background image

01

CARBFILT4 (UK & IE) 

 or CARBFILT4CL (FR)

(UK + IE)

VENT PACK 2

24

Installation

You can choose two type of installation:

- Ducted option

- Recirculation option

Содержание 5052931055 715

Страница 1: ...CLGCH60 C CLGCH90 C Cooker Hood v3 CLGCH60 C CLGCH90 C Barcode 5052931055715 5052931055722 GB IE ...

Страница 2: ... 01 x 1 04 x 1 05 x 1 02 x 1 03 x 1 06 x 1 07 x 1 ...

Страница 3: ...1 1 12 x 4 13 x 6 3 9 x 32mm 08 x 4 10 x 1 09 x 4 11 x 6 14 x 4 3 4 x 10mm ...

Страница 4: ...GB IE Cooker Hood 05 Installation 23 CLGCH60 C CLGCH90 C 4 ...

Страница 5: ... start 07 Safety 09 In more detail 11 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information Guarantee CE Declaration of conformity 12 12 13 16 17 17 20 22 Appendix 23 Installation GB IE ...

Страница 6: ...6 Getting Started Getting started GB IE Before you start 07 Safety 09 ...

Страница 7: ...k that it is not damaged If in doubt do not use the appliance but contact Customer Services on 0844 800 1128 UK 01 4475261 Ireland and 01 56 48 02 60 France Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product or handling to prevent personal injury or damage to the product ordering replacement parts If you sell the appliance give it a...

Страница 8: ...mm CARBFILT4 UK IE OR CARBFILT4CL FR SELF ADHESIVE ALUMINIUM TAPE Accessories not supplied Recirculation Extraction CARBON FILTER ORDERING HOTLINE 0844 800 1128 UK 01 4475261 IE Ø125mm or Ø150mm VENT PACK 2 UK IE 8 Getting started GB IE ...

Страница 9: ...unless they have been given supervision and instruction concerning the use of the appliance by a person responsible for their safety Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules An all pole disconnection switch having a contact separation of at least 3 mm in all poles should be connected in fixed wiring Do not allow the electric cables to tou...

Страница 10: ...ion must be complied with Warning before connecting the hood switch off the electricity supply and check that the supplied voltage and frequency coincide with that indicated on the appliance nameplate Warning the hood may stop working during an electrostatic discharge e g lightning This involves no risk of damage Switch off the electricity supply to the hood and reconnect after one minute To avoid...

Страница 11: ... detail In more detail GB IE Product functions 12 Operation 12 Care and maintenance 13 Troubleshooting 16 Recycling and disposal 17 Technical and legal information 17 Guarantee 20 CE Declaration of conformity 22 ...

Страница 12: ...ppliance at the switched fused connection unit The appliance is ready for operation functions Five button panel Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extractor fan speed button speed 2 Extractor fan speed button speed 3 To obtain the best results from your cooker hood it is recommended that you leave it switched on for 15 minutes after Product Functions Operation...

Страница 13: ...ng always switch off the electricity supply before carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement The Bulb may be hot leave it 10 minutes before replacement FUSE OFF 13 In more detail GB IE ...

Страница 14: ...Care and maintenance 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT4 UK IE OR CARBFILT4CL FR CLICK 14 In more detail GB IE ...

Страница 15: ...osition the filters vertically to improve the cleaning process Active charcoal filters replace every 3 months Important increase the filter cleaning replacement frequency if the hood is used for more than 2 hours a day Always use genuine filters from the manufacturer Care and maintenance FUSE OFF Warning Always switch off the electricity supply before performing maintenance work In the event of a ...

Страница 16: ...nection loose Check power supply Suction performance reduced Speed may be too low Select a higher speed Distance between the cooker hood and the hob is too great Readjust the distance to Gas hobs 750mm Electric hobs 650mm Aluminium grease filter is dirty Clean filters see care and maintenance Top vent might be obstructed CLVH60SS C CLVH60W C Clear any obstruction Optional vent kit might be twisted...

Страница 17: ...s product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if this product is not handled correctly To receive more detailed information about recycling this product contact your local government domestic waste disposal services or the outlet where the product was bought Technical and legal information The Manufa...

Страница 18: ... FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The installer must ensure that the correct electrical connection has...

Страница 19: ...he cooker hood WARNING THIS APPLIANCE MUST NOT BE EARTHED The appliance is supplied with a 2 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minimum contact gap on each connector For UK only A Switched Fused Connection Unit to BS 1363 Part 4 is recommended The fuse must be rated at 3 Amps The wires in the mains lead are coloured in accordance ...

Страница 20: ...he GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replacement appliance Should any person other than an authorized engineer modify or attempt to repair the appliance then the warranty will be invalid The guarantee applies to the UK mainland Scotland Ireland ROI and France but is not transferrable between EU countries This guarantee...

Страница 21: ...er installer to remove and reinstall the appliance to facilitate the repair This Guarantee does not affect your statutory rights The guarantee is offered by GAA Ltd 1301 1303 Lu Plaza 2 Wing Yip St Kwun Tong Kowloon Hong Kong Customer Service To arrange an in guarantee service call please contact customer services on the following numbers UK Northern Ireland T 0844 8001128 E uksupport apelson co u...

Страница 22: ...ED Standard EN 60335 1 Safety of household and similar electrical appliances Standard EN 60335 part 2 31 particular requirements for range hoods Standard EN 55014 Limits and methods of measurement of radio disturbance Standard EN 61000 3 2 Electromagnetic compatibility limits for harmonic Standard EN 61000 4 5 Electromagnetic compatibility EMC APPLIED INTERNATIONAL TECHNICAL STANDARDS AND SPECIFIC...

Страница 23: ...23 Appendix Appendix FR Installation ...

Страница 24: ...01 CARBFILT4 UK IE or CARBFILT4CL FR UK IE VENT PACK 2 24 Installation You can choose two type of installation Ducted option Recirculation option ...

Страница 25: ...0mm 170 122 34 170 90 Gas Electric MAX 935 25 Mark on the kitchen wall the holes to fix the cooker hood The Wall Plugs supplied are suitable for solid walls only When fixing to any other type of wall use suitable alternative fixings ...

Страница 26: ...oles insert the wall plugs in all 6 holes Insert the screws in the middle 2 holes in fig 03 Maximum gap between top 2 holes and middle 2 holes can be no more than 935mm dependant on ceiling height 13 x 2 03 2mm 2mm 2mm 11 13 03 13 26 ...

Страница 27: ...05 06 27 Remove the aluminium Filter 10 08 x 4 09 x 4 12 x 4 ...

Страница 28: ...07 08 28 Replace the aluminium Filter 13 x 2 ...

Страница 29: ...09 10 07 14 06 14 x 2 06 07 29 Fix the Ducting Tube 125 or 150 using tape or clamp Vent Pack 2 UK IE x 1 Fix the Collar and the reducer if required ...

Страница 30: ...11 12 30 02 14 02 x 1 14 x 2 ...

Страница 31: ...13 31 For recirculating option refer to Care and maintenance section Note For electrical connection see Technical and legal information section ...

Страница 32: ...B Q plc Chandlers Ford Hants SO53 3LE United Kingdom 0845 609 6688 www diy com Castorama Parc d Activités B P 101 59175 Templemars France 0 810 104 104 www castorama fr GB IE FR ...

Отзывы: