• Operates on rotary or touch tone phone lines
• Programmable "call-to" number, up to twelve digits
• Three hour or fifteen minute call out frequency

General Description

• Programmable keypad
• Select switch for either alarm on temperature fall or

           alarm on temperature rise

Features

• Automatic reset
• Memory backup
• Two or eight ring call out
• Dial indicator light
• Remote sensor ("E" model only)
• FCC approved

The PhoneAlarm automatically dials a preprogrammed telephone
number and sounds an alarm tone when the temperature exceeds the
alarm setpoint.  The PhoneAlarm will redial until it is disabled.

Applications

Remote temperature alarm for monitoring of unoccupied buildings
and environments.  Applications include furnace failure (freeze
protection) air conditioning, agriculture, greenhouses, computer
rooms, etc.

Front

Side

3.25"

1.75"

Top

Rear

5.94"

Power requirements: 9 volt battery (not included)
Sensor: Fixed setpoint thermistor (12" lead on "E" model)
Accuracy: +3°F
Ambient temperature range: 20° to 140°F (-7 to 60°C)

Specifications

Humidity: 90% non-condensing
Weight: 7.5 oz
Agency approvals: FCC part 68
Ringer equivalence: 0.0B (ac)

Dimensions & Wiring

(151mm)

(83mm)

(44mm)

1724 Lake Drive West • Chanhassen, MN 55317 • 952-448-2217  FAX 952-448-1606 • Made in USA

  PA-1145-I / PA-1145-E

  PA-1185-I

PhoneAlarm

Innovative Technologies in Custom Electronic Design &  Manufacturing

Содержание PhoneAlarm Series

Страница 1: ...ntil it is disabled Applications Remote temperature alarm for monitoring of unoccupied buildings and environments Applications include furnace failure freeze protection air conditioning agriculture greenhouses computer rooms etc Front Side 3 25 1 75 Top Rear 5 94 Power requirements 9 volt battery not included Sensor Fixed setpoint thermistor 12 lead on E model Accuracy 3 F Ambient temperature rang...

Страница 2: ...y completed see B Programming above 2 Have someone available at call to location to answer when the PhoneAlarm calls 3 Press the pound key on the PhoneAlarm keypad until the red indicator light comes on then release 4 The PhoneAlarm will call the programmed number pulsing red indicator light confirms unit is dialing If the red indicator light does not pulse as unit is dialing repeat programming se...

Страница 3: ...d sound an alarm tone if the emergency condition still exists 2 If the call continues to ring beyond 16 rings temperature status has returned to normal Limited Warranty Modifications Custom Design Please use the following example when ordering PA 1145 I PA PhoneAlarm Temperature Setpoint 45 F 7 C 85 F 29 C I Internal Sensor E External Sensor Ordering Information Limited Warranty 1 Warrantor Dealer...

Страница 4: ...not conform to this Warranty the Product should be shipped or delivered freight prepaid to a Warrantor with evidence of original purchase If in any way you are not comfortable with the product or its Limited Warranty we encourage you return it unused FCC Regulations This equipment complies with Part 68 of the FCC Rules On the bottom of this equipment is a label that contains among other informatio...

Отзывы: