6.1.5
Linear encoders
The following parameter set-up should be followed when configuring a linear encoder.
Linear encoders, Ab, SC, Ab.SErvo, SC.SErvo, SC.HiPEr, SC.EndAt, SC SSI, EndAt, SSI
Before power-up
Ensure:
•
Feedback device is connected
•
Drive secure disable is not given (terminal 31)
Power-up drive
Ensure:
•
Drive displays “inh”
•
If the drive trips refer to Chapter 10
Slot identification
Identify:
•
Identify slot and associated menu, 15, 16, or 17
Select Solutions
Module
Enter
:
•
Speed feedback selector Pr
3.26
1
: Slot 1,
2
: Slot 2,
3
: Slot 3
Set-up encoder
power supply
Enter
:
•
Encoder power supply Pr
x.13
0
: 5v,
1
: 8v,
2
:15v
Set-up encoder
type
Enter
:
•
Encoder Type Pr
x.15
0
(Ab),
6
(SC),
3
(Ab.SErvo),
12
(SC.SErvo),
7
(SC.HiPEr),
9
(SC.EndAt),
11
(SC.SSI),
8
(EndAt),
10
(SSI)
•
SSI encoder format Pr
x.18
(
0
Gray code,
1
Binary format)
Auto configuration
Enter:
It is possible for the drive to set-up Pr
x.09
, Pr
x.10
, Pr
x.11
automatically see Pr
x.18
Set-up encoder
lines per
revolution
•
Equivalent lines per revolution Pr
x.10
Calculate according to motor pole pitch and encoder resolution as follows
Pr
x.10
= Motor pole pitch / encoder resolution
•
Line per revolution divider Pr
x.46
The equivalent lines per revolution Pr
x.10
is divided by the value in Pr
x.46
. This can be used
when an encoder is used where the number of lines or sine waves per pole is not an integer
e.g. 128.123 lines per rev = 128.123 in Pr
x.10
and 1000 in Pr
x.46
giving 128123/1000 =
128.123.
Encoder comms
•
Define linear encoder Pr
x.16
= 0
•
Encoder comms baud rate Pr
x.14
(EndAt, SSI)
•
Encoder comms resolution Pr
x.11
Pr
x.11
must be set to the number of comms bits used to represent the whole encoder
position in the comms message
Encoder turns Pr
x.09
When a linear encoder is selected no mask is placed on the turns information in Pr
x.09
, this
parameter displays the turns information as a full 16bit value. Linear SinCos encoders are
normally specified with a length for each sine wave period and the length for the least
significant bit of the position in the comms message. Pr
x.09
should be set-up with the ratio
between these two lengths:
Pr
x.09
ratio = Length for a sine wave period
Length of the LS bit of the position in the comms message
Error detection
Ensure
:
The required error detection is set-up in Pr
x.17
Initialisation
Ensure
:
Position feedback is initialised Pr
x.45
A re-initialise can be carried out enabling Pr
3.47
When using the above incremental plus commutation, absolute encoders (Ab.SErvo,
SC.SErvo) Pr
x.46
lines per revolution divider should remain at 1 to ensure correct
operation.