INSTALLATION, OPERATION & MAINTENANCE MANUAL 

 

Eco

Syn

 80 / 100 

 

 

                            

 

Содержание EcoSyn 100

Страница 1: ...1 INSTALLATION OPERATION MAINTENANCE MANUAL EcoSyn 80 100 ...

Страница 2: ...re than 0 1 MPa 1 bar Water may drip from the outlet opening of the safety valve so the outlet opening should be set to atmospheric pressure The outlet of the safety valve should be installed facing downwards and in a non freezing area To ensure proper functioning of the safety valve the user should perform regular controls to remove limescale and make sure the safety valve is not blocked Do not i...

Страница 3: ... product was purchased INTRODUCTION Dear Customer Thank you for purchasing this product This heat pump for heating sanitary water is one of the most advanced appliances in its class Its material design and testing were made in compliance with related applicable standards Power capacity and safety systems were thoroughly tested Tests were made individually for each component part as well as for the...

Страница 4: ...before servicing The heat pump may not be used for purposes other than those defined in these Instructions The unit is not designed for industrial use or use in rooms where corrosive or explosive substances are present The manufacturer shall not assume any liability for damages caused by incorrect installation or misuse that are not in compliance with the Instructions for installation and use The ...

Страница 5: ...at from a low temperature level e g heat from the ambient air to a higher temperature level e g hot sanitary water The heat drawn from the ambient air along with the electric energy generates heating energy which is available for heating the sanitary water Fig 1 Chart of energy flow through the heat pump unit DIMENSIONS normal DIN normal NF Fig 2 Connection and installation dimensions of the heat ...

Страница 6: ... is placed on the bottom left side in the form of a plastic tube with an external diameter of ø18 mm This tube should be connected to the external condensate outlet pipe and led to the sewage system or a container The quantity of condensate depends on air temperature and humidity when the heat pump is in operation To prevent pressure depression in the building fresh air must be regularly supplied ...

Страница 7: ...ng air from other premises In this type of operation the heat pump uses air from other premises via a pipeline system It is advisable to insulate the pipeline system to prevent the formation of condensate In case of using air from outside the external part must be covered so as to prevent the intrusion of dust or snow into the appliance Besides the drag in the pipes and elbows the user should be a...

Страница 8: ... the fan The diagram Diagram 1 includes aerodynamic characteristics of the operation of the fan The top line represents the curve of air flow depending on the pressure drop at maximum speed of the fan 100 The bottom line represents the operation of the fan at minimum speed 40 The curves between 60 80 represent the aerodynamic characteristics at lowered revolutions of the fan The bottom line that l...

Страница 9: ...m 1 Aerodynamic characteristics Air inlet and outlet pipeline system When connecting the sanitary heat pump to an existing pipeline system we use the basic pipe elements that we connect into a pipeline system for air inlet and outlet The air pipeline should consist of round pipes with an inner diameter of ø125 mm or rectangular pipes with a cross section of 150x70 mm Fig 6 Schematic demonstration ...

Страница 10: ...n in Table 1 Type of element Value of static pressure loss a Spiral ribbed pipe Diagram 2 b Rectangular pipe 150x70 mm Diagram 2 according to DN 125 c Rectangular elbow horizontal 90 5 Pa d Elbow 90 4 Pa e Angular reducer ø125 to 150x70 5 Pa f Rectangular elbow vertical 90 5 Pa g Elbow 45 3 Pa h Reducer ø125 to 150x70 3 Pa i Flexible tube Diagram 2 j Air intake grid 25 Pa Table 1 Types of elements...

Страница 11: ...m 1 there are two zones of operation of the sanitary heat pump among the curves The dark zone represents the area of use with higher efficiency The volumetric air flow is higher in this zone which requires a lower pressure drop channel system version with minimum pressure drop The light zone represents the area of use with lower air flow in relation to the pressure drop and fan setting Noise Like ...

Страница 12: ...o the point where the lines cross Example of selecting the aerodynamic characteristic In diagram 3 at air flow of 150 m h draw a vertical line The pipeline represents 70 Pa of pressure drop which is added to the below red line Total pressure drop is thus 90 Pa Draw a horizontal line at the pressure drop of 90 Pa The point where the lines meet lies on the curve that corresponds to 60 speed of the f...

Страница 13: ...ng on the type of the valve and open the drain from the safety valve Water must flow from the valve nozzle showing that the valve operation is faultless During the heating of water the water pressure in the hot water tank is increased up to the level preset in the safety valve Since the system prevents backflow of water into the water supply mains water may be dripping from the outlet opening on t...

Страница 14: ...r supply network must take place in accordance with the standards for electric appliances To comply with the national installation regulations an all poles disconnect switch must be installed between the heat pump and the power supply network Fig 8 Protective cover Fig 9 Electrical circuit diagram Legend T1 Bar with sensors T2 Evaporator temp sensor T3 Air temperature sensor 1 4 way valve 2 Compre...

Страница 15: ...source of heating turned on 3 Signalization of the backup operation 4 Indication overview of operation errors entrance into the service menu 5 Display and setup of temperature in C 6 Start and setup of the VACATION programme 7 Day of the week 1 Monday 7 Sunday 8 Reducing the value 9 Heat pump on off switch 10 Increasing the value 11 TIMER start and setup 12 Time setup and display 13 Start up of qu...

Страница 16: ... lower temperatures When the appliance is switched on the fan starts first and operates for one minute symbol no 20 is displayed If the temperature of inlet air is lower than 7 C the fan is turned off Domestic water is heated with heaters The heat pump operates in the reserve mode symbol no 14 is displayed The possibility of switching to normal mode is checked every 2 hours by switching on the fan...

Страница 17: ...ting The setting is stored when you press field no 12 or when the field stops flashing Setting the temperature Press field no 5 the set temperature starts blinking By pressing or you can change the temperature setting from 10 C to 75 C preset to economic temperature of 55 C The setting is stored by pressing field no 5 again or when field no 5 stops flashing After a few seconds the display shows th...

Страница 18: ... no 11 for a while fields 7 and 11 start to flash By pressing fields or choose among three timer modes of operation Timer mode of operation of the heat pump for the entire week numbers 1 7 flash in field no 7 Timer mode of operation of the heat pump for Monday to Friday and Saturday to Sunday numbers 1 5 and then 6 and 7 flash in field no 7 Timer mode of operation of the heat pump for each day at ...

Страница 19: ... filed 2 again the ventilation is deactivated By shutting down the heat pump with the on off options the ventilation is deactivated In case of power failure while the ventilation is activated the ventilation will proceed after the reconnection of the power supply for the remaining time but no longer than 30 minutes In the event of any other failure the ventilation is deactivated Ventilation cannot...

Страница 20: ...ld on the left is intended for its value The first parameter 00 is a version of a software code and serves information purposes only By pressing the right number Field CLOCK in Figure 12 you proceed to the next parameter Installation level code 1166 After the first code entry for the installation level the programme allows access to the following parameters 00 programme code 21 fan speed 27 low te...

Страница 21: ...ive Factory settings of the anti legionella function activation Every 14 days of the heat pump operation if the water temperature in the previous 2 week period did not exceed 65 C continuously for at least an hour The anti legionella function works only when the heat pump is switched on When activated symbol no 17 is displayed The anti legionella function can be activated manually by pressing fiel...

Страница 22: ...y the heat pump will last for years without service The exterior of the heat pump should be cleaned with a mild detergent solution Do not use solvents or abrasive cleaning agents If the heat pump was exposed to dust evaporator lamellas might become blocked which can have a detrimental effect on the functioning of the heat pump In this case the evaporator should be cleaned The cleaning of the evapo...

Страница 23: ...e service E005 Overheating temperature 85 C electronic regulator failure Unplug the heat pump from the power supply Call the service E006 Mg anode error Call the service heat pump functions normally E007 Volume and or temperature sensors error Call the service E042 Anti legionella function error Press field no 4 to restart E247 Defrosting error Automatically turns on heating with the electric heat...

Страница 24: ...tank Smaltato anodo Mg Smaltato anodo Mg Insulation thickness mm 40 85 40 85 Degree of protection IP24 IP24 Max connected load W 2350 2350 Voltage 230 V 50 Hz 230 V 50 Hz Number and power of heating elements W 2 x 1000 2 x 1000 Electricity protection A 16 16 Adjusted water temperature C 55 55 Maximum temperature HP el heater C 55 75 55 75 Legionella control programme C 70 70 Temperature range of i...

Страница 25: ...147 W 19 20 Sound power Sound pressure at 1m dB A 51 39 5 51 39 5 Air connections mm m ø125 150x70 10 ø125 150x70 10 Working Air Flow m3 h 100 230 100 230 Max acceptable pressure drop in the pipeline volumetric flow rate of air 150 m3 h Pa 90 90 Heating of water to 55 C at inlet air temperature of 15 C 74 humidity and inlet temperature of water of 10 C in accordance with the EN16147 standard Heati...

Страница 26: ...t L of the Building Regulations Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is the hot water temperature at the nearest outlet C All appropriate pipes have been insulated up to 1 metre or the point where they become concealed Yes UNVENTED SYSTEMS ONLY Where is the pressure reducing valve situated if fitted What is the...

Страница 27: ...hone No Comments Signature SERVICE 05 Date Engineer name Company name Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Comments Signature SERVICE 09 Date Engineer name Company name Telephone No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Comments Signature SERVICE 04 Date Engineer name Company name Telephone No Comments Signatur...

Страница 28: ...Cool Energy Holding Ltd 163 Cleethorpe Road Grimsby DN31 3AX Email 30TUsales coolenergyshop comU30T 30Twww coolenergyshop com30T ...