7.2 Procedure for Placing the Unit into Operation
Checks before placing the unit into operation
Before putting the combi oven into operation, check whether the prerequisites below are being met:
■
The unit does not have any obvious damage.
■
The unit has been set up in such a way that it will not shift or topple over; the requirements con‐
cerning the location and the unit's surroundings are met (please refer to the 'Setup' on page 30).
■
Protective films, cardboard, securing devices for shipping, etc., have been removed completely.
■
There is nothing being stored inside the oven cavity and there is nothing inside the oven cavity oth‐
er than required cooking accessories (food containers, for example).
■
The unit has been installed as per the specifications in the 'Installation' on page 40 section.
■
The supply lines installed for electrical power, water, wastewater, and cleaning agents do not have
any obvious damage, have a secure fit, are not dripping anywhere, and appear to be safe and fully
functional after a visual inspection.
■
The unit has been subjected to an individual electric inspection (see below).
■
All safety guards and devices are in their intended place and are working properly.
■
All warning labels are at their intended location.
■
The unit and the accessories being used must have been cleaned properly.
Do not place the unit into operation unless all specified prerequisites are met.
Individual electric inspection
An individual electric inspection includes the following three steps:
■
Inspection: Visual inspection for damage and improper use
■
Measurement: Measurements performed as per generally accepted standards and practices
(equipment grounding conductor resistance, insulation resistance, equipment grounding conductor
current / leakage current)
■
Testing: Functional test
The individual electric inspection must be repeated at regular intervals as required by law.
Preparing to place the unit into operation
1.
Bring the ambient temperature to the permissible operat‐
ing temperature.
2.
Turn on the circuit breaker.
3.
Open the water supply.
4.
Check to make sure that the following are installed prop‐
erly in the right position:
■
Suction panel
■
Racks
5.
Turn the combi oven on.
6.
Set the following:
■
Date
■
Time
■
Language
7 Placing into operation