M’Ax Advanced User Guide
28
Issue Number: 4
www.controltechniques.com
6
Menu 4 Parameters - Torque Control
Notes
Parameters 4.52, 4.53, 4.54: see section F.2 Adjusting the threshold for the motor thermal-overload alarm in the M’Ax User Guide.
Parameter 4.04: the range 0 ~ 620 represents 0 ~ 200% FLC
Parameter
Range(
ô
)
Default(
ð
)
Type
4.01 {0.07}
Motor current magnitude
0 ~ I
OL
A
RO
Uni
P
4.03
Torque demand
±200.0%I
T
A
RO
Bi
P
4.04
Current demand
0 ~ 620
RO
Uni
P
4.07 {0.18}
Symmetrical current limit Kc1
0 ~ 300.0% I
M
200.0
RW
Uni
4.08
Torque reference
±200.0%I
LIM
0.0
RW
Bi
4.09
Torque-reference offset
±200.0%I
LIM
0.0
RW
Bi
4.10
Torque-reference offset enable
0 ~ 1
0
RW
Bit
4.11
Torque mode selector
0 ~ 2
0
RW
Uni
4.12 {0.16}
Current-demand filter 1 cut-off frequency
0 ~ 1200Hz
500
RW
Uni
4.15
Motor - thermal time-constant
[SLM]
RO
Uni
4.23
Current-demand filter 2 cut-off frequency
0 ~ 1200Hz
500
RW
Uni
4.24
Symmetrical current limit Kc2
0 ~ 300.0% I
M
200.0
RW
Uni
4.26
Torque-compensation gain
0 ~ 5000 rads/s
RW
Uni
4.27
Current-demand filter 3 cut-off frequency
0 ~ 1200Hz
500
RW
Uni
4.28
Symmetrical current limit Kc3
0 ~ 300.0% I
M
200.0
RW
Uni
4.51
Reserved for internal system purposes
4.52
Motor thermal-overload trip level
0 ~ 125%I
M
110
RW
Uni
4.53
Symmetrical current limit after motor thermal-
overload trip
0 ~ 300%I
M
105
RW
Uni
4.54
Thermal-overload time to trip
0 ~ 200s
10
RW
Uni
4.55
SLM overheat threshold parameter
0 ~ 100
°
C
85
RW
Uni
4.56
Motor overload alarm level
0 ~ 100
70
RW
Uni
4.57
Motor overload alarm
0 ~ 1
RO
Uni
4.58
‘U’ phase current loop offset correction
0 ~ 65535
0
RW
Uni
4.59
‘V’ phase current loop offset correction
0 ~ 65535
0
RW
Uni
FLC
Full-load current (continuous-current rating of the
drive)
I
OL
Maximum overload current from the drive [2 x FLC]
I
M
Rated continuous motor-current (defined by the motor
via the SLM)
I
T
Maximum torque-producing current (derived from
[FLC x kT])
I
LIM
Value of the current limit that is obtained from the
setting of 4.07 Symmetrical current limit
LT
Trip level of the drive thermal-overload accumulator
n
MAX
Maximum speed of the motor (defined by the motor via
the SLM)
J
M
Motor inertia (defined by the motor via the SLM)
Содержание M'Ax
Страница 9: ... M Ax Advanced User Guide 6 Issue Number 4 www controltechniques com ...
Страница 47: ... M Ax Advanced User Guide 44 Issue Number 4 www controltechniques com ...
Страница 48: ... 45 M Ax Advanced User Guide www controltechniques com Issue Number 4 Figure 9 1 Menu 7 software diagram ...
Страница 49: ... M Ax Advanced User Guide 46 Issue Number 4 www controltechniques com ...
Страница 73: ... M Ax Advanced User Guide 70 Issue Number 4 www controltechniques com ...