P2M053STD-Ver1.1
12
GB
Troubleshooting
Fault
Potential Failure
Problem solving action
E1
Short or broken circuit of the low
temperature sensor.
Please contact the after sales ser- vices to
change the sensor.
F4
Short or broken circuit of the sensor in the
upper compartment.
F5
Short or broken circuit of the sensor in the
lower compartment.
H1
The appliance gives a high-temperature
warning when the upper compartment’s
temperature has been higher than 25 °C
for 3 hours.
Ambient temperature is too high. The appliance
working temperature should be between 16 °C
and 38 °C.
H2
The appliance gives a high-temperature
warning when the lower compartment’s
temperature has been higher than 25 °C
for 3 hours.
L1
The compressor stops working when the
tem- perature of the upper compartment
is lower than 0 °C. The low-temperature
warning is given when the temperature
has been lower than 0 °C for 2 hours.
Ambient temperature is too low. The appliance
working temperature should be between 16 °C
and 38 °C.
L2
The compressor stops working when the
tem- perature of the lower compartment
is lower than 0 °C. The low-temperature
warning is given when the temperature
has been lower than 0 °C for 2 hours.
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and/ or lead are damaged
Call your agent or qualified technician
Fuse in the plug has blown
Replace the fuse (UK Plug)
Power supply
Check power supply
The appliance turns
on, but the
temperature
is too high/ low
The temperature is set too high.
Reset the temperature.
Bottles have been added recently.
Allow time for recently added bottles to reach
desired temper- ature.
Doors are not shut properly
Check doors are shut and seals are not
damaged
Appliance is located near a heat
source or air flow to the condenser is
being interrupted
Move the refrigerator to a more suitable
location
Ambient temperature is too high
Increase ventilation or move appliance to
a cooler position
Unsuitable foodstuffs are being
stored in the appliance
Remove any excessive hot foodstuffs or
blockages to the fan
Appliance is overloaded
Reduce the amount of bottles stored in
the appliance
The appliance is
unusually loud
Loose nut/ screw
Check and tighten all nuts and screws
The appliance has not been installed
in a level or stable position
Check installation position and change if
necessary
The appliance is
leaking water
The appliance is not properly leveled
Adjust the screw feet to level the
appliance (if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is
obstructed
Clear the floor of the appliance (if
applicable)
The water container is damaged
Call your agent or qualified Technician
The drip tray is overflowing
Empty the drip tray (if applicable)
Содержание CW 90