6 Moving and setting up the appliance
ConvoVent 4 / ConvoVent 4+
40
6.1 Requirements for the installation location
Minimum clearances
The following table shows the required minimum clearances from the wall and other appliances:
Position Minimum
clearance
Minimum top clearance
500 mm
Minimum side clearance (left-hand
side)
100 mm
Minimum clearance to rear /
right-hand side
50 mm
Supporting surface
The supporting surface must have the following properties:
The supporting surface must be flat and horizontal.
The supporting surface must be able to bear the weight of the appliance including the hood and
maximum loading weight.
When using condensation hoods on stacking kits, the stacked combi steamers must not sit at a tilt of
greater than 5° (uneven floor): risk of toppling over.
Conditions in the surrounding environment
If other appliances are present in the same room that use an open extractor, special care is needed to
prevent the exhaust gases being drawn in.