Using the two screws and plastic wall plugs (all supplied), attach the 
bracket to the wall. 

 

 

Line up the slot of the backet 

and the detector. Push the 
detector onto    the mounting 
bracked and turn it clockwise 
to fix it    into place. Pull 
outward on the detector to 
make sure it is securely 

attached to the mounting 
bracket. 

 

 

Do not 

insert the battery at this stage (9V). Please follow the steps of 

the next chapter before you insert the battery. 

 

 

How to install the battery: 

 

 

The smoke detector requires an alkaline battery 

 

 

Match terminals on the end(s) of the battery with opposite terminal 
connectors on the detector. Be sure to insert the alkaline battery in 

the position shown on the detector. 

 

 

When terminals are properly matched, push battery firmly in until it 
snaps and cannot be shaken loose. 

 
 

The smoke detector will not work until you insert the battery 
properly! 

 

 

Содержание Type 3

Страница 1: ...Detector Type 3 Operating Instructions Version 1 0 For Marmitek alarm installations of the types Homeguard MS8000 Security System MS9470 Security System MS9770 Protector28 Security System Base Station...

Страница 2: ...erpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information i...

Страница 3: ...nce references 5 4 Installation places 5 5 Installation 8 6 Registering the smoke detector with the base stations of the types MS9470 MS9770 SC2700 SC2800 10 7 Registering the smoke detector with the...

Страница 4: ...directly on the receiver The development of smoke causes the light to be dispersed by smoke particles and picked up by the receiver In contrast to many products on the market no radioactive substance...

Страница 5: ...etectors should be installed in accordance with the NFPA Standard 74 National Fire Protection Association Batterymarch Park Quincy MA 02169 In principle it is advisable to install several smoke detect...

Страница 6: ...Page 6 of 12 Recommended best and acceptable locations to mount smoke detectors Locations for placing smoke detectors for single residence with only one sleeping area...

Страница 7: ...Page 7 of 12 Locations for placing smoke detectors for single floor residence with more than one sleeping area Arrangement in a building with many floors...

Страница 8: ...ge metal objects as they can affect the radio range 5 Installation Please follow these steps to install the Convia smoke detector At the place where you are going to install the detector draw a horizo...

Страница 9: ...ot insert the battery at this stage 9V Please follow the steps of the next chapter before you insert the battery How to install the battery The smoke detector requires an alkaline battery Match termin...

Страница 10: ...e detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base station emits a short signal tone as confirmation of reception 4 If you are using...

Страница 11: ...lace the battery 9V in the correct polarity in the battery holder of the smoke detector The smoke alarm sends a radio signal to the base station The LED on the sensor illuminates briefly the base stat...

Страница 12: ...ted on the ceiling and turned clockwise to the stop 9 Convia smoke detector technical data Frequency 433 92 MHz Modulation AM Range 30 to 50 meters free field Alarm 85 dB Power supply 9V Blockbattery...

Отзывы: