 8 9 10 11 12 Address 256 128 64 32 16 8 4 2 1 SELECTING DMX ADDRESSES SELECTING DMX ADDRESSES Switches 1 3 Factory set refer to modes below for details Switches 4 12 Addressing switc...

Страница 13: ... occupies 8 x DMX channels assigned as below DMX CH1 DIM Coarse RED Channel DMX CH2 DIM Fine RED Channel DMX CH3 DIM Coarse GREEN Channel DMX CH4 DIM Fine GREEN Channel DMX CH5 DIM Coarse BLUE Channel DMX CH6 DIM Fine BLUE Channel DMX CH7 DIM Coarse WHITE Channel DMX CH8 DIM Fine WHITE Channel Example of addressing units for 16 bit LIN LOG Modes on DMX bus 1 Unit 1 takes DMX Address 1 and unit occ...

Страница 14: ...5 and unit occupies DMX Channels 5 8 3 Unit 3 takes DMX Address 9 and unit occupies DMX Channels 9 12 For the above the DIP SETTINGS are 1 000 000000001 Controller set for 8 bit LIN LOG Mode unit occupies DMX Channels 1 4 2 000 000000101 Controller set for 8 bit LIN LOG Mode unit occupies DMX Channels 5 8 3 000 000001001 Controller set for 8 bit LIN LOG Mode unit occupies DMX Channels 9 12 For 16 ...

Страница 15: ... Standard Modes the dimming curves are shown below 8 bit LOG DIMMING CURVE DMX INPUT DUTY CYCLE OUTPUT 0 20 40 60 80 100 120 140 100 80 60 40 20 0 8 bit LIN DIMMING CURVE DMX INPUT DUTY CYCLE OUTPUT 0 20 40 60 80 100 120 140 100 80 60 40 20 0 ...

Страница 16: ...hannel fixed LOG for 16bit 8bit FIXED RED LIN 1 0 0 X X X X X X X 0 1 RED channel fixed LIN for 16bit 8bit FIXED GREEN LOG 1 0 0 X X X X X X X 1 0 GREEN channel fixed LOG for 16bit 8bit FIXED GREEN LIN 1 0 0 X X X X X X X 1 1 GREEN channel fixed LIN for 16bit 8bit FIXED BLUE LOG 1 0 1 X X X X X X X 0 0 BLUE channel fixed LOG for 16bit 8bit FIXED BLUE LIN 1 0 1 X X X X X X X 0 1 BLUE channel fixed ...

Страница 17: ...L 0 1 0 0 0 10 LIGHT CORAL 0 1 0 0 1 11 YELLOW 0 1 0 1 0 12 LIGHT VIOLET 0 1 0 1 1 13 OLIVE 0 1 1 0 0 14 AQUAMARINE 0 1 1 0 1 15 SPRING GREEN 0 1 1 1 0 16 LIGHT SEA GREEN 0 1 1 1 1 17 LIME GREEN 1 0 0 0 0 18 PALE GREEN 1 0 0 0 1 19 TURQUOISE 1 0 0 1 0 20 ROYAL BLUE 1 0 0 1 1 21 SKY BLUE 1 0 1 0 0 22 CYAN 1 0 1 0 1 23 POWDER BLUE 1 0 1 1 0 24 SLATE BLUE 1 0 1 1 1 25 LAVENDER 1 1 0 0 0 26 AZURE 1 1 ...

Страница 18: ...N BLUE or WHITE Fixed Modes the dimming curves are shown below STANDALONE FIXED RGBW LIN DIM CURVE OUTPUT DMX INPUT 0 20 40 60 80 100 120 140 100 80 60 40 20 0 STANDALONE FIXED RGBW LOG DIM CURVE OUTPUT DMX INPUT 0 20 40 60 80 100 120 140 100 80 60 40 20 0 ...

Страница 19: ...1 2 87 61 0111100 3 01 62 0111101 3 16 63 0111110 3 32 64 0111111 3 48 65 1000000 3 67 66 1000001 3 85 67 1000010 4 04 68 1000011 4 24 69 1000100 4 47 70 1000101 4 71 71 1000110 4 95 72 1000111 5 2 73 1001000 5 47 74 1001001 5 76 75 1001010 6 07 76 1001011 6 39 77 1001100 6 73 78 1001101 7 1 79 1001110 7 47 80 1001111 7 87 81 1010000 8 3 82 1010001 8 75 83 1010010 9 21 84 1010011 9 71 85 1010100 1...

Страница 20: ...1 46 83 61 0111100 47 63 62 0111101 48 4 63 0111110 49 19 64 0111111 49 97 65 1000000 50 77 66 1000001 51 55 67 1000010 52 34 68 1000011 53 12 69 1000100 53 92 70 1000101 54 7 71 1000110 55 49 72 1000111 56 27 73 1001000 57 07 74 1001001 57 85 75 1001010 58 65 76 1001011 59 42 77 1001100 60 21 78 1001101 61 79 1001110 61 8 80 1001111 62 58 81 1010000 63 38 82 1010001 64 15 83 1010010 64 95 84 1010...

Страница 21: ...down to 0 for 1s starting with RED GREEN BLUE WHITE and then repeats indefinitely with a period of 8 seconds DYNAMIC MIXED COLOR Each color output duty cycle starts from 0 and ramps linearly up to 100 output for 2s then ramps back down to 0 for 2s Channels start ramping with 1s delay starting with RED color and repeats indefinitely STANDALONE DYNAMIC RGBW 8bits 16bits MODE Pos 1 3 Switches 4 12 DY...

Страница 22: ...horted one are flashing The rest of units in the installation remain responsive to DMX commands Output short circuit between any two R G B W All RED LED flashes at 1s rate Color shorted is brighter still DMX control Output Overload RED LED flashes at 1s rate Loads Flash at 1s rate DMX Disconnected during normal operation D or D from unit n Standard Amber LED on units with addresses n Units with ad...

Отзывы: