6 Moving and setting up the appliance
ConvoVent 4 / ConvoVent 4+
44
Item Name
Quantity
1
Fine particle filter
1
2
ConvoVent 4+ case
1
3
Mist collector
3
4
Baffle filter
2
5
Ventilation port on 10.10/10.20/20.10/20.20 1
6
Ventilation port on 6.10 or 12.20
1
7
Fixing bracket with two screws M5x12 DIN 7985
1
8
Right-angled pipe, ConvoVent 4/4+ for STK
1 (STK 6.10/10.10)
2 (STK 6.20/10.20)
9
Mains supply cable, 3-core, with cable gland
1 (6.10/10.10/20.10)
2 (6.20/10.20/12.20/20.20)
10
Control cable fitted with X38 connector
1 (6.10/6.20/10.10/10.20/12.20/20.10/20.20)
2 (STK 6.10/10.10 / STK 6.20/10.20)
11
Self-adhesive tie-wrap anchor with tie-wrap
1
Tools required
Phillips screwdriver
Requirements
Check that the following requirements have been met:
The appliance is disconnected from the power supply and protective measures taken to ensure the
power cannot be switched on again.
The left cover has been removed.
The installation kit components have been removed from the packaging and the contents checked to
ensure that all parts are present.
There are up to four people or suitable equipment available at certain times for lifting the hood.