Necessary Materials  

In order to install your iDAccess Pro, you will need 
the  following  items:  drill,  wall  plugs  and  screws, 
screwdriver  or Philips, 12V power supply with at 
least 1A and an electronic lock.   

Installation 

For the correct operation of your iDAccess Pro, the 
following precautions should be taken: 

 

Install  in  a  place  that  is  not  exposed  to 
direct  sunlight  and  that  is  protected  from 
rain and other natural phenomena. 

 

Avoid metallic objects near the rear of the 
device in order not to impair the proximity 

reader’s range. In case this is not possible, 

use insulating spacers. 

 

Fix the bottom part of the wall support for 
iDAccess Pro at 1.2m from the ground. 

 

Before securing the device in place, ensure 
all  connecting  cables  are  correctly  routed 
towards the device. 

 
The  device  installation  process  is  simple  and 
should follow the diagram below: 

 

1.

 

For  greater  security  during  the  installation, 
place the External Access Module (EAM) in a 
secure region (internal area of the facility) 

2.

 

Use the reference pattern in the back of this 
guide to drill the 4 holes required to install the 
iDAccess Pro and fit in the wall plugs. 

3.

 

Connect the EAM to a +12V power source and 
to the lock, using the cables supplied. 

4.

 

Propose  a  4 

  way  cable  long  enough  to 

connect  the  EAM  to  the  iDAccess  Pro.  For 
distances  that  are  greater  than  5m,  use  a 
twisted  pair  cable.  Remember  to  use  the 
same pair for signals A and B. 

 

  The  EAM  is  responsible  for  powering 
iDAccess Pro. 

 
5.

 

Connect  the  wire  harness  provided  with 
iDAccess  Pro  to  the  4  wires  in  the  previous 
item. 

6.

 

Remove  the  wall  support  from  the  iDAccess 
Pro. 

7.

 

Screw the wall support with the wall plugs. 

8.

 

Connect  iDAccess  Pro  to  the  4-way  wire 
harness 

9.

 

Secure the iDAccess Pro on the wall support 
and  secure  it  in  place  with  the  screws 
provided  together  with  the  connection 
cables. 

Description 

of 

the 

Connection 

Terminals  

On your iDAccess Pro, there is a connector on the 
back of the device, besides the network connector 
(Ethernet). In the External Access Module (EAM) 
there  is  a  matching  connector  and  3  other 
connecting pins that will be used to connect locks, 
switches and scanners as explained ahead. 

iDAccess Pro:  4 - Pin Connector  

 

EAM: 2 - Pin Connector (Power Supply) 

  

 

 The connection to a +12V power supply with at 

least 1A is fundamental for the correct operation 
of the device.   

EAM: 4 - Pin Connector 

 

  

 

 

EAM: 5 - Pin Connector (Wiegand In/Out)  

 

 

 

 External card readers should be connected to 

Wiegand  WIN0  and  WIN1.  In  case  there  is  a 
control  board,  one  can  connect  the  Wiegand 
WOUT0 and WOUT1 outputs to the control board 
so that the user´s ID identified in the iDAccess Pro 
is transferred to it.  

EAM: 6 - Pin Connector (Door Control/Relay)  

 

 

 

 

 The push button and door sensor inputs can be 

configured as NO or NC and must be connected to 
dry  contacts  (switches,  relays  etc.)  between  the 
GND and respective pin.  

iDAccess Pro Settings 

The configuration of all the parameters of your new 
iDAccess  Pro  can  be  set  through  the  LCD  display 
(Graphic of user Interface 

 GUI) and/or through a 

standard internet browser (as long as the iDAccess 
Pro is connected to an Ethernet network and has 
this interface). 

In  order  to  configure  for  example  the  IP  address, 
subnet  mask  and  gateway,  through  the  touch 
screen,  follow  these  steps:   

Menu 

  Settings 

 

Network

. Update the information as you wish and 

connect the device to the network. 

Web Interface Settings  

First, connect the device directly to a PC using an 
Ethernet cable (cross or direct). Next, set a fixed IP 
on  your  computer  for  network  192.168.0.xxx 
(where xxx is different from 129 so that there is no 
IP conflict) and mask 255.255.255.0. 

To  access  the  device  settings screen,  open a  web 
browser 

and 

enter 

the 

following 

URL: 

http://192.168.0.129 

The login screen will be shown. The default access 
credentials are:  
 

• Username: 

admin

 

• Password: 

admin 

 

 Through the web interface you can change the 

device’s

  IP.  If  you  change  this  parameter, 

remember to write down the new value so that you 
can connect to the product again. 

Electronic lock types 

iDAccess  Pro,  through  the  relay  in  the  External 
Access Module, is compatible with almost all of the 
locks available in the market. 

Magnetic lock 

The magnetic or electromagnetic lock consists of 
a  coil  (fixed  part)  and  a  metal  part  (armature 
plate) which is attached to the door (mobile part). 
While  there  is  a  current  passing  through  the 
magnetic  lock,  the  fixed  part  will  attract  the 
mobile  part.  When  the  distance  between  these 
two parts is small, ie. when the door is closed and 
the dock is on top of the fixed part, the attraction 
force between the parts can reach over 1000kgf. 

Thus, the magnetic lock is normally connected to the 
NC  contact  of  the  activation  relay,  as  we  normally 
want  for  the  current  to  go  through  the 
electromagnet and, if we want the door to open, the 
relay must open and interrupt the current flow. 
 

In  this  guide,  the  magnetic  lock  will  be 
represented by: 

Power 

Supply

+12V

Relay, door sensor and push button

Wiegand input and output

Power supply for 
iDAccess Pro and

communication

2

5

6

4