background image

INSTRUCTIONS FOR THE INSTALLER

GB

1. LAWS, RULES

2 GENERAL NOTES

3. POSITIONING

Caution

4. MOUNTING THE HOOD

Important !

• You are advised to fit the variable speed unit which will cover all power consumption up to 900 W.

The extraction hoods with inlet fan  220V (1) 50 Hz;

The installation must be carried out by professionally qualified persone in accordance with local standards and 
regulations in force.

• The extraction hoods are normally supplied complete with filter and panels . In any models there is illumination lamps 
220V (1) 50 Hz but without the extractor unit with the exception of the following:

• Remove the protective film from the external surfaces slowly without tearing it, as glue can remain on the outer 
casing of the appliance. Should this happen, remove the glue using a suitable solvent.

• There are two types of filter which can fitted to the extraction hoods:
- standandard type: stainless steeel filter 400x500x25 mm dim. 

- optional type stainless steeel filter 400x500x25 mm dim. DIN 18869-5

- tap drain 

• The positioning of the extraction hood must respect the following:
- It must be connected to an efficient air extraction system or directly to the outside;

- The ideai height measured from the floor is 2000 mm;

- The perimeter of the hood must protrude by at least 20 cm with respect to the underlying appliance these distances 
are valid unless the locai standards and regulations specify other dimensions.

The wall mounted hoods Cubic and Line series MUST BE  assemblea with the filters fitted to the wall side; while the 
“Oven and Dishwasher type models ARE TO BE assemblea with the filters fitted towards the inside.

The hood can be mounted using the eyebolts and expansion bolts .If the ceiling has been constructed using hollow 
bricks then ampoule type chemical rawlplugs can be used. To fit the extraction hood proceed as follows:

Make sure that the ceiling or wall is able to support the weight of the hood; otherwise they will trave to be reinforced.

4.1 Mounting  the hood using expansion bolts

To mount the hood proceed as follows:
- Mark the positions, on the wall or ceiling, where the expansion bolts are to be fitted and drill the holes using a Ø 14 
mm drill bit.
- Insert the M8 expansion bolts and tighten the lock nuts.
- Cut the threaded bar, wire cables or chains to measure and hang the extraction hood from the ceiling as follows:
a) Mounting  the hood using threaded  bars (fig. 1)
- Screw the threaded bar directly into the expansion bolt in th ceiling
- Fasten down using the relative nuts and washers and fit the bar covers.
- Lift up the hood and position it in such a way that the threaded bars fit perfectly into the holes on the upper part of the 
hood then fasten down using the relative nuts and washers.
b) Mounting  the hood using wire cables  or chains (fig. 2).
- Screw the Ø 8 MA eyebolts into the expansion bolts in the ceiling
- Fit a second series of eyebolts into the holes on the upper part of the hood;
- Connect each pair of eyebolts using chains.

GRX 1

16 /  18

Содержание 333014 (BKP1418ILL)

Страница 1: ...ine Marke der PENTAGAST eG Ruhrstrauch 4 D 36100 Petersberg Tel 49 0 66 1 93 48 3 0 Fax 49 0 66 1 93 48 3 25 info pentagast de www pentagast de L ftung Wandhaube in Kastenform Artikel Nr 333014 BKP141...

Страница 2: ...LLUNGS GEBRAUCHS UND INSTANDHALTUNGS ANWEISUNGEN pagina 10 14 INSTRUCTIONS FOR INSTALLATION ADJUSTMENT USE AND MAINTENANCE pagina 15 18 Read the manual thoroughly and keep it in a safe place throughou...

Страница 3: ...LAZIONE 1 CONFORMIT ALLE NORME E LEGGI pagina 6 2 GENERALITA pagina 6 3 POSIZIONAMENTO pagina 6 4 MONTAGGIO pagina 6 7 5 COLLEGAMENTI ELETTRICI pagina 7 6 VERIFICA FUNZIONALE pagina 8 ISTRUZIONI PER L...

Страница 4: ...8 Mutter M8 Nut B Golfare Ringschraube Eye bolt C Barra filettata M8 Threaded bar M8 C Moschettone Haken Joint D Tubo copri barra Inox 12 mm Schutz Stahlrohr f r Stab 12 mm D Tenditore Spanner Eccentr...

Страница 5: ...SCHEMI DI INSTALLAZIONE INSTALLATIONSCHEMEN I T Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 GRX 1 4 18...

Страница 6: ...SCHEMI DI INSTALLAZIONE INSTALLATIONSCHEMEN I T Fig 9 Fig 10 GRX 1 5 18...

Страница 7: ...rico grassi Su richiesta fornibile un filtro a labirinto in acciaio inox 304delle stesse dimensioni conforme alla normativa DIN 18869 5 La cappa deve essere posizionata nel rispetto dei seguenti param...

Страница 8: ...are a pressione il tassello attendere che il componente abbia fatto presa circa 1 ora con temperatura ambiente a 20 C e poi completare il montaggio avvitando sul tassello la barra filettata o la fune...

Страница 9: ...e andr posizionato in un punto facilmente accessibile comodo per la manovra e lontano da fonti ci calore in modo da favorire lo smaltimento del calore da esso prodotto Deve essere collegato al motore...

Страница 10: ...sempre l alimentazione elettrica prima di eseguire qualsiasi operazione di pulizia o di manutenzione Ogni settimana togliere i filtri antigrasso dalla cappa ad esclusione delle cappe che non prevedon...

Страница 11: ...N 1 GESETZLICHE VORSCHRIFTEN UND TECHNISCHE NORMEN Seite 11 2 ALLGEMEIN Seite 11 3 AUFSTELLUNG Seite 11 4 MONTAGE Seiten 12 5 ELEKTRISCHER ANSCHLUSS Seite 13 6 FUNKTIONSPR FUNG DER ANLAGE Seite 13 GEB...

Страница 12: ...ter sind von zwei verschiedenen Typen voneinander komplett austauschbar Der Standard Filter ist ein Edelstahl 304 Labyrinth Filter Abmessungen 400x500x25 Auf Anfrage kann ein anderer Edelstahl 304 Lab...

Страница 13: ...und die Dunstabzugshaube an die Decke h ngen Wie folgt vorgehen a Montage mit Gewindest be Fig 1 Ger t so einh ngen da es fest an den vorgesehenen Aufh ngungen einrastet und mit Unterlegsscheibe und M...

Страница 14: ...dem Fachpersonal die Anschl sse zug nglicher zu machen Alle Dunstabzugshauben bis zu den Modellen f r fen und Sp hlmaschinen k nnen mit Beleuchtung ausgestattet werden oder sind mit Beleuchtung ausges...

Страница 15: ...chbesitzer auf Bei St rungsf llen ist das Ger t vom Netz zu trennen Reparaturen darf nur eine konzessionierte Fachkraft durchf hren Verlangen Sie Original Ersatzteilen Die Nicht Erf llung obengenannte...

Страница 16: ...3 4 INSTALLER INSTRUCTION 1 LAWS REGULATIONS page 16 2 GENERAL NOTES page 16 3 POSITIONING page 16 4 MOUNTING page 16 17 5 WIRING page 17 6 TESTING page 17 OPERATING INSTRUCTION 1 GENERAL INSTRUCTION...

Страница 17: ...s specify other dimensions The wall mounted hoods Cubic and Line series MUST BE assemblea with the filters fitted to the wall side while the Oven and Dishwasher type models ARE TO BE assemblea with th...

Страница 18: ...re of 20 C and then screw the threaded bar or eyebolt into the rawlplug Note when using the chemical method follow the instructions supplied by the manufacturer 4 3 Fitting wall mounted hoods fig 3 4...

Страница 19: ...ndards of hygiene required by modem kitchens Before commencing any clearing or maintenance operations make sure that the power is switched off at the mains Remove the filters from the hood every week...

Страница 20: ......

Отзывы: