Never try to dismantle the air conditioner yourself.

Problem

Check

The air conditioner does
not run.

Is the air conditioner plugged in ?

Is there a power failure ?

Is the "WATER FULL" error code

E2

flashing?

Drain the tank as shown (Fig 16).

Is the room temperature below the set temperature ?

The air conditioner has little
effect (firstly ensure that the
room being cooled is not too
large for the stated capacity
of the air conditioner).

Is there direct sunshine ? Remember to close
curtains or blinds.

Are windows or doors open ?

More people in the room will generate more heat.

Is there something in the room producing excessive
heat ?

Is the exhaust fitted correctly or obstructed ? All
exhaust air needs to be completely removed from
the room.

The air conditioner is not as
cool as it once was.

Is the filter dusty or dirty, restricting the airflow ?

Is the air inlet or outlet blocked ?

Is the room temperature below the set temperature ?

The air conditioner is too
noisy.

Is the air conditioner positioned unevenly, so as to
create vibration ?

Is the floor beneath the air conditioner uneven ?

It is possible that the overheat protection for the
compressor is on. Wait for it to reset.

Note: when changing between different modes
(cooling to fan or heating mode etc) the compressor
will turn off. A 3 minute delay will occur before the
compressor will turn on again.

The compressor will not run.

In case of problems that cannot be fixed by using the above guide,

or if service on your air conditioner is required, please contact your

dealer or designated service agent.

TROUBLESHOOTING

11

Содержание ClimateMaster CM9RW

Страница 1: ...Instruction Manual ClimateMaster CM9RW ClimateMaster Portable Refrigerated Air Conditioner...

Страница 2: ...cts must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment Please read these instructions prior to using the appliance and save the...

Страница 3: ...ble for their safety Children should be supervised to ensure that they do not play with the appliance Do not place anything through the ventilating slots Your Convair cooler is a portable air conditio...

Страница 4: ...ety cont Caution before connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the back of...

Страница 5: ...peed On Off Timer OSC Remote Sensor Control panel Air Filter Air Intake Power cord Air Intake side panel Exhaust Air Outlet Drain Exhaust Hose Window Kit Exhaust Fitting cooler end Exhaust Fitting win...

Страница 6: ...d fit the adjustable window attachment Extend the attachment as required and lock into place with the wing nut Ensure the outlet is not obscured The window attachment can be installed horizontally or...

Страница 7: ...r Timer Set button Horizontal Swing Vane button Vertical Swing Vane button Mode Select button Press to increase to decrease the set temperature or timer Press to turn the air conditioner on and off Pr...

Страница 8: ...batteries If there is no display or only part display remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure...

Страница 9: ...has cycled off Auto mode Cooling mode Dry mode Fan mode automatic selection of operating mode refrigerated cooling refrigerated moisture removal from the air Fan only operation no cooling r s The set...

Страница 10: ...adjust the time in 0 5 hour increments from 0 5 12 hrs Fig 14 shows the cooler will turn off after 2 5 hrs When the air conditioner is working only the TIMER OFF can be set When the air conditioner i...

Страница 11: ...in hours will be displayed Adjust by pressing the TEMP TIMER button to increase or decrease in 0 5 hr increments To cancel the TIMER change the SET TIME to 0 0 h after 2 seconds the SET TIME will dis...

Страница 12: ...ioner without the filter Use a soft damp cloth to wipe the body clean Never use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These substances could po...

Страница 13: ...t air needs to be completely removed from the room The air conditioner is not as cool as it once was Is the filter dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room...

Страница 14: ...ir Flow Volume m hr 3 Noise Level Sound Pressure dB A Power Supply Input Power Watts Input Current Amperes Fuse Type Refrigerant Type Charge kg High Side Pressure Maximum MPa Low Side Pressure Maximum...

Страница 15: ...NOTES 13...

Страница 16: ...t is the policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specif...

Отзывы: